Refine
Document Type
- Article (14)
Language
- English (14)
Has Fulltext
- yes (14)
Is part of the Bibliography
- no (14)
Keywords
- Computed tomography (3)
- CT (2)
- Magnetic resonance imaging (2)
- Anemia (1)
- Angiography (1)
- Anterior cruciate ligament (1)
- Artificial intelligence (1)
- Blood (1)
- Bone density (1)
- Bone disease (1)
Institute
- Medizin (14) (remove)
Purpose: To assess the diagnostic precision of three different workstations for measuring thoracic aortic aneurysms (TAAs) in vivo and ex vivo using either pre-interventional computed tomography angiography scans (CTA) or a specifically designed phantom model.
Methods: This retrospective study included 23 patients with confirmed TAA on routinely performed CTAs. In addition to phantom tube diameters, one experienced blinded radiologist evaluated the dimensions of TAAs on three different workstations in two separate rounds. Precision was assessed by calculating measurement errors. In addition, correlation analysis was performed using Pearson correlation.
Results: Measurements acquired at the Siemens workstation deviated by 3.54% (range, 2.78–4.03%; p = 0.14) from the true size, those at General Electric by 4.05% (range, 1.46–7.09%; p < 0.0001), and at TeraRecon by 4.86% (range, 3.22–6.45%; p < 0.0001). Accordingly, Siemens provided the most precise workstation at simultaneously most fluctuating values (scattering of 4.46%). TeraRecon had the smallest fluctuation (scattering of 2.83%), but the largest deviation from the true size of the phantom. The workstation from General Electric showed a scattering of 2.94%. The highest overall correlation between the 1st and 2nd rounds was observed with measurements from Siemens (r = 0.898), followed by TeraRecon (r = 0.799), and General Electric (r = 0.703). Repetition of measurements reduced processing times by 40% when using General Electric, by 20% with Siemens, and by 18% with TeraRecon.
Conclusions: In conclusion, all three workstations facilitated precise assessment of dimensions in the majority of cases at simultaneously high reproducibility, ensuring accurate pre-interventional planning of thoracic endovascular aortic repair.
Distinct immune patterns of hepatocellular carcinoma (HCC) may have prognostic implications in the response to transarterial chemoembolization (TACE). Thus, we aimed to exploratively analyze tumor tissue of HCC patients who do or do not respond to TACE, and to identify novel prognostic biomarkers predictive of response to TACE. We retrospectively included 15 HCC patients who had three consecutive TACE between January 2019 and November 2019. Eight patients had a response while seven patients had no response to TACE. All patients had measurable disease according to mRECIST. Corresponding tumor tissue samples were processed for differential expression profiling using NanoString nCounter® PanCancer immune profiling panel. Immune-related pathways were broadly upregulated in TACE responders. The top differentially regulated genes were the upregulated CXCL1 (log2fc 4.98, Benjamini–Hochberg (BH)-p < 0.001), CXCL6 (log2fc 4.43, BH-p = 0.016) and the downregulated MME (log2fc −4.33, BH-p 0.001). CD8/T-regs was highly increased in responders, whereas the relative number of T-regs to tumor-infiltrating lymphocytes (TIL) was highly decreased. We preliminary identified CXCL1 and CXCL6 as candidate genes that might have the potential to serve as therapeutically relevant biomarkers in HCC patients. This might pave the way to improve patient selection for TACE in HCC patients beyond expert consensus.
Highlights
• Early reconstruction of injured cruciate ligaments improves functional outcomes.
• Modern CT imaging can be used to rapidly identify patients with injury to the cruciate ligaments and streamline therapeutic pathways.
• Dual-energy CT demonstrates superior diagnostic accuracy compared to single-energy CT.
Abstract
Background: This study aimed to evaluate the clinical utility of modern single and dual-energy computed tomography (CT) for assessing the integrity of the cruciate ligaments in patients that sustained acute trauma.
Methods: Patients who underwent single- or dual-energy CT followed by 3 Tesla magnetic resonance imaging (MRI) or knee joint arthroscopy between 01/2016 and 12/2022 were included in this retrospective, monocentric study. Three radiologists specialized in musculoskeletal imaging independently evaluated all CT images for the presence of injury to the cruciate ligaments. An MRI consensus reading of two experienced readers and arthroscopy provided the reference standard. Diagnostic accuracy parameters and area under the receiver operator characteristic curve (AUC) were the primary metrics for diagnostic performance.
