With the discovery of light beyond human visibility, scientists strove to extend the range of observation to invisible parts of the light’s spectrum. Realising that light of all frequencies is part the same physical phenomenon, brought a leap in understanding about electromagnetic waves. With the development of more advanced technology, detectors with higher sensitivity for adjacent frequencies to the visible were built. From this, with each new observable wavelength, more insight into otherwise invisible processes and phenomenons were observed. Hand in hand with this went the enhancement of the output power of corresponding sources. This has lead to higher sensitivity setups throughout the spectrum, leading to observations which have given a deeper understanding in various fields of science. Nowadays, detectors and emitters in many different regions of the invisible electro magnetic spectrum have found their way in our every day life. Innovations in technology has lead to practical applications such as X-rays in medicine, motion sensors and remote controls using infrared light, distance sensors and data transmission using radar and radio devices. The frequency regions above infrared are optically generated and below radar can be produced using electric methods. There is no straight line that separates these frequencies. There rather is a whole intermediate region known as the terahertz (THz) regime. Due to the lack of sensitive detectors and efficient sources, the THz frequency region has not been exploited for application use on a widespread basis so far. It combines properties from the surrounding frequency ranges which make it an ideal spectrum for various applications. Consequently, THz radiation and THz imaging are active fields of research.
The work presented in this thesis consists of the development and testing of novel THz imaging concepts, which uses a THz antenna coupled field effect transistor (TeraFET) detector. Two detection principles are applied using two different optical setups. The first uses a pulsed optical parametric oscillator (OPO) THz source where the optical output power is detected. The source relies on a nonlinear effect of a lithium niobate crystal to generate tunable THz pulses from a Q-switched pump laser. The THz signal is detected and amplified by a double stage operational amplifier for monitoring the real time 20 ns pulses on an oscilloscope where a signal to noise ratio (SNR) of ⇠ 25 at a frequency range from 0.75 to 1.1 THz is reached. Imaging of the area of interest with a resolution of 1.2 mm is achieved through raster scanning of the THz pulses. Also spectroscopy with a frequency resolution of ⇠ 50 GHz is demonstrated using a para-aminobenzoic acid sample. The second setup utilises two synchronised electronic multiplier chain sources where their output is mixed on the detector. To form a heterodyne detection setup, the intermediate frequency is fed to a lock-in amplifier which then amplifies the so called beat signal from the TeraFET detector. One source is fixed relative to the detector even through scanning to ensure a stable signal. This detection method allows for amplitude and phase detection for every scanning position, making numerical light field propagation and object reconstruction possible. Numerical focussing is a key feature achieving a lateral resolution of the input transmittance of ⇡ 2 mm.
After the introduction, the second chapter describes the setup, measurement results and challenges which arise using a TeraFET together with the pulsed THz source “Firefly-THz”. In the description of the setup, special attention is given to the shielding of the detector and the electronics. General findings discuss first the overall performance and later spectroscopy and imaging as application examples. Another subsection continues with potential noise sources before the chapter is concluded. Chapter three expands on the topic of Fourier optics from a theoretical point of view. First, parts of the theory of the Fourier Transform (FT) are set out for the reader and how the Fast Fourier Transform (FFT) results from the Discrete Fourier Transform (DFT). This approach is used for theoretical considerations and the implementation of a Fourier optic script that allows for numerical investigations on electro magnetic field propagation through an optical system. The boundary conditions are chosen to be practical relevant to make predictions on measurements presented in chapter four. The following fourth chapter describes the realisation of a heterodyne THz detection setup. Before the measurement results are presented, the setup and its electric configuration are shown. The results come close to the analytical predictions so that the same algorithm which propagates the field from an object to the Fourier plane is used to propagate the measured field back to the object. The influence of phase noise on the measurement results are discussed before simulation and measurement is compared. The last chapter in this thesis concludes on the findings in the pulsed THz detection and the heterodyne THz Fourier imaging and gives an outlook for both configurations.
