Diffusion tensor imaging (DTI) based assessment of white matter fiber tract integrity can support the diagnosis of Alzheimer’s disease (AD). The use of DTI as a biomarker, however, depends on its applicability in a multicenter setting accounting for effects of different MRI scanners. We applied multivariate machine learning (ML) to a large multicenter sample from the recently created framework of the European DTI study on Dementia (EDSD). We hypothesized that ML approaches may amend effects of multicenter acquisition. We included a sample of 137 patients with clinically probable AD (MMSE 20.6±5.3) and 143 healthy elderly controls, scanned in nine different scanners. For diagnostic classification we used the DTI indices fractional anisotropy (FA) and mean diffusivity (MD) and, for comparison, gray matter and white matter density maps from anatomical MRI. Data were classified using a Support Vector Machine (SVM) and a Naïve Bayes (NB) classifier. We used two cross-validation approaches, (i) test and training samples randomly drawn from the entire data set (pooled cross-validation) and (ii) data from each scanner as test set, and the data from the remaining scanners as training set (scanner-specific cross-validation). In the pooled cross-validation, SVM achieved an accuracy of 80% for FA and 83% for MD. Accuracies for NB were significantly lower, ranging between 68% and 75%. Removing variance components arising from scanners using principal component analysis did not significantly change the classification results for both classifiers. For the scanner-specific cross-validation, the classification accuracy was reduced for both SVM and NB. After mean correction, classification accuracy reached a level comparable to the results obtained from the pooled cross-validation. Our findings support the notion that machine learning classification allows robust classification of DTI data sets arising from multiple scanners, even if a new data set comes from a scanner that was not part of the training sample.
The identification of pathological atrophy in MRI scans requires specialized training, which is scarce outside dedicated centers. We sought to investigate the clinical usefulness of computer-generated representations of local grey matter (GM) loss or increased volume of cerebral fluids (CSF) as normalized deviations (z-scores) from healthy aging to either aid human visual readings or directly detect pathological atrophy.
Two experienced neuroradiologists rated atrophy in 30 patients with Alzheimer's disease (AD), 30 patients with frontotemporal dementia (FTD), 30 with dementia due to Lewy-body disease (LBD) and 30 healthy controls (HC) on a three-point scale in 10 anatomical regions as reference gold standard. Seven raters, varying in their experience with MRI diagnostics rated all cases on the same scale once with and once without computer-generated volume deviation maps that were overlaid on anatomical slices. In addition, we investigated the predictive value of the computer generated deviation maps on their own for the detection of atrophy as identified by the gold standard raters.
Inter and intra-rater agreements of the two gold standard raters were substantial (Cohen's kappa κ > 0.62). The intra-rater agreement of the other raters ranged from fair (κ = 0.37) to substantial (κ = 0.72) and improved on average by 0.13 (0.57 < κ < 0.87) when volume deviation maps were displayed. The seven other raters showed good agreement with the gold standard in regions including the hippocampus but agreement was substantially lower in e.g. the parietal cortex and did not improve with the display of atrophy scores. Rating speed increased over the course of the study and irrespective of the presentation of voxel-wise deviations.
Automatically detected large deviations of local volume were consistently associated with gold standard atrophy reading as shown by an area under the receiver operator characteristic of up to 0.95 for the hippocampus region. When applying these test characteristics to prevalences typically found in a memory clinic, we observed a positive or negative predictive value close to or above 0.9 in the hippocampus for almost all of the expected cases. The volume deviation maps derived from CSF volume increase were generally better in detecting atrophy.
Our study demonstrates an agreement of visual ratings among non-experts not further increased by displaying, region-specific deviations of volume. The high predictive value of computer generated local deviations independent from human interaction and the consistent advantages of CSF-over GM-based estimations should be considered in the development of diagnostic tools and indicate clinical utility well beyond aiding visual assessments.