Results: CT images of 204 patients (median age, 49 years; IQR 36 – 64; 113 males) were evaluated. Dual-energy CT yielded significantly higher diagnostic accuracy and AUC for the detection of injury to the anterior (94% [240/255] vs 75% [266/357] and 0.89 vs 0.66) and posterior cruciate ligaments (95% [243/255] vs 87% [311/357] and 0.90 vs 0.61) compared to single-energy CT (all parameters, p <.005). Diagnostic confidence and image quality were significantly higher in dual-energy CT compared to single-energy CT (all parameters, p <.005).
Conclusions: Modern dual-energy CT is readily available and can serve as a screening tool for detecting or excluding cruciate ligament injuries in patients with acute trauma. Accurate diagnosis of cruciate ligament injuries is crucial to prevent adverse outcomes, including delayed treatment, chronic instability, or long-term functional limitations.
Purpose: To stratify differences in visual semantic and quantitative imaging features in intensive care patients with nonspecific mastoid effusions versus patients with acute mastoiditis (AM) requiring surgical treatment. Methods: We included 48 patients (male, 28; female, 20; mean age, 59.5 ± 18.1 years) with mastoid opacification (AM, n = 24; control, n = 24) who underwent clinically indicated cerebral CT between 12/2007 and 07/2018 in this retrospective study. Semantic features described the extend and asymmetry of mastoid and middle-ear cavity opacification and complications like erosive changes. Minimum, maximum and mean Hounsfield unit (HU) values were obtained as quantitative features. We analyzed the features employing univariate testing. Results: Compared to intensive care patients, AM patients revealed asymmetric mastoid or middle-ear cavity opacification (likelihood-ratio (LR) < 0.001). Applying a dedicated threshold of the extent of opacification, AM patients reached significance levels of LR = 0.042 and 0.002 for mastoid and middle-ear cavity opacification. AM cases showed higher maximum and mean HU values (p = 0.009, p = 0.024). Conclusions: We revealed that the extent and asymmetry of mastoid and middle-ear cavity opacification differs significantly between AM patients and intensive care patients. Multicenter research is needed to expand our cohort and possibly pave the way to build a non-invasive predictive model for AM in the future.
Background: Dual-energy CT (DECT)-derived bone mineral density (BMD) of the distal radius and other CT-derived metrics related to bone health have been suggested for opportunistic osteoporosis screening and risk evaluation for sustaining distal radius fractures (DRFs).
Methods: The distal radius of patients who underwent DECT between 01/2016 and 08/2021 was retrospectively analyzed. Cortical Hounsfield Unit (HU), trabecular HU, cortical thickness, and DECT-based BMD were acquired from a non-fractured, metaphyseal area in all examinations. Receiver-operating characteristic (ROC) analysis was conducted to determine the area under the curve (AUC) values for predicting DRFs based on DECT-derived BMD, HU values, and cortical thickness. Logistic regression models were then employed to assess the associations of these parameters with the occurrence of DRFs.
Results: In this study, 263 patients (median age: 52 years; interquartile range: 36–64; 132 women; 192 fractures) were included. ROC curve analysis revealed a higher area under the curve (AUC) value for DECT-derived BMD compared to cortical HU, trabecular HU, and cortical thickness (0.91 vs. 0.61, 0.64, and 0.69, respectively; p <.001). Logistic regression models confirmed the association between lower DECT-derived BMD and the occurrence of DRFs (Odds Ratio, 0.83; p <.001); however, no influence was observed for cortical HU, trabecular HU, or cortical thickness.
Conclusions: DECT can be used to assess the BMD of the distal radius without dedicated equipment such as calibration phantoms to increase the detection rates of osteoporosis and stratify the individual risk to sustain DRFs. In contrast, assessing HU-based values and cortical thickness does not provide clinical benefit.
Rationale and objectives: To provide a detailed analysis of injury patterns of the spine following blunt trauma and establish the role of supplementary MRI by evaluating discrepancies in the detection rates of damaged structures in CT and MRI.
Method: 216 patients with blunt trauma to the spine who underwent CT followed by supplementary MRI were included in this study. Two board-certified radiologists blinded to clinical symptoms and injury mechanisms independently interpreted all acquired CT and MRI images. The interpretation was performed using a dedicated catalogue of typical findings associated with spinal trauma and assessed for spinal stability using the AO classification systems.