This thesis is concerned with systematic investigations of electronic noise in novel condensed matter systems. Although fluctuations are frequently considered a nuisance, that is, a disturbance limiting the accuracy of scientific measurements, in many cases they can reveal fundamental information about the inherent system dynamics. During the past decades, the study of electronic fluctuations has evolved into an indispensable tool in condensed matter physics.
The focus of the present work lies both in a further development of the fluctuation spectroscopy technique and in the study of materials of current interest. In particular, a comprehensive study of the charge carrier dynamics in the archetypal diluted magnetic semiconductors (Ga,Mn)As and (Ga,Mn)P was performed. In spite of extensive research work carried out during the last years, there still exists no theoretical consensus on the precise mechanism of ferromagnetic order and the electronic structure in these materials. Moreover, disorder and correlation effects complicate the understanding of these compounds.
Fluctuation spectroscopy experiments presented in this work provide strong evidence that a percolation transition is observed in samples with localized charge carriers, since the normalized resistance noise magnitude displays a significant enhancement around the Curie temperature. In addition, this quantity exhibits a power law scaling behavior as a function of the resistance, which is in good agreement with theoretical models of percolating systems.
By contrast, it was found that the resistance noise in metallic samples is mainly dominated by the physics of defects such as manganese interstitials and arsenic antisites. Furthermore, first noise studies were carried out on hafnia- and yttria-based resistive random access memories. In these memristor devices, the rupture and re-formation of oxygen deficient conducting filaments caused by the electric field and Joule heating driven motion of mobile anions lead to an unusual resistance switching behavior. For the first time, comparative noise measurements on oxygen deficient and stoichiometric hafnium oxide devices, as well as on novel yttrium oxide based devices were performed in this work. Finally, new strategies for noise measurements of highly insulating and extremely low-resistive samples were developed and realized. In detail, an experimental setup for the measurements of dielectric polarization fluctuations in insulating systems was designed and successfully tested. Here, the polarization noise of a sample is measured as current or voltage fluctuations produced within a capacitance cell. The study of dielectric polarization noise allows for conclusions to be drawn regarding equilibrium structural dynamics in insulators such as relaxor ferroelectrics. On the other hand, as successfully demonstrated for a heavy-fermion compound, focused ion beam etching enables to introduce a meander-shaped geometry in single crystal platelets, in order to strongly enhance the sample resistance and thus make resistance noise measurements possible. First results indicate a connection of the noise properties with the Kondo effect in the investigated material.
Die Bestrahlung atmungsbewegter Tumoren stellt eine Herausforderung für die moderne Strahlentherapie dar. In der vorliegenden Arbeit werden zu Beginn die physikalischen, technischen und medizinischen Grundlagen vorgestellt, um dem Leser den Einstieg in die komplexe Thematik zu erleichtern. Des Weiteren werden verschiedene Techniken zur Bestrahlung atmungsbewegter Zielvolumina vorgestellt. Auch wird auf die Sicherheitssäume eingegangen, die notwendig sind, um Fehler in der Bestrahlungskette beim Festlegen des Planungszielvolumens für die Bestrahlung auszugleichen.
Im Rahmen dieser Arbeit wurde ein Konzept entwickelt, wodurch sich der Sicherheitssaum von bewegten Tumoren in der Radiochirurgie mit dem Tumor-Tracking-System des Cyberknifes noch weiter verkleinern lässt. Somit kann die sogenannte therapeutische Breite der Behandlung weiter vergrößert werden kann. Dafür wurden ein 4D-CT und ein Gating-System in den klinischen Betrieb aufgenommen. Die entwickelte Technik basiert auf den zehn individuellen Atemphasen des 4D-CTs und lässt eine Berücksichtigung bewegter Risikostrukturen bereits während der Bestrahlungsplanung zu. Diese Methode wurde mit aktuellen Bestrahlungstechniken mittels eines Vergleichs der Bestrahlungspläne anhand von zehn Patientenfällen verglichen. Zur Erstellung der Bestrahlungspläne kamen die Bestrahlungsplanungssysteme von Varian (Eclipse 13.5) und Accuray (Multiplan 4.6) zum Einsatz. Es wurden insbesondere die Bestrahlungsdosen an den Risikoorganen und die Volumina ausgewählter Isodosen betrachtet. Hier zeigte sich eine klare Abhängigkeit von der Belastung des gesunden Gewebes von der verwendeten Bestrahlungstechnik. Dies lässt die Schlussfolgerung zu, dass mit einer Reduzierung des Sicherheitssaums, welcher abhängig von der verwendeten Planungs- und Bestrahlungstechnik ist, eine Vergrößerung der therapeutischen Breite einhergeht. Zusätzlich bleibt bei einer geringen Belastung des umliegenden gesunden Gewebes die Möglichkeit für eine weitere Bestrahlung offen.
