Refine
Year of publication
- 2006 (46) (remove)
Document Type
- Preprint (23)
- Article (11)
- Doctoral Thesis (8)
- Conference Proceeding (1)
- Diploma Thesis (1)
- diplomthesis (1)
- Working Paper (1)
Language
- English (46) (remove)
Has Fulltext
- yes (46) (remove)
Is part of the Bibliography
- no (46) (remove)
Keywords
- Photon (2)
- RHIC (2)
- Zeitprojektionskammer (2)
- ADD (1)
- Binary encounter approximation (1)
- Coupled-channel self-consistent calculation (1)
- D-Dbar (1)
- D-meson spectral density (1)
- Dotierter Halbleiter (1)
- Ferromagnetische Spinkette (1)
Institute
- Physik (46) (remove)
We study forward-backward charge fluctuations to probe the correlations among produced particles in ultra relativistic heavy ion collisions. We develop a model that describes the forward-backward dynamical fluctuations and apply it to interpret the recent PHOBOS data. Within the present model, the dynamical fluctuations are related to the particle production mechanism via cluster decay and to long range correlations between the forward and backward rapidity hemispheres. We argue that with a tight centrality cut, PHOBOS may see a strong decrease of the dynamical fluctuations. Within the present model, this deterioration of the correlation among the produced hadrons can be interpreted as a sign for the production of a hot, dense and interacting medium.
A new experimental system has been set up with the ability to investigate catalytic processes and charge transfer of acrylonitrile on copper. For this purpose a new Time of Flight Mass Spectrometer to measure both the reaction outcome and electron energy distributions has been designed and tested. First experiments have been carried out, in which the width of the two-photon photoelectron energy distribution can be varied by changing the wavelength of the incident laser beam. This method allows high precision measurements of the work function and will be useful in the study with adsorbates, physi- or chemisorbed. In first adsorption measurements the excitation of vibrational modes of acrylonitrile has been seen to be consistent with earlier gas-phase experiments. Electron energy spectra taken with the electron analyzer with high resolution showed a clear defect in the electron yield at energies around the energy of one vibrational mode, indicating the possibility of resonant vibrational excitation by electron impact. More indications to that process were found i first electron spectra from the new TOF-MS, since a threshold for the capture probability is found at energies close to vibrational excitation. The threshold vanishes when the exposure is amplified significantly, indicating that electrons are scattered multiple and no resonance are be observed anymore. The experiments carried out were just the starting point in understanding the mechanism of the reaction. A new femtosecond laser system which is currently set up will give not only a time-resolved information on the reaction pathways but also give the possibility to create non-thermal electrons and to study intermediate states of the photoemission and the influence of the adsorbate on them. In addition the rotation of the electron analyzer will permit angle-resolved measurements of the scattering process of the electrons and the vibrational excitation via this pathway. With the new cooling system applied it will also be interesting to study the excitation process at lower temperatures. Below -160° C there are different geometries of the molecule predicted to be present at the surface. At these temperatures the thermal effects should play a major role, so that a thermal decoupling of the electrons is very desirable.
The D-meson spectral density at finite temperature is obtained within a self-consistent coupled-channel approach. For the bare meson–baryon interaction, a separable potential is taken, whose parameters are fixed by the position and width of the Λc(2593) resonance. The quasiparticle peak stays close to the free D-meson mass, indicating a small change in the effective mass for finite density and temperature. Furthermore, the spectral density develops a considerable width due to the coupled-channel structure. Our results indicate that the medium modifications for the D-mesons in nucleus-nucleus collisions at FAIR (GSI) will be dominantly on the width and not, as previously expected, on the mass.
We propose to use the hadron number fluctuations in the limited momentum regions to study the evolution of initial flows in high energy nuclear collisions. In this method by a proper preparation of a collision sample the projectile and target initial flows are marked in fluctuations in the number of colliding nucleons. We discuss three limiting cases of the evolution of flows, transparency, mixing and reflection, and present for them quantitative predictions obtained within several models. Finally, we apply the method to the NA49 results on fluctuations of the negatively charged hadron multiplicity in Pb+Pb interactions at 158A GeV and conclude that the data favor a hydrodynamical model with a significant degree of mixing of the initial flows at the early stage of collisions.
We study the gluonic phase in a two-flavor color superconductor as a function of the ratio of the gap over the chemical potential mismatch, Δ/δμ. We find that the gluonic phase resolves the chromomagnetic instability encountered in a two-flavor color superconductor for Δ/δμ<2. We also calculate approximately the free energies of the gluonic phase and the single plane-wave LOFF phase and show that the former is favored over the latter for a wide range of coupling strengths.
The outer segment of vertebrate photoreceptors is a specialized compartment that hosts all the signaling components required for visual transduction. Specific to rod photoreceptors is an unusual set of three glutamic acid-rich proteins (GARPs) as follows: two soluble forms, GARP1 and GARP2, and the N-terminal cytoplasmic domain (GARP′ part) of the B1 subunit of the cyclic GMP-gated channel. GARPs have been shown to interact with proteins at the rim of the disc membrane. Here we characterized native GARP1 and GARP2 purified from bovine rod photoreceptors. Amino acid sequence analysis of GARPs revealed structural features typical of “natively unfolded” proteins. By using biophysical techniques, including size-exclusion chromatography, dynamic light scattering, NMR spectroscopy, and circular dichroism, we showed that GARPs indeed exhibit a large degree of intrinsic disorder. Analytical ultracentrifugation and chemical cross-linking showed that GARPs exist in a monomer/multimer equilibrium. The results suggested that the function of GARP proteins is linked to their structural disorder. They may provide flexible spacers or linkers tethering the cyclic GMP-gated channel in the plasma membrane to peripherin at the disc rim to produce a stack of rings of these protein complexes along the long axis of the outer segment. GARP proteins could then provide the environment needed for protein interactions in the rim region of discs.
The QCD equation of state is not often discussed in cosmology. However, the relic density of
weakly interacting massive particles (WIMPs) depends on the entropy and the expansion rate of
the Universe when they freeze out, at a temperature in the range 400 MeV – 40GeV, where QCD
corrections are still important. We use recent analytic and lattice calculations of the QCD pressure
to produce a new equation of state suitable for use in relic density calculations. As an example,
we show that relic densities calculated by the dark matter package DarkSUSY receive corrections
of several per cent, within the observational accuracy of the Planck CMB mission, due for launch
in 2007.
In the present work we applied the Optically read out PArticle track Chamber, OPAC, for the measurement of radial dose distributions, d(r), around tracks of heavy ions passing through the gas-filled sensitive volume of the chamber. The measured data were compared with d(r) functions derived from data calculated with the Monte Carlo particle transport code, TRAX – which is used for the heavy ion therapy planning at GSI. To measure this quantity we have used here an optically read out time projection chamber (OPAC) with a parallel-drift field and one or several electron and light amplification stages. The two dimensional projection of the three dimensional ionization pattern caused by the ionizing particle passing through the chamber is captured by an image intensified CCD camera. The work is motivated by the role the radial dose distribution plays in the estimation of the relative biological effectiveness (RBE) of heavy ions, e.g. in radiation therapy and in radiation protection. The most successful model for high-dose irradiation with ions (applicable e.g. for heavy ion therapy) is found to be the local effect model (LEM). The present work intends to deliver measured data for one of the basic physical parameters which serve as input for the application of the local effect model: the radial dose distribution, d(r). The first goal of our measurement program was the measurement of d(r) distributions around carbon ions of different energies from 400 MeV/u down to the Bragg peak regions. We found an excellent agreement between the measured and simulated distributions at all carbon energies for the r–range in which the measurements deliver useful results. The lower limit of this range is about 100 nm and the upper limit is 6000 nm at a resolution of down to 33 nm - if scaled to water density. Despite the simplifications in the TRAX code (e.g. binary encounter theory for the emission ionization electrons), the discrepancies between the simulated and measured d(r) distributions are found to be lower than the measurement uncertainties at most measured carbon ion energies in almost the whole observed r-range. Hence, within