Background: The most common technique used worldwide to quantify blood loss during an operation is the visual assessment by the attending intervention team. In every operating room you will find scaled suction canisters that collect fluids from the surgical field. This scaling is commonly used by clinicians for visual assessment of intraoperative blood loss. While many studies have been conducted to quantify and improve the inaccuracy of the visual estimation method, research has focused on the estimation of blood volume in surgical drapes. The question whether and how scaling of canisters correlates with actual blood loss and how accurately clinicians estimate blood loss in scaled canisters has not been the focus of research to date.
Methods: A simulation study with four “bleeding” scenarios was conducted using expired whole blood donations. After diluting the blood donations with full electrolyte solution, the sample blood loss volume (SBL) was transferred into suction canisters. The study participants then had to estimate the blood loss in all four scenarios. The difference to the reference blood loss (RBL) per scenario was analyzed.
Results: Fifty-three anesthetists participated in the study. The median estimated blood loss was 500 ml (IQR 300/1150) compared to the RBL median of 281.5 ml (IQR 210.0/1022.0). Overestimations up to 1233 ml were detected. Underestimations were also observed in the range of 138 ml. The visual estimate for canisters correlated moderately with RBL (Spearman’s rho: 0.818; p < 0.001). Results from univariate nonparametric confirmation statistics regarding visual estimation of canisters show that the deviation of the visual estimate of blood loss is significant (z = − 10.95, p < 0.001, n = 220). Participants’ experience level had no significant influence on VEBL (p = 0.402).
Conclusion: The discrepancies between the visual estimate of canisters and the actual blood loss are enormous despite the given scales. Therefore, we do not recommend estimating the blood loss visually in scaled suction canisters. Colorimetric blood loss estimation could be a more accurate option.
Background: Iron deficiency (ID) is one of the most common nutritional deficiencies in children worldwide and may result in iron deficiency anemia (IDA). The reticulocyte hemoglobin equivalent (Ret-He) provides information about the current availability of iron in erythropoiesis. This study aims to examine the validation of Ret-He as a screening marker for ID and IDA in children. Methods: Blood samples were retrospectively obtained from medical records. Anemia was defined according to the definition provided by the World Health Organization (WHO) for children. ID was defined by transferrin saturation (TSAT) < 20% and ferritin < 100 ng/mL. Children were classified into four groups: IDA, non-anemia iron deficiency (NAID), control and others. Results: Out of 970 children, 332 (34.2%) had NAID and 278 (28.7%) presented with IDA. Analysis revealed that Ret-He significantly correlates with ferritin (rho = 0.41; p < 0.001), TSAT (rho = 0.66; p < 0.001) and soluble transferrin receptor (sTfR) (rho = −0.72; p < 0.001). For ROC analysis, the area under the curve (AUC) was 0.771 for Ret-He detecting ID and 0.845 for detecting IDA. The cut-off value for Ret-He to diagnose ID was 33.5 pg (sensitivity 90.7%; specificity 35.8%) and 31.6 pg (sensitivity 90.6%; specificity 50.4%) to diagnose IDA. Conclusions: The present study demonstrates Ret-He to be a screening marker for ID and IDA in children. Furthermore, Ret-He can be used as a single screening parameter for ID and IDA in children without considering other iron parameters. Economically, the use of Ret-He is highly relevant, as it can save one blood tube per patient and additional costs.
Background: Acute bleeding requires fast and targeted therapy. Therefore, knowledge of the patient's potential to form a clot is crucial. Point-of-care testing (POCT) provides fast and reliable information on coagulation. Structural circumstances, such as person-bound sample transport, can prolong the reporting of the results. The aim of the present study was to investigate the diagnostic quality and accuracy between POCT INR diagnostics and standard laboratory analysis (SLA) as well as the time advantage between a pneumatic tube and a personal-based transport system. Methods: Two groups of haemorrhagic patients (EG: emergency department; OG: delivery room; each n = 12) were examined in the context of bleeding emergencies using POCT and SLA. Samples were transported via a pneumatic tube system or by a personal transport service. Results: INR results between POCT and SLA showed a high and significant correlation (EG: p < 0.001; OG: p < 0.001). POCT results were reported significantly more quickly (EG: 1.1 vs. 39.6 min; OG: 2.0 vs. 75.0 min; p < 0.001) and required less time for analysis (EG: 0.3 vs. 24.0 min; OG: 0.5 vs. 45.0 min; p < 0.001) compared to SLA. The time for transportation with the pneumatic tube was significantly shorter (8.0 vs. 18.5 min; p < 0.001) than with the personal-based transport system. Conclusion: The results of the present study suggest that POCT may be a suitable method for the emergency diagnosis and may be used as prognostic diagnostic elements in haemotherapy algorithms to initiate targeted haemotherapy at an early point in time.