Anschließend wurden anhand von berechneten Testplänen Messungen an einem für diese Arbeit modifizierten Messphantom am Varian Clinac DHX und am Cyberknife VSI durchgeführt. Hier wurden die beim Planvergleich verwendeten Bestrahlungstechniken verwendet, um einen Abgleich von berechneter und tatsächlich applizierter Dosis zu erhalten. Das verwendete Messphantom simuliert die Atmung des Patienten und lässt gleichzeitig eine Verifikation der Dosisverteilung mit EBT3-Filmen sowie Messungen mit Ionisationskammern zu. Es zeigte sich, dass für die Techniken, welche aktiv die Atmung berücksichtigen (Synchrony am Cyberknife und Gating am Varian Clinac), selbst im Niedrigdosisbereich eine gute Übereinstimmung zwischen Messung und Berechnung der Dosisverteilung vorliegt. Sobald die Bewegung des Zielvolumens bereits bei der Bestrahlungsplanung berücksichtigt wird, steigt die Übereinstimmung weiter an. Für Techniken, welche die Atmung lediglich bei der Zielvolumen-Definition einbeziehen (ITV-Konzept), liegen sowohl die mit Ionisationskammern gemessenen Werte als auch die Übereinstimmung von berechneter und gemessener Dosisverteilung außerhalb des Toleranzbereichs.
Eine weitere Frage dieser Arbeit befasst sich mit der Treffsicherheit des Tumor-Tracking-Systems des Cyberknifes (Synchrony). Hier wurden Messungen mit dem XSightLung-Phantom und unterschiedlichen Sicherheitssäumen, welche die Bewegung des Tumors ausgleichen sollen, durchgeführt. Dies geschah sowohl mit dem für das Phantom vorgesehenen Würfel mit Einschüben für EBT3-Filme als auch mit einem Film-Sanchwich aus Flab-Material zur Untersuchung einer dreidimensionalen Dosisverteilung. Die Analyse der Filme ergab, dass es zumindest an einem Phantom mit einer einfachen kraniokaudalen Bewegung nicht nötig ist, die Bewegung des Zielvolumens durch einen asymmetrischen Sicherheitssaum in Bewegungsrichtung zu kompensieren um die Abdeckung des Zielvolumens mit der gewünschten Dosis zu gewährleisten.
Durch diese Arbeit konnten zusätzlich weitere wertvolle Erkenntnisse für den klinischen Alltag gewonnen werden: bei der Untersuchung der Bewegung von Tumoren in freier Atmung sowie bei maximaler Inspiration und Exspiration zeigte sich, dass zum Teil die Tumorbewegung in maximalen Atemlagen (3-Phasen-CT) deutlich von der freien Atmung abweicht. Dies lässt den Schluss zu, dass für eine Bestrahlung in freier Atmung ein 4D-CT die Tumorbewegung deutlich realistischer widerspiegelt als ein 3-Phasen-CT, zumal letzteres eine größere Dosisbelastung für den Patienten bedeutet.
Ebenfalls konnte anhand einer retrospektiven Untersuchung von Lungentumoren gezeigt werden, dass für die Berechnung von Bestrahlungsplänen für Tumoren in inhomogenem Gewebe der Ray-Tracing-Algorithmus die Dosis im Zielvolumen teilweise sehr stark überschätzt. Um eine realistische Dosisverteilung zu erhalten, sollte deshalb insbesondere bei Tumoren in der Lunge auf den Monte-Carlo-Algorithmus zurückgegriffen werden.
