Refine
Document Type
- Bachelor Thesis (1)
- Master's Thesis (1)
Language
- English (2) (remove)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2) (remove)
Keywords
- FRANZ (2) (remove)
Institute
- Physik (2) (remove)
As a part of this thesis, a Monte Carlo-based code has been developed capable of simulating the transition of proton beam properties to neutron beam properties as it occurs in the Li-7(p, n)Be-7 reaction. It is able to reproduce not only the angle-integrated energy distributions but it is also capable of predicting the angle-dependent neutron spectra as measured at Forschungszentrum Karlsruhe (Karlsruhe, Germany) and Physikalisch-Technische Bundesanstalt (Braunschweig, Germany). Since the code retains all three spatial dimensions as well as all three velocity dimensions, it provides very detailed information on the neutron beam. The resulting data can aid in many different aspects, for example it can be used in shielding construction, or for lithium target design. In this work, the code is used to predict the neutron beam properties expected at the Frankfurt Neutron Source at Stern-Gerlach-Zentrum (FRANZ) facility. For different proton beam energies, the neutron distribution in x/p_x, y/p_y, and z/p_z is shown as well as a Mollweide projection, which illustrates the kinematic collimation effect that limits the neutron cone opening angle to less than 180 degree.
The current performance of a 4π barium fluoride gamma detector consisting of 41 modules is evaluated. It will be used to measure neutron capture events in different samples that are exposed to a neutron beam that is expected to contain up to 10^7 neutrons/(cm^2 sec). The capture cross-sections acquired in this experiment will be relevant to a multitude of different areas, for example to s-process studies, or accelerator-driven systems. The detector array was re-mounted after having been moved from Karlsruhe to Frankfurt and in the course of this process, the detector modules have been checked for their current detection properties. Every module consists of a BaF2 crystal, a photomultiplier tube connected to the crystal by sillicon oil and a voltage divider to drive the PMT, so each of them is already an individual gamma detector. Using Cobalt-60 and Caesium-137 test sources the energy resolution and - more importantly - the time resolution of every module has been determined; the results are presented in this work and compared to previous data taken at the time the detector was built initially in the mid-1980s.