Refine
Year of publication
Document Type
- Article (9)
- Conference Proceeding (5)
- Working Paper (2)
- Lecture (1)
- Report (1)
Language
- English (18) (remove)
Has Fulltext
- yes (18)
Is part of the Bibliography
- no (18)
Keywords
- Q-factor (1)
- electromagnetic field (1)
- measurement (1)
Institute
- Physik (18) (remove)
Mode propagation in an iris type accelerator section loaded with single heavily HOM-damped cells
(1994)
The wakefield effects in accelerator sections for future linear colliders will be reduced either by damping by detuning or by a combination of both. For the DESY/THD linac [1] it is forseen to employ heavily HOM-damped cells to provide a strong coupling to the TE/TM11-dipole passband as well as to the TM/TE11-dipole passband. For our experiments we have used wall-slotted damping cells. This leads to several problems concerning the propagation of fundamental and HOM-modes. Experimental investigations have been done. Results are presented.
To reach high luminosities in future linear colliders short range wakes havea to be controlled in the range of X-band frequencies or higher. Rectangular irises can be used to introduce strong focusing quadrupole-like rf-fields. Even circular irises in iris-loaded accelarator structures have the capability of focusing if the particle velocity differs from phase velocity. Theoretical investigations concerning the focusing strength to be expected are presented. Their applicability for linear colliders is discussed.
A new method for measuring quality factors in cavities is presented. This method is capable of measuring Q-factors in heavily damped as well as in undamped cavities. In addition, the possibility of separating overlapping modes and measuring their Q-factors is provided. Measurements on HOM (higher order mode) damped cavities for the DESY/THD linear collider project are presented
To preserve the required beam quality in an e+/e- collider it is necessary to have a very precise beam position control at each accelerating cavity. An elegant method to avoid additional length and beam disturbance is the usage of signals from existing HOM-dampers. The magnitude of the displacement is derived from the amplitude of a dipole mode whereas the sign follows from the phase comparison of a dipole and a monopole HOM. To check the performance of the system, a measurement setup has been built with an antenna which can be moved with micrometer resolution to simulate the beam. Furthermore we have developed a signal processing to determine the absolute beam displacement. Measurements on the HOM-damper cell can be done in the frequency domain using a network analyser. Final measurements with the nonlinear time dependent signal processing circuit has to be done with very short electric pulses simulating electron bunches. Thus, we have designed a sub nanosecond pulse generator using a clipping line and the step recovery effect of a diode. The measurement can be done with a resolution of about 10 micrometers. Measurements and numerical calculations concerning the monitor design and the pulse generator are presented.