This thesis presents the first measurement of the proton capture reaction on the isotope 124Xe performed in inverse kinematics. The experiment was carried out in June 2016 at the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany.
124Xe is one of about 35 p-nuclei that cannot be produced via neutron-induced nucleo- synthesis as the vast majority of heavy elements. Its production and destruction provide important information about the nucleosynthesis of the p-nuclei. Measuring the 124Xe(p,g)125Cs reaction also gives strong constraints for its reverse 125Cs(g,p)124Xe reaction.
Fully stripped 124Xe ions repeatedly passed a H2 gas jet target at five different energies between 5.5 MeV/u and 8 MeV/u. An electron cooler compensated for the energy loss in the target and reduced the beam momentum spread. The reaction product 125Cs55+ has a smaller magnetic rigidity than 124Xe54+. Therefore 125Cs55+ was deflected towards smaller radii in the first dipole after the target area and thereby separated from 124Xe54+. It was detected with a position-sensitive Double-Sided Silicon Strip Detector (DSSSD). The novelty of this experiment was the installation of the DSSSD inside the ultra-high vacuum of the storage ring using a newly designed manipulator.
Three High-Purity Germanium X-ray detectors were used to measure the X-rays following the Radiative Electron Capture (REC) events into 124Xe53+. The REC cross sections are well-known and were used to determine the luminosity.
The 124Xe(p,g)125Cs cross sections at ion beam energies between 5.5 MeV/u and 8 MeV/u were determined relatively to the K-REC cross sections and finally compared to the theoretically predicted cross sections. While theoretical predictions of the TENDL database are lower than the measured ones by a factor of up to seven, the NON-SMOKER data are higher by a factor of up to two, except of the cross section at 7 MeV/u, where NON-SMOKER data are slightly lower than the experimental value.
For the first time, a proton capture cross section could be measured in inverse kinematics close to the astrophysically relevant Gamow window. This allows the direct determination of the (p,g) cross section of isotopes with half-lives down to several minutes, which is not possible with any other technique.
Quantum chromodynamics (QCD) is the theory of the strong interaction between quarks and gluons. Due to Confinement, at lower energies quarks and gluons are bound into colorless states called hadrons. QCD is also asymptotically free, i.e. at large energies or densities it enters a deconfined state, termed quark-gluon plasma (QGP), where quarks and gluons are quasi-free. This transition occurs at an energy scale around 200 MeV where QCD cannot be treated perturbatively. Instead it can be formulated on a space-time grid. The resulting theory, lattice quantum chromodynamics (LQCD), can be simulated efficiently on high performance parallel-computing clusters. In recent years graphic processing units (GPUs), which outperform CPUs in terms of parallel-computing and memory bandwidth capabilities, became very popular for LQCD computations. In this work the QCD deconfinement transition is studied using CL2QCD, a LQCD application that runs efficiently on GPUs. Furthermore, CL2QCD is extended by a Rational Hybrid Monte Carlo algorithm for Wilson fermions to allow for simulations of an odd number of quark flavors.
Due to the sign-problem LQCD simulations are restricted to zero or very small baryon densities, where, in the limit of infinite quark mass QCD has a first order deconfinement phase transition associated to the breaking of the global centre symmetry. Including dynamical quarks breaks this symmetry explicitly. Lowering their mass weakens the first order transition until it terminates in a second order Z2 point. Beyond this point the transition is merely an analytic crossover. As the lattice spacing is decreased, the reduction of discretization errors causes the region of first order transitions to expand towards lower masses. In this work the deconfinement critical point with 2 and 3 flavors of standard Wilson fermions is studied. To this end several kappa values are simulated on temporal lattice extents 6,8,10 (4) for two flavors (three flavors) and various aspect ratios (spatial lattice extent / temporal lattice extent) so as to extrapolate to the thermodynamic limit, applying finite size scaling. For two flavors an estimate is done if and when a continuum extrapolation is possible.