Results: Lesions to structures associated with spinal instability were present in 31.0% in the cervical spine, 12.3% in the thoracic spine, and 29.9% in the lumbar spine. In all spinal segments, MRI provided additional information regarding potentially unstable injuries. Novel information derived from supplementary MRI changed clinical management in 3.6% of patients with injury to the cervical spine. No change in clinical management resulted from novel information on the thoracolumbar spine. Patients with injuries to the vertebral body, intervertebral disc, or spinous process were significantly more likely to benefit from supplementary MRI.
Conclusion: In patients that sustained blunt spinal trauma, supplementary MRI of the cervical spine should routinely be performed to detect injuries that require surgical treatment, whereas CT is the superior imaging modality for the detection of unstable injuries in the thoracolumbar spine.
Highlights
• Assessment of coronary artery plaque burden according to the CAC-DRS Score correlated well with pulmonary involvement of SARS-CoV-2 pneumonia (min. r=0.81, 95% CI 0.76 to 0.86).
• Visual and quantitative CAC-DRS Score of coronary artery plaque burden provided independent prognostic information on all-cause mortality in patients with SARS-CoV-2 pneumonia (p=0.0016 and p<0.0001, respectively).
• Incorporating CAC-DRS Score and pulmonary involvement into clinical decision making revealed great potential to discriminate patients with fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89 to 0.97) and the need for intensive care treatment (AUC 0.801, 95% CI 0.77 to 0.83).
Purpose: To assess and correlate pulmonary involvement and outcome of SARS-CoV-2 pneumonia with the degree of coronary plaque burden based on the CAC-DRS classification (Coronary Artery Calcium Data and Reporting System).
Methods: This retrospective study included 142 patients with confirmed SARS-CoV-2 pneumonia (58 ± 16 years; 57 women) who underwent non-contrast CT between January 2020 and August 2021 and were followed up for 129 ± 72 days. One experienced blinded radiologist analyzed CT series for the presence and extent of calcified plaque burden according to the visual and quantitative HU-based CAC-DRS Score. Pulmonary involvement was automatically evaluated with a dedicated software prototype by another two experienced radiologists and expressed as Opacity Score.
Results: CAC-DRS Scores derived from visual and quantitative image evaluation correlated well with the Opacity Score (r=0.81, 95% CI 0.76-0.86, and r=0.83, 95% CI 0.77-0.89, respectively; p<0.0001) with higher correlation in severe than in mild stage SARS-CoV-2 pneumonia (p<0.0001). Combined, CAC-DRS and Opacity Scores revealed great potential to discriminate fatal outcomes from a mild course of disease (AUC 0.938, 95% CI 0.89-0.97), and the need for intensive care treatment (AUC 0.801, 95% CI 0.77-0.83). Visual and quantitative CAC-DRS Scores provided independent prognostic information on all-cause mortality (p=0.0016 and p<0.0001, respectively), both in univariate and multivariate analysis.
Conclusions: Coronary plaque burden is strongly correlated to pulmonary involvement, adverse outcome, and death due to respiratory failure in patients with SARS-CoV-2 pneumonia, offering great potential to identify individuals at high risk.
Rationale and Objectives: Lumbar disk degeneration is a common condition contributing significantly to back pain. The objective of the study was to evaluate the potential of dual-energy CT (DECT)-derived collagen maps for the assessment of lumbar disk degeneration.
Patients and Methods: We conducted a retrospective analysis of 127 patients who underwent dual-source DECT and MRI of the lumbar spine between 07/2019 and 10/2022. The level of lumbar disk degeneration was categorized by three radiologists as follows: no/mild (Pfirrmann 1&2), moderate (Pfirrmann 3&4), and severe (Pfirrmann 5). Recall (sensitivity) and accuracy of DECT collagen maps were calculated. Intraclass correlation coefficient (ICC) was used to evaluate inter-reader reliability. Subjective evaluations were performed using 5-point Likert scales for diagnostic confidence and image quality.
Results: We evaluated a total of 762 intervertebral disks from 127 patients (median age, 69.7 (range, 23.0–93.7), female, 56). MRI identified 230 non/mildly degenerated disks (30.2%), 484 moderately degenerated disks (63.5%), and 48 severely degenerated disks (6.3%). DECT collagen maps yielded an overall accuracy of 85.5% (1955/2286). Recall (sensitivity) was 79.3% (547/690) for the detection of no/mild lumbar disk degeneration, 88.7% (1288/1452) for the detection of moderate disk degeneration, and 83.3% (120/144) for the detection of severe disk degeneration (ICC = 0.9). Subjective evaluations of DECT collagen maps showed high diagnostic confidence (median 4) and good image quality (median 4).
Conclusion: The use of DECT collagen maps to distinguish different stages of lumbar disk degeneration may have clinical significance in the early diagnosis of disk-related pathologies in patients with contraindications for MRI or in cases of unavailability of MRI.
Background: To assess the potential of radiomic features to quantify components of blood in intraaortic vessels to non-invasively predict moderate-to-severe anemia in non-contrast enhanced CT scans. Methods: One hundred patients (median age, 69 years; range, 19–94 years) who received CT scans of the thoracolumbar spine and blood-testing for hemoglobin and hematocrit levels ± 24 h between 08/2018 and 11/2019 were retrospectively included. Intraaortic blood was segmented using a spherical volume of interest of 1 cm diameter with consecutive radiomic analysis applying PyRadiomics software. Feature selection was performed applying analysis of correlation and collinearity. The final feature set was obtained to differentiate moderate-to-severe anemia. Random forest machine learning was applied and predictive performance was assessed. A decision-tree was obtained to propose a cut-off value of CT Hounsfield units (HU). Results: High correlation with hemoglobin and hematocrit levels was shown for first-order radiomic features (p < 0.001 to p = 0.032). The top 3 features showed high correlation to hemoglobin values (p) and minimal collinearity (r) to the top ranked feature Median (p < 0.001), Energy (p = 0.002, r = 0.387), Minimum (p = 0.032, r = 0.437). Median (p < 0.001) and Minimum (p = 0.003) differed in moderate-to-severe anemia compared to non-anemic state. Median yielded superiority to the combination of Median and Minimum (p(AUC) = 0.015, p(precision) = 0.017, p(accuracy) = 0.612) in the predictive performance employing random forest analysis. A Median HU value ≤ 36.5 indicated moderate-to-severe anemia (accuracy = 0.90, precision = 0.80). Conclusions: First-order radiomic features correlate with hemoglobin levels and may be feasible for the prediction of moderate-to-severe anemia. High dimensional radiomic features did not aid augmenting the data in our exemplary use case of intraluminal blood component assessment.
Purpose: To identify transjugular intrahepatic portosystemic shunt (TIPS) thrombosis in abdominal CT scans applying quantitative image analysis.
Materials and methods: We retrospectively screened 184 patients to include 20 patients (male, 8; female, 12; mean age, 60.7 ± 8.87 years) with (case, n = 10) and without (control, n = 10) in-TIPS thrombosis who underwent clinically indicated contrast-enhanced and unenhanced abdominal CT followed by conventional TIPS-angiography between 08/2014 and 06/2020. First, images were scored visually. Second, region of interest (ROI) based quantitative measurements of CT attenuation were performed in the inferior vena cava (IVC), portal vein and in four TIPS locations. Minimum, maximum and average Hounsfield unit (HU) values were used as absolute and relative quantitative features. We analyzed the features with univariate testing.
Results: Subjective scores identified in-TIPS thrombosis in contrast-enhanced scans with an accuracy of 0.667 – 0.833. Patients with in-TIPS thrombosis had significantly lower average (p < 0.001), minimum (p < 0.001) and maximum HU (p = 0.043) in contrast-enhanced images. The in-TIPS / IVC ratio in contrast-enhanced images was significantly lower in patients with in-TIPS thrombosis (p < 0.001). No significant differences were found for unenhanced images. Analyzing the visually most suspicious ROI with consecutive calculation of its ratio to the IVC, all patients with a ratio < 1 suffered from in-TIPS thrombosis (p < 0.001, sensitivity and specificity = 100%).
Conclusion: Quantitative analysis of abdominal CT scans facilitates the stratification of in-TIPS thrombosis. In contrast-enhanced scans, an in-TIPS / IVC ratio < 1 could non-invasively stratify all patients with in-TIPS thrombosis.