Background: Extracorporeal life support (ECLS) has become an integral part of modern intensive therapy. The choice of support mode depends largely on the indication. Patients with respiratory failure are predominantly treated with a venovenous (VV) approach. We hypothesized that mortality in Germany in ECLS therapy did not differ from previously reported literature
Methods: Inpatient data from Germany from 2007 to 2018 provided by the Federal Statistical Office of Germany were analysed. The international statistical classification of diseases and related health problems codes (ICD) and process keys (OPS) for extracorporeal membrane oxygenation (ECMO) types, acute respiratory distress syndrome (ARDS) and hospital mortality were used.
Results: In total, 45,647 hospitalized patients treated with ECLS were analysed. In Germany, 231 hospitals provided ECLS therapy, with a median of 4 VV-ECMO and 9 VA-ECMO in 2018. Overall hospital mortality remained higher than predicted in comparison to the values reported in the literature. The number of VV-ECMO cases increased by 236% from 825 in 2007 to 2768 in 2018. ARDS was the main indication for VV-ECMO in only 33% of the patients in the past, but that proportion increased to 60% in 2018. VA-ECMO support is of minor importance in the treatment of ARDS in Germany. The age distribution of patients undergoing ECLS has shifted towards an older population. In 2018, the hospital mortality decreased in VV-ECMO patients and VV-ECMO patients with ARDS to 53.9% (n = 1493) and 54.4% (n = 926), respectively.
Conclusions: ARDS is a severe disease with a high mortality rate despite ECLS therapy. Although endpoints and timing of the evaluations differed from those of the CESAR and EOLIA studies and the Extracorporeal Life Support Organization (ELSO) Registry, the reported mortality in these studies was lower than in the present analysis. Further prospective analyses are necessary to evaluate outcomes in ECMO therapy at the centre volume level.
Purpose: Anaemia is one of the leading causes of death among severely injured patients. It is also known to increase the risk of death and prolong the length of hospital stay in various surgical groups. The main objective of this study is to analyse the anaemia rate on admission to the emergency department and the impact of anaemia on in-hospital mortality.
Methods: Data from the TraumaRegister DGU® (TR-DGU) between 2015 and 2019 were analysed. Inclusion criteria were age ≥ 16 years and most severe Abbreviated Injury Scale (AIS) score ≥ 3. Patients were divided into three anaemia subgroups: no or mild anaemia (NA), moderate anaemia (MA) and severe anaemia (SA). Pre-hospital data, patient characteristics, treatment in the emergency room (ER), outcomes, and differences between trauma centres were analysed.
Results: Of 67,595 patients analysed, 94.9% (n = 64,153) exhibited no or mild anaemia (Hb ≥ 9 g/dl), 3.7% (n = 2478) displayed moderate anaemia (Hb 7–8 g/dl) and 1.4% (n = 964) presented with severe anaemia (Hb < 7 g/dl). Haemoglobin (Hb) values ranged from 3 to 18 g/dl with a mean Hb value of 12.7 g/dl. In surviving patients, anaemia was associated with prolonged length of stay (LOS). Multivariate logistic regression analyses revealed moderate (p < 0.001 OR 1.88 (1.66–2.13)) and severe anaemia (p < 0.001 OR 4.21 (3.46–5.12)) to be an independent predictor for mortality. Further significant predictors are ISS score per point (OR 1.0), age 70–79 (OR 4.8), age > 80 (OR 12.0), severe pre-existing conditions (ASA 3/4) (OR 2.26), severe head injury (AIS 5/6) (OR 4.8), penetrating trauma (OR 1.8), unconsciousness (OR 4.8), shock (OR 2.2) and pre-hospital intubation (OR 1.6).