The chiral and deconfinement phase transitions at zero density for light and heavy quarks, respectively, have analytic continuations to purely imaginary chemical potential, where no sign-problem exists and LQCD simulations can be applied. At some critical value of the imaginary chemical potential, the transitions meet the endpoint of the Roberge-Weiss transition between adjacent Z3 sectors. For light and heavy quarks the transition lines meet in a triple point, while for intermediate masses they meet in a second order point. At the boundary between these regimes the junction is a tricritical point, as shown in studies with two and three flavors of staggered and Wilson quarks on lattices with a temporal lattice extent of 4. Employing finite size scaling the nature of this point as a function of the quark mass is studied in this work for two flavors of Wilson fermions with a temporal lattice extent of 6. Of particular interest is the change of the location of tricritical points compared to an earlier study on lattices with temporal extent of 4.
Most of the elements in the universe are produced via charged-particle fusion reactions during the primordial nucleosynthesis and different stellar burning stages, as well as via neutron-capture reactions. Around 35 heavy, proton-rich isotopes are bypassed by those reaction paths, the p nuclei. A series of photo-disintegration reactions occurring in supernovae, called the γ process, was suggested as a mechanisms to produce the p nuclei. Numerical simulations of the γ process have been unable to reproduce the observed abundances of the light p isotopes. Recent models showed that a series of proton capture reactions could provide the observed abundances. Hence, the cross sections of the crucial capture reactions have to be measured in order to test those assumptions.
Radiative proton captures in addition to the γ-process could reproduce the observed abundance pattern. This thesis presents preparations of a proton capture measurement on the radioactive 91Nb in standard kinematics with a calorimetric 4π setup. The 91Nb(p,γ)92Mo reaction might be the key to explain the production of one of the most abundant p-nuclei, 92Mo. So far, no experimental data for this reaction is available.
We produced a sample of 91Nb, with a half-life of 680 yr, at the Physikalisch Technische Bundesanstalt in Braunschweig, Germany, by irradiating 92Mo with protons in the energy range of 12 – 20MeV. 91Nb was produced via the reaction 92Mo(p,2p)91Nb and via 92Mo(p,pn)91Mo, where 91Mo decays to 91Nb with a half-life of 15.5min. To predict the amount of produced 91Nb the cross section of 92Mo(p, 2p) was measured. It was found to be higher than the value given by theoretical calculations with TALYS. Finally, 91Nb was chemically separated from the molybdenum carried at Paul-Scherrer- Institut, Villigen, Switzerland.
In-beam total absorption cross-section measurement of the reaction 91Nb(p,γ)92Mo with 2 MeV protons at FRANZ is planed with the produced 91Nb. A 4π BaF2 detector consisting of 41 crystals will be used. During this experiment we will measure the sum energy and the multiplicity of each event. The freshly produced 91Nb constitutes only a minor component of the sample material. The sum energy and multiplicity are crucial to distinguish the desired 91Nb(p,γ) from all the other more dominant reactions. The expected multiplicity and the efficiency of the setup were carefully simulated with DICEBOX and GEANT4. It was possible to show that background reactions can be effectively suppressed. The most important background contributions could be identified and result from 92Mo(p,γ), 19F(p,γ), and 19F(p,α).
Compact objects - black holes and neutron stars - are fascinating objects, not only for the astrophysicists, but for a wide range of researchers, including astronomers, theoretical physicists, particle and nuclear physicists, condensed matter physicists and arguably for the layman as well.
First theorized in the first part of the twentieth century, for a long time these objects have been considered just exotic ideas or mathematical curiosities. Pulsar were however detected in the late 1960s and readily identified as rotating, radiating neutron stars, while the first candidate black hole, Cygnus X-1, was observed in 1972. Since then the interest in these objects has steadily grown.
The reasons behind this interest are easily understood considering that compact object dwell at the intersection of many different areas of physics, and are ideal laboratories to explore the interplay between these areas.
