A new, two-channel instrument for simultaneous NO3 and N2O5 monitoring was used to make the first comprehensive set of nocturnal NOx measurements (NO, NO2, NO3 and N2O5) at the Taunus Observatory, a rural mountain site (Kleiner Feldberg) in South-western Germany. In May 2008, NO3 and N2O5 mixing ratios were well above the instrumental detection limit (a few ppt) on all nights of the campaign and were characterised by large variability resulting from inhomogeneously distributed sinks. The concentrations of NO3, N2O5 and NO2 were consistent with the equilibrium constant, K2, defining the rates of formation and thermal dissociation of N2O5. A steady-state lifetime analysis showed that nocturnal NOx losses were generally dominated by reaction of NO3 with volatile organic compounds in this forested region, with N2O5 uptake to aerosols of secondary importance. Analysis of a limited dataset obtained at high relative humidity indicated that the loss of N2O5 by reaction with water vapour is less efficient (> factor 3) than derived using laboratory kinetic data. The fraction of NOx present as NO3 and N2O5 reached ≈20% on some nights, with night-time losses of NOx competing with daytime losses.
A new, two-channel instrument for simultaneous NO3 and N2O5 monitoring was used to make the first comprehensive set of nocturnal NOx measurements (NO, NO2, NO3 and N2O5) at the Taunus Observatory, a rural mountain site (Kleiner Feldberg) in South-western Germany. In May 2008, NO3 and N2O5 mixing ratios were well above the instrumental detection limit (a few ppt) on all nights of the campaign and were characterised by large variability. The concentrations of NO3, N2O5 and NO2 were consistent with the equilibrium constant, K2, defining the rates of formation and thermal dissociation of N2O5. A steady-state lifetime analysis is consistent with the loss of nocturnal NOx being dominated by the reaction of NO3 with volatile organic compounds in this forested region, with N2O5 uptake to aerosols of secondary importance. Analysis of a limited dataset obtained at high relative humidity indicated that the loss of N2O5 by reaction with water vapour is less efficient (>factor 3) than derived using laboratory kinetic data. The fraction of NOx present as NO3 and N2O5 reached ~20% on some nights, with night-time losses of NOx competing with daytime losses.
We present an estimation of the uptake coefficient (γ) and yield of nitryl chloride (ClNO2) (f) for the heterogeneous processing of dinitrogen pentoxide (N2O5) using simultaneous measurements of particle and trace gas composition at a semi-rural, non-coastal, mountain site in the summer of 2011. The yield of ClNO2 varied between (0.035 ± 0.027) and (1.38 ± 0.60) with a campaign average of (0.49 ± 0.35). The large variability in f reflects the highly variable chloride content of particles at the site. Uptake coefficients were also highly variable with minimum, maximum and average γ values of 0.004, 0.11 and 0.028 ± 0.029, respectively, with no significant correlation with particle composition, but a weak dependence on relative humidity. The uptake coefficients obtained are compared to existing parameterisations based on laboratory datasets and with other values obtained by analysis of field data.
We present an estimation of the uptake coefficient (γ) and yield of nitryl chloride (ClNO2) (f) for the heterogeneous processing of dinitrogen pentoxide (N2O5) using simultaneous measurements of particle and trace gas composition at a semi-rural, non-coastal, mountain site in the summer of 2011. The yield of ClNO2 varied between (0.035 ± 0.027) and (1.38 ± 0.60) with a campaign average of (0.49 ± 0.35). The large variability in f reflects the highly variable chloride content of particles at the site. Uptake coefficients were also highly variable with minimum, maximum and average γ values of 0.004, 0.11 and 0.028 ± 0.029, respectively, with no significant correlation with particle composition, but a weak dependence on relative humidity. The uptake coefficients obtained are compared to existing parameterizations based on laboratory datasets and with other values obtained by analysis of field data.