Conclusion: The majority of severely injured patients are admitted without anaemia to the ER. Injury-associated moderate and severe anaemia is an independent predictor of mortality in severely injured patients.
Background: paediatric patients are vulnerable to blood loss and even a small loss of blood can be associated with severe shock. In emergency situations, a red blood cell (RBC) transfusion may become unavoidable, although it is associated with various risks. The aim of this trial was to identify independent risk factors for perioperative RBC transfusion in children undergoing surgery. Methods: to identify independent risk factors for perioperative RBC transfusion in children undergoing surgery and to access RBC transfusion rates and in-hospital outcomes (e.g., length of stay, mortality, and typical postoperative complication rates), a monocentric, retrospective, and observational study was conducted. Descriptive, univariate, and multivariate analyses were performed. Results: between 1 January 2010 and 31 December 2019, data from n = 14,248 cases were identified at the centre. Analysis revealed an RBC transfusion rate of 10.1% (n = 1439) in the entire cohort. The independent predictors of RBC transfusion were the presence of preoperative anaemia (p < 0.001; OR = 15.10 with preoperative anaemia and OR = 2.40 without preoperative anaemia), younger age (p < 0.001; ORs between 0.14 and 0.28 for children older than 0 years), female gender (p = 0.036; OR = 1.19 compared to male gender), certain types of surgery (e.g., neuro surgery (p < 0.001; OR = 10.14), vascular surgery (p < 0.001; OR = 9.93), cardiac surgery (p < 0.001; OR = 4.79), gynaecology (p = 0.014; OR = 3.64), visceral surgery (p < 0.001; OR = 2.48), and the presence of postoperative complications (e.g., sepsis (p < 0.001; OR = 10.16), respiratory dysfunction (p < 0.001; OR = 7.56), cardiovascular dysfunction (p < 0.001; OR = 4.68), neurological dysfunction (p = 0.029; OR = 1.77), and renal dysfunction (p < 0.001; OR = 16.17)). Conclusion: preoperative anaemia, younger age, female gender, certain types of surgery, and postoperative complications are independent predictors for RBC transfusion in children undergoing surgery. Future prospective studies are urgently required to identify, in detail, the potential risk factors and impact of RBC transfusion in children.
Background: Approximately one in three patients suffers from preoperative anaemia. Even though haemoglobin is measured before surgery, anaemia management is not implemented in every hospital. Objective: Here, we demonstrate the implementation of an anaemia walk-in clinic at an Orthopedic University Hospital. To improve the diagnosis of iron deficiency (ID), we examined whether reticulocyte haemoglobin (Ret-He) could be a useful additional parameter. Material and Methods: In August 2019, an anaemia walk-in clinic was established. Between September and December 2019, major orthopaedic surgical patients were screened for preoperative anaemia. The primary endpoint was the incidence of preoperative anaemia. Secondary endpoints included Ret-He level, red blood cell (RBC) transfusion rate, in-hospital length of stay and anaemia at hospital discharge. Results: A total of 104 patients were screened for anaemia. Preoperative anaemia rate was 20.6%. Intravenous iron was supplemented in 23 patients. Transfusion of RBC units per patient (1.7 ± 1.2 vs. 0.2 ± 0.9; p = 0.004) and hospital length of stay (13.1 ± 4.8 days vs. 10.6 ± 5.1 days; p = 0.068) was increased in anaemic patients compared to non-anaemic patients. Ret-He values were significantly lower in patients with ID anaemia (33.3 pg [28.6–40.2 pg]) compared to patients with ID (35.3 pg [28.9–38.6 pg]; p = 0.015) or patients without anaemia (35.4 pg [30.2–39.4 pg]; p = 0.001). Conclusion: Preoperative anaemia is common in orthopaedic patients. Our results proved the feasibility of an anaemia walk-in clinic to manage preoperative anaemia. Furthermore, our analysis supports the use of Ret-He as an additional parameter for the diagnosis of ID in surgical patients.
Background: Point of care devices for performing targeted coagulation substitution in patients who are bleeding have become increasingly important in recent years. New on the market is the Quantra. It is a device that uses sonorheometry, a sonic estimation of elasticity via resonance, which is a novel ultrasound-based technology that measures viscoelastic properties of whole blood. Several studies have already shown the comparability of the Quantra with devices already established on the market, such as the rotational thromboelastometry (ROTEM) device.
Objective: In contrast to existing studies, this study is the first prospective interventional study using this new system in a cardiac surgical patient cohort. We will investigate the noninferiority between an already existing coagulation algorithm based on the ROTEM/Multiplate system and a new algorithm based on the Quantra system for the treatment of coagulopathic cardiac surgical patients.
Methods: The study is divided into two phases. In an initial observation phase, whole blood samples of 20 patients obtained at three defined time points (prior to surgery, after completion of cardiopulmonary bypass, and on arrival in the intensive care unit) will be analyzed using both the ROTEM/Multiplate and Quantra systems. The obtained threshold values will be used to develop a novel algorithm for hemotherapy. In a second intervention phase, the new algorithm will be tested for noninferiority against an algorithm used routinely for years in our department.
Results: The main objective of the examination is the cumulative loss of blood within 24 hours after surgery. Statistical calculations based on the literature and in-house data suggest that the new algorithm is not inferior if the difference in cumulative blood loss is <150 mL/24 hours.
Conclusions: Because of the comparability of the Quantra sonorheometry system with the ROTEM measurement methods, the existing hemotherapy treatment algorithm can be adapted to the Quantra device with proof of noninferiority.
Trial Registration: ClinicalTrials.gov NCT03902275; https://clinicaltrials.gov/ct2/show/NCT03902275
International Registered Report Identifier (IRRID): DERR1-10.2196/17206
Background: Anemia is the most important complication during major surgery and transfusion of red blood cells is the mainstay to compensate for life threating blood loss. Therefore, accurate measurement of hemoglobin (Hb) concentration should be provided in real-time. Blood Gas Analysis (BGA) provides rapid point-of-care assessment using smaller sampling tubes compared to central laboratory (CL) services. Objective: This study aimed to investigate the accuracy of BGA hemoglobin testing as compared to CL services. Methods: Data of the ongoing LIBERAL-Trial (Liberal transfusion strategy to prevent mortality and anemia-associated ischemic events in elderly non-cardiac surgical patients, LIBERAL) was used to assess the bias for Hb level measured by BGA devices (ABL800 Flex analyzer®, GEM series® and RapidPoint 500®) and CL as the reference method. For that, we analyzed pairs of Hb level measured by CL and BGA within two hours. Furthermore, the impact of various confounding factors including age, gender, BMI, smoker status, transfusion of RBC, intraoperative hemodilution, and co-medication was elucidated. In order to ensure adequate statistical analysis, only data of participating centers providing more than 200 Hb pairs were used. Results: In total, three centers including 963 patients with 1,814 pairs of Hb measurements were analyzed. Mean bias was comparable between ABL800 Flex analyzer® and GEM series®: - 0.38 ± 0.15 g/dl whereas RapidPoint 500® showed a smaller bias (-0.09 g/dl) but greater median absolute deviation (± 0.45 g/dl). In order to avoid interference with different standard deviations caused by the different analytic devices, we focused on two centers using the same BGA technique (309 patients and 1,570 Hb pairs). A Bland-Altman analysis and LOWESS curve showed that bias decreased with smaller Hb values in absolute numbers but increased relatively. The smoker status showed the greatest reduction in bias (0.1 g/dl, p<0.001) whereas BMI (0.07 g/dl, p = 0.0178), RBC transfusion (0.06 g/dl, p<0.001), statins (0.04 g/dl, p<0.05) and beta blocker (0.03 g/dl, p = 0.02) showed a slight effect on bias. Intraoperative substitution of volume and other co-medications did not influence the bias significantly. Conclusion: Many interventions like substitution of fluids, coagulating factors or RBC units rely on the accuracy of laboratory measurement devices. Although BGA Hb testing showed a consistently stable difference to CL, our data confirm that BGA devices are associated with different bias. Therefore, we suggest that hospitals assess their individual bias before implementing BGA as valid and stable supplement to CL. However, based on the finding that bias decreased with smaller Hb values, which in turn are used for transfusion decision, we expect no unnecessary or delayed RBC transfusion, and no major impact on the LIBERAL trial performance.