Black holes, which are purely gravitational objects, are perfectly suited to study the nature of gravity, its manifestations such as gravitational waves, and the differences between various theories of gravity in the regime where they are expected to be most relevant, i.e. the strong field regime. However, just like any massive astrophysical object, black holes are interested by accretion phenomena, which are thought to be the power source of some very bright astrophysical emitters of electromagnetic signals, such as active galactic nuclei or X-ray binaries.
At the same time, black holes exist in a variety of different mass scales, from stellar mass to supermassive black holes billions of times heavier. The latter play a very important and yet not fully understood role in the formation and evolution of galaxies, as well as in shaping the large scale structure of the universe, making them relevant to cosmology as well.
Neutron stars share with black holes the characteristic of being gravitationally dominated systems; but because they are composed of baryon matter, they display a much richer behaviour. It has been realized early on that the matter in neutron star cores reaches extreme densities, exceeding the one in atomic nuclei. This means that neutron stars could provide invaluable information on the behaviour of matter in such extreme conditions (which are impossible to achieve in laboratory experiments), such as details of the nucleonic interaction, the properties of hyperons or of quark-gluon plasmas.
...
Für das bessere Verständnis der Nukleosynthese der schweren Elemente im s-Prozess wurde im Rahmen dieser Arbeit die Messung zur Bestimmung der Neutroneneinfangsreaktion von 83Kr durchgeführt. Als Messinstrument wurde DANCE am LANL verwendet, ein 4pi-Kalorimeter zur Detektion der entstehenden g-Kaskaden bei (n,g)-Reaktionen. Darüber hinaus wurden außerdem noch Proben mit 85Kr und 86Kr vermessen.
Die Herausforderung an diesem Experiment bestand vor allem in der Probenherstellung. Das Edelgas Kr erforderte eine Neukonstruktion der normalerweise bei DANCE verwendeten Probenhalterung. Das Hauptaugenmerk lag auf der Maximierung der Kr-Exposition durch den Neutronenstrahl. Im Gegenzug wurde versucht das umgebende Material nach Möglichkeit keinen Neutronen auszusetzen. Für die Isotope 83,86Kr wurden Hochdruckgaskugeln verwendet, die an der Goethe-Universität Frankfurt gefüllt und in eine der neuen Probenhalterungen eingesetzt wurden. Zur Beachtung des bei der Messung entstehenden Untergrundes wurde eine Messung mit baugleicher Probenhalterung und leerer Gaskugel durchgeführt. Da bereits kleine Mengen 85Kr eine hohe Radioaktivität aufweisen, wurde eine in einen Stahlzylinder eingeschweißte, existierende Quelle verwendet.
Bei der Analyse zu 86Kr wurde schnell eine zu starke Verunreinigung der Kr-Probe mit Xe offensichtlich, einen signifikanten Anteil des Spektrums ausmachte. Aus diesem Grund kam es vor allem zu Problemen den korrekten Untergrund von den 86Kr Messdaten zu subtrahieren. Die weitere Bestimmung inklusive Streukorrekturen, Normierung anhand des Flussmonitors und DICEBOX/GEANT3 Effizienzbestimmung lieferte zwar einen energieabhängigen Wirkungsquerschnitt, dieser zeigte allerdings große Abweichungen von den evaluierten ENDF/B-VII.1 Daten, was besonders ersichtlich in der deutlichsten 86Kr Resonanz bei 5515 eV zu erkennen war. Aus diesem Grund konnte aus den Messdaten kein MACS extrahiert werden.
Bei einer Untersuchung der Aktivität der 85Kr-Probe mit Hilfe der einzelnen BaF2-Detektoren in der DANCE Kugel zeigte sich zunächst eine um fast einen Faktor vier geringere Aktivität als vom Hersteller angegeben. Auch bei der weiteren Analyse traten massive Untergrundprobleme auf. Die Form des Stahlzylinders, in dem das Kr-Gasgemisch eingeschweißt war, konnte aufgrund seiner Form nur schwer im Strahlrohr untergebracht werden. Beim Experiment selbst zeigte sich dann, dass Teile der Halterung vom Neutronenstrahl getroffen wurden, was einen Untergