Keywords
- Aortic valve replacement (2)
- LVAD (2)
- Aortic Valve Replacement (1)
- Aortic valve (1)
- Apoptosis (1)
- Biological heart valves (1)
- Bioprosthesis (1)
- Cardiac surgery (1)
- Cell metabolism (1)
- Daptomycin (1)
Institute
- Medizin (17)
Minimal invazif endoskopik giriflimlerin kalp cerrahisinde kullanımı ancak telemanipülatör sistemlerin kullanıma girmesiyle mümkün olmufltur. Bu çalıflmada total endoskopik revaskülarizasyon için kullanılan robotik destekli telemanipülasyon sistemleri gözden geçirilip, çalıflan ve duran kalpte uygulamalar derlenmifltir. Robotik cerrahi günümüzde halen geliflme aflamasındadır. Maliyetin yüksek oluflu ve sadece seçilmifl bir hasta grubunda uygulanabiliyor olması bu yeni tekni¤in en büyük sınırlayıcı faktörleridir. Ancak teknoloji üzerine çalıflmalar ve özellikle anastomoz tekniklerinin geliflmesiyle koroner revaskülarizasyon için bir alternatif olacaktır. Henüz istenen hedeflere ulaflılmamıflsa da gelecek umut vericidir.
The radial artery as a conduit for coronary artery bypass grafting : review of current knowledge
(2006)
The effect of coronary artery bypass grafting (CABG) lasts as long as the grafts are patent. The internal mammary artery has been considered the "golden" graft due to the superb long-term patency, exceeding 90% at 10 years. The saphenous vein grafts, unfortunately, tend to occlude with a rate of 10-15% within a year after surgery, and eventually, at 10 years after the operation, as much as 60-70% of these vein grafts are either occluded or have angiographic evidence of atherosclerosis. The search for another "arterial conduit", the radial artery, has intensified through the last 15 years in hope to provide a better graft than the saphenous vein for CABG. This article reviews the current knowledge for the radial artery as a conduit in CABG. (Anadolu Kardiyol Derg 2006; 6: 153-62)
Background The arterial in line application of the leukocyte inhibition module (LIM) in the cardiopulmonary bypass (CPB) limits overshooting leukocyte activity during cardiac surgery. We now studied in a porcine model whether LIM may have beneficial effects on cardiac function after CPB. Methods German landrace pigs underwent CPB (60 min myocardial ischemia; 30 min reperfusion)without (group I; n=6) or with LIM (group II; n=6). The cardiac indices (CI) and cardiac function were analyzed pre and post CPB with a Swan-Ganz catheter and the cardiac function analyzer. Neutrophil labeling with technetium, scintigraphy, and histological analyses were done to track activated neutrophils within the organs. Results LIM prevented CPB-associated increase of neutrophil counts in peripheral blood. In group I, the CI significantly declined post CPB (post: 3.26 +/- 0.31; pre: 4.05 +/- 0.45 l/min/m2; p<0.01). In group II, the CI was only slightly reduced (post: 3.86 +/- 0.49; pre 4.21 +/- 1.32 l/min/m2; p=0.23). Post CPB, the intergroup difference showed significantly higher CI values in the LIM group (p<0.05) which was in conjunction with higher pre-load independent endsystolic pressure volume relationship (ESPVR) values (group I: 1.57 +/- 0.18; group II: 1.93 +/- 0.16; p<0.001). Moreover, the systemic vascular resistance and pulmonary vascular resistance were lower in the LIM group. LIM appeared to accelerate the sequestration of hyperactivated neutrophils in the spleen and to reduce neutrophil infiltration of heart and lung. Conclusions Our data provide strong evidence that LIM improves perioperative hemodynamics and cardiac function after CPB by limiting neutrophil activity and inducing accelerated sequestration of neutrophils in the spleen.
Biventricular pacing has been suggested in end-stage heart failure. We present a 59-year-old patient undergoing second re-do CABG (coronary artery bypass graft) and carotid artery endarterectomy. Ejection fraction was 15%, QRS-width 175 ms. Following the carotid and CABG procedure, an implanted single-chamber ICD (implantable cardioverter defibrillator) was upgraded to permanent biventricular DDD pacing by implantation of one epicardial left ventricular and one epicardial atrial electrode. At follow-up two months postoperatively ejection fraction had significantly improved to 45%, the patient underwent stress test with adequate load and reported a good quality of life.
Background: We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups.
Methods: One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20) or mechanical prosthesis (MP, Edwards Mira n = 20) in group 1 (age < 55 years), either stentless bioprosthesis (CE Prima Plus n = 20) or MP (Edwards Mira n = 20) in group 2 (age 55-75 years) and either stentless (CE Prima Plus n = 20) or stented bioprosthesis (CE Perimount n = 20) in group 3 (age > 75). Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year.
Results: In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005) with comparable left ventricular mass regression (LVMR). Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81). The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06). Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group.
Conclusions: Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs.
Vacuum-assisted closure (VAC) of complex infected wounds has recently gained popularity among various surgical specialties. The system is based on the application of negative pressure by controlled suction to the wound surface. The effectiveness of the VAC System on microcirculation and the promotion of granulation tissue proliferation are proved. In our case report we illustrate a scenario were a patient developed severe bleeding from the ascending aorta by penetration of wire fragments in the vessel. We conclude that all free particles in the sternum have to be removed completely before negative pressure is used.
Vasoplegia is a severe complication after cardiac surgery. Within the last years the administration of nitric oxide synthase inhibitor methylene blue (MB) became a new therapeutic strategy. Our aim was to investigate the role of MB on transendothelial migration of circulating blood cells, the potential role of cyclic cGMP, eNOS and iNOS in this process, and the influence of MB on endothelial cell apoptosis. Human vascular endothelial cells (HuMEC-1) were treated for 30 minutes or 2 hours with different concentrations of MB. Inflammation was mimicked by LPS stimulation prior and after MB. Transmigration of PBMCs and T-Lymphocytes through the treated endothelial cells was investigated. The influence of MB upon the different subsets of PBMCs (Granulocytes, T- and B-Lymphocytes, and Monocytes) was assessed after transmigration by means of flow-cytometry. The effect of MB on cell apoptosis was evaluated using Annexin-V and Propidium Iodide stainings. Analyses of the expression of cyclic cGMP, eNOS and iNOS were performed by means of RT-PCR and Western Blot. Results were analyzed using unpaired Students T-test. Analysis of endothelial cell apoptosis by MB indicated a dose-dependent increase of apoptotic cells. We observed time- and dose-dependent effects of MB on transendothelial migration of PBMCs. The prophylactic administration of MB led to an increase of transendothelial migration of PBMCs but not Jurkat cells. Furthermore, HuMEC-1 secretion of cGMP correlated with iNOS expression after MB administration but not with eNOS expression. Expression of these molecules was reduced after MB administration at protein level. This study clearly reveals that endothelial response to MB is dose- and especially time-dependent. MB shows different effects on circulating blood cell-subtypes, and modifies the release patterns of eNOS, iNOS, and cGMP. The transendothelial migration is modulated after treatment with MB. Furthermore, MB provokes apoptosis of endothelial cells in a dose/time-dependent manner.
Background: The introduction of fast-track treatment procedures following cardiac surgery has significantly shortened hospitalisation times in intensive care units (ICU). Readmission to intensive care units is generally considered a negative quality criterion. The aim of this retrospective study is to statistically analyse risk factors and predictors for re-admission to the ICU after a fast-track patient management program.
Methods: 229 operated patients (67 ± 11 years, 75% male, BMI 27 ± 3, 6/2010-5/2011) with use of extracorporeal circulation (70 ± 31 min aortic crossclamping, CABG 62%) were selected for a preoperative fast-track procedure (transfer on the day of surgery to an intermediate care (IMC) unit, stable circulatory conditions, extubated). A uni- and multivariate analysis were performed to identify independent predictors for re-admission to the ICU.
Results: Over the 11-month study period, 36% of all preoperatively declared fast-track patients could not be transferred to an IMC unit on the day of surgery (n = 77) or had to be readmitted to the ICU after the first postoperative day (n = 4). Readmission or ICU stay signifies a dramatic worsening of the patient outcome (mortality 0/10%, mean hospital stay 10.3 ± 2.5/16.5 ± 16.3, mean transfusion rate 1.4 ± 1,7/5.3 ± 9.1). Predicators for failure of the fast-track procedure are a preoperative ASA class > 3, NYHA class > III and an operation time >267 min ± 74. The significant risk factors for a major postoperative event (= low cardiac output and/or mortality and/or renal failure and/or re-thoracotomy and/or septic shock and/or wound healing disturbances and/or stroke) are a poor EF (OR 2.7 CI 95% 0.98-7.6) and the described ICU readmission (OR 0.14 CI95% 0.05-0.36).
Conclusion: Re-admission to the ICU or failure to transfer patients to the IMC is associated with a high loss of patient outcome. The ASA > 3, NYHA class > 3 and operation time >267 minutes are independent predictors of fast track protocol failure.
A 48 year old patient with dilated cardiomyopathy and chronic acne inversa underwent implantation of a LVAD system (Heartmate II, Thoratec, USA) March 2011. During 2011 and 2012 the patient was repeatedly readmitted for treatment of driveline infection with MRSA. Colonization was controlled with Linezolid and Rifampicin however reoccurred after discontinuation. In August 2012 the LVAD-system was exchanged due to pump dysfunction (HVAD, HeartWare Inc., USA). Postoperatively, the patient presented with ascites which secreted through the driveline exit. Consequently, the abdominal wall was surgically corrected to prevent exit of peritoneal fluid through the driveline, and the patient was discharged with sterile wound swabs. However 6 weeks after discharge the driveline exit wound started secreting pus showing abundant growth of multi resistant staphylococcus aureus (MRSA). With clinical signs of increasing liver failure with regular need for paracentesis, and clinical signs of local infection, a CT scan of the abdomen was performed revealing an enrichment of contrast medium along the driveline and an abscess-like formation on the abdominal wall. Patient was admitted receiving regular dose Daptomycin and Rifampicin. The latter was discontinued after ten days. The abscess, surrounding driveline exit and abdominal wall cavity was excised and vacuum treatment initiated. Total duration of Daptomycin therapy was 3 weeks. While first week skin and wound swabs were still positive for MRSA, all samples were sterile after the second week. Inflammation was monitored by leucocyte count and IL6. The secretion of pus along the driveline ceased, the wound cavity was closed subsequently. After discharge and stop of antibiotics skin and driveline swabs remained negative for MRSA (10 weeks).
OBJECTIVES: Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre.
METHODS: All consecutive patients undergoing isolated aortic valve replacement with either a Carpentier-Edwards Magna pericardial prosthesis or a Medtronic Mosaic porcine prosthesis between 2002 and 2008 were analysed regarding preoperative characteristics, short- and long-term survival, valve-related complications and echocardiographic findings.
RESULTS: The Medtronic Mosaic was implanted in 163 patients and the Carpentier-Edwards Magna in 295 patients. The sizes of implanted valves were 22.4 ± 1.5 mm for the Mosaic and 21.8 ± 1.8 mm for the Magna (P = 0.001). The long-term survival rate was 76 and 56% after 5 and 10 years for the Medtronic Mosaic, which was comparable with the Carpentier-Edwards Magna (77 and 57%; P = 0.92). Overall long-term survival was comparable with an age- and sex-matched Austrian general population for both groups. Valve-related adverse events were similar between groups. The postoperative mean transvalvular gradient was significantly increased in the Mosaic group (24 ± 9 mmHg vs 17 ± 7 mmHg; P < 0.001).
CONCLUSIONS: Both types of aortic bioprostheses offer excellent results after isolated aortic valve replacement. Despite relevant differences in gradients, long-term survival was comparable with the expected normal survival for both bioprostheses. Patients with a porcine heart valve had a higher postoperative transvalvular gradient.