the limitations of our measurements we can conclude that the precision of TRAX is sufficient to simulate the d(r) distributions around carbon ions to serve as input parameter for therapy planning. However, this conclusion is only valid for larger radial distances (r >100 nm). For smaller radial distances the measured data are dominated by the diffusion. Apart from carbon ion tracks, tracks of very heavy ions (40Ar, 84Kr and 238U) were also measured with OPAC. The simulated d(r) values were typically slightly or significantly higher than the measured data in the 100 nm < r < 5000 nm region. The experience has shown: the heavier or the faster the ion, the higher the discrepancies. On the one hand, we found a surprisingly good agreement between measurements and simulations if the ions had energies of around 50 MeV/u (i.e. relatively low energy). On the other hand, at higher energies, simulated data underestimate the measured ones by up to a factor of two in the region of 100 nm < r < 1000 nm for 84Kr (E = 650 MeV/u) or in the region of 100 nm < r < 6000 nm for 238U (E = 1 GeV/u). A possible reason for these discrepancies is that the BEA model, used in TRAX for the production ionization electrons, is not adequate for very heavy projectiles. The energy values of the very heavy ions were selected with the aim of comparing the track structures - and namely the d(r) distributions - of ions with largely different atomic mass but similar LET values. From the Z-dependency of the stopping power we know that for heavier ions a higher specific ion energy (expressed in MeV/u) is required to provide the same LET. For example the common LET of 315 keV/micro-m was achieved at largely different specific energy levels of 4,4 MeV/u for 12C, 65 MeV/u for 40Ar and 650 MeV/u for 84Kr ions. The difference in the track structures was expected mainly due to the different ion velocities and thus e.g. different ranges of d-electrons. This expectation could be confirmed by the measurements. The reason why - in line with the simulations - no strong differences could be observed in the d(r) distributions of the argon and krypton ions is the relatively small difference in the velocities of the both ion types in conjunction with the limited range in r, where the data can be compared. In contrary, the d(r) function of the carbon ion shows a qualitatively different behavior than the heavier ions inside the observable radius-range - in agreement with the simulations.
The freeze out of the expanding systems, created in relativistic heavy ion collisions, is discussed. We combine kinetic freeze out equations with Bjorken type system expansion into a unified model. The important feature of the proposed scenario is that physical freeze out is completely finished in a finite time, which can be varied from 0 (freeze out hypersurface) to infinit. The dependence of the post freeze out distribution function on the freeze out time will be studied. Model allows analytical analyses for the simplest systems such as pion gas. We shall see that the basic freeze out features, pointed out in the earlier works, are not smeared out by the expansion of the system. The entropy evolution in such a scenario is also studied.
A new technique for precision ion implantation has been developed. A scanning probe has been equipped with a small aperture and incorporated into an ion beamline, so that ions can be implanted through the aperture into a sample. By using a scanning probe the target can be imaged in a non-destructive way prior to implantation and the probe together with the aperture can be placed at the desired location with nanometer precision. In this work first results of a scanning probe integrated into an ion beamline are presented. A placement resolution of about 120 nm is reported. The final placement accuracy is determined by the size of the aperture hole and by the straggle of the implanted ion inside the target material. The limits of this technology are expected to be set by the latter, which is of the order of 10 nm for low energy ions. This research has been carried out in the context of a larger program concerned with the development of quantum computer test structures. For that the placement accuracy needs to be increased and a detector for single ion detection has to be integrated into the setup. Both issues are discussed in this thesis. To achieve single ion detection highly charged ions are used for the implantation, as in addition to their kinetic energy they also deposit their potential energy in the target material, therefore making detection easier. A special ion source for producing these highly charged ions was used and their creation and interactions with solids of are discussed in detail.