Refine
Document Type
- Article (22) (remove)
Language
- English (22)
Has Fulltext
- yes (22)
Is part of the Bibliography
- no (22)
Keywords
- Bone density (3)
- Computed tomography (3)
- Magnetic resonance imaging (3)
- Osteoporosis (3)
- Spine (3)
- Algorithms (2)
- Artificial intelligence (2)
- Multidetector computed tomography (2)
- Tomography (x-ray computed) (2)
- Age determination by skeleton (1)
Institute
- Medizin (22)
- Informatik und Mathematik (1)
Rationale and Objectives: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration.
Patients and Methods: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality.
Results: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0–93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC = 0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4).
Conclusion: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.
Highlights
• Early reconstruction of injured cruciate ligaments improves functional outcomes.
• Modern CT imaging can be used to rapidly identify patients with injury to the cruciate ligaments and streamline therapeutic pathways.
• Dual-energy CT demonstrates superior diagnostic accuracy compared to single-energy CT.
Abstract
Background: This study aimed to evaluate the clinical utility of modern single and dual-energy computed tomography (CT) for assessing the integrity of the cruciate ligaments in patients that sustained acute trauma.
Methods: Patients who underwent single- or dual-energy CT followed by 3 Tesla magnetic resonance imaging (MRI) or knee joint arthroscopy between 01/2016 and 12/2022 were included in this retrospective, monocentric study. Three radiologists specialized in musculoskeletal imaging independently evaluated all CT images for the presence of injury to the cruciate ligaments. An MRI consensus reading of two experienced readers and arthroscopy provided the reference standard. Diagnostic accuracy parameters and area under the receiver operator characteristic curve (AUC) were the primary metrics for diagnostic performance.
Results: CT images of 204 patients (median age, 49 years; IQR 36 – 64; 113 males) were evaluated. Dual-energy CT yielded significantly higher diagnostic accuracy and AUC for the detection of injury to the anterior (94% [240/255] vs 75% [266/357] and 0.89 vs 0.66) and posterior cruciate ligaments (95% [243/255] vs 87% [311/357] and 0.90 vs 0.61) compared to single-energy CT (all parameters, p <.005). Diagnostic confidence and image quality were significantly higher in dual-energy CT compared to single-energy CT (all parameters, p <.005).
Conclusions: Modern dual-energy CT is readily available and can serve as a screening tool for detecting or excluding cruciate ligament injuries in patients with acute trauma. Accurate diagnosis of cruciate ligament injuries is crucial to prevent adverse outcomes, including delayed treatment, chronic instability, or long-term functional limitations.
Highlights
• Assessment of coronary artery plaque burden according to the CAC-DRS Score correlated well with pulmonary involvement of SARS-CoV-2 pneumonia (min. r=0.81, 95% CI 0.76 to 0.86).
• Visual and quantitative CAC-DRS Score of coronary artery plaque burden provided independent prognostic information on all-cause mortality in patients with SARS-CoV-2 pneumonia (p=0.0016 and p<0.0001, respectively).
• Incorporating CAC-DRS Score and pulmonary involvement into clinical decision making revealed great potential to discriminate patients with fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89 to 0.97) and the need for intensive care treatment (AUC 0.801, 95% CI 0.77 to 0.83).
Purpose: To assess and correlate pulmonary involvement and outcome of SARS-CoV-2 pneumonia with the degree of coronary plaque burden based on the CAC-DRS classification (Coronary Artery Calcium Data and Reporting System).
Methods: This retrospective study included 142 patients with confirmed SARS-CoV-2 pneumonia (58 ± 16 years; 57 women) who underwent non-contrast CT between January 2020 and August 2021 and were followed up for 129 ± 72 days. One experienced blinded radiologist analyzed CT series for the presence and extent of calcified plaque burden according to the visual and quantitative HU-based CAC-DRS Score. Pulmonary involvement was automatically evaluated with a dedicated software prototype by another two experienced radiologists and expressed as Opacity Score.
Results: CAC-DRS Scores derived from visual and quantitative image evaluation correlated well with the Opacity Score (r=0.81, 95% CI 0.76-0.86, and r=0.83, 95% CI 0.77-0.89, respectively; p<0.0001) with higher correlation in severe than in mild stage SARS-CoV-2 pneumonia (p<0.0001). Combined, CAC-DRS and Opacity Scores revealed great potential to discriminate fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89-0.97), and the need for intensive care treatment (AUC 0.801, 95% CI 0.77-0.83). Visual and quantitative CAC-DRS Scores provided independent prognostic information on all-cause mortality (p=0.0016 and p<0.0001, respectively), both in univariate and multivariate analysis.
Conclusions: Coronary plaque burden is strongly correlated to pulmonary involvement, adverse outcome, and death due to respiratory failure in patients with SARS-CoV-2 pneumonia, offering great potential to identify individuals at high risk.
Rationale and Objectives: Bone non-union is a serious complication of distal radius fractures (DRF) that can result in functional limitations and persistent pain. However, no accepted method has been established to identify patients at risk of developing bone non-union yet. This study aimed to compare various CT-derived metrics for bone mineral density (BMD) assessment to identify predictive values for the development of bone non-union.
Materials and Methods: CT images of 192 patients with DRFs who underwent unenhanced dual-energy CT (DECT) of the distal radius between 03/2016 and 12/2020 were retrospectively identified. Available follow-up imaging and medical health records were evaluated to determine the occurrence of bone non-union. DECT-based BMD, trabecular Hounsfield unit (HU), cortical HU and cortical thickness ratio were measured in normalized non-fractured segments of the distal radius.
Results: Patients who developed bone non-union were significantly older (median age 72 years vs. 54 years) and had a significantly lower DECT-based BMD (median 68.1 mg/cm3 vs. 94.6 mg/cm3, p < 0.001). Other metrics (cortical thickness ratio, cortical HU, trabecular HU) showed no significant differences. ROC and PR curve analyses confirmed the highest diagnostic accuracy for DECT-based BMD with an area under the curve (AUC) of 0.83 for the ROC curve and an AUC of 0.46 for the PR curve. In logistic regression models, DECT-based BMD was the sole metric significantly associated with bone non-union.
Conclusion: DECT-derived metrics can accurately predict bone non-union in patients who sustained DRF. The diagnostic performance of DECT-based BMD is superior to that of HU-based metrics and cortical thickness ratio.
Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model.
Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
Objectives: To assess the impact of noise-optimised virtual monoenergetic imaging (VMI+) on image quality and diagnostic evaluation in abdominal dual-energy CT scans with impaired portal-venous contrast.
Methods: We screened 11,746 patients who underwent portal-venous abdominal dual-energy CT for cancer staging between 08/2014 and 11/2019 and identified those with poor portal-venous contrast.
Standard linearly-blended image series and VMI+ image series at 40, 50, and 60 keV were reconstructed. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of abdominal organs and vascular structures were calculated. Image noise, image contrast and overall image quality were rated by three radiologists using 5-point Likert scale.
Results: 452 of 11,746 (4%) exams were poorly opacified. We excluded 190 cases due to incomplete datasets or multiple exams of the same patient with a final study group of 262. Highest CNR values in all abdominal organs (liver, 6.4 ± 3.0; kidney, 17.4 ± 7.5; spleen, 8.0 ± 3.5) and vascular structures (aorta, 16.0 ± 7.3; intrahepatic vein, 11.3 ± 4.7; portal vein, 15.5 ± 6.7) were measured at 40 keV VMI+ with significantly superior values compared to all other series. In subjective analysis, highest image contrast was seen at 40 keV VMI+ (4.8 ± 0.4), whereas overall image quality peaked at 50 keV VMI+ (4.2 ± 0.5) with significantly superior results compared to all other series (p < 0.001).
Conclusions: Image reconstruction using VMI+ algorithm at 50 keV significantly improves image contrast and image quality of originally poorly opacified abdominal CT scans and reduces the number of non-diagnostic scans.
Advances in knowledge: We validated the impact of VMI+ reconstructions in poorly attenuated DECT studies of the abdomen in a big data cohort.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.
Low serum concentrations of the amino acid homoarginine (HA) are associated with increased cardiovascular mortality by incompletely understood mechanisms. This study sought to assess the influence of HA on cardiac remodeling in rats undergoing either transaortic banding or inhibition of nitric oxide synthesis by Nω-Nitro-L-arginine methyl ester hydrochloride (L-NAME). Male Wistar rats (n = 136) underwent sham operation (SH) or aortic banding (AB). Both groups were equally divided into 14 subgroups, receiving different doses of HA alone or in combination with lisinopril, spironolactone, or L-NAME for 4 weeks. HA treatment in AB animals resulted in a dose-dependent improvement of cardiac function up to a concentration of 800 mg·kg−1·day−1. Combining 800 mg·kg−1·day−1 HA with spironolactone or lisinopril yielded additional effects, showing a positive correlation with LV ejection fraction (+33%, p = 0.0002) and fractional shortening (+41%, p = 0.0014). An inverse association was observed with collagen area fraction (−41%, p < 0.0001), myocyte cross-sectional area (−22%, p < 0.0001) and the molecular markers atrial natriuretic factor (−74%, p = 0.0091), brain natriuretic peptide (−42%, p = 0.0298), beta-myosin heavy chain (−46%, p = 0.0411), and collagen type V alpha 1 chain (−73%, p = 0.0257) compared to placebo-treated AB animals. Co-administration of HA and L-NAME was found to attenuate cardiac remodeling and prevent NO-deficient hypertension following AB. HA treatment has led to a dose-dependent improvement of myocardial function and marked histological and molecular changes in cardiac remodeling following AB. Combining HA with standard heart failure medication resulted in additional beneficial effects boosting its direct impact on heart failure pathophysiology.
Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
Objectives: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging.
Methods: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard.
Results: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05).
Conclusions: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations.
Key Points
• Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference.
• Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series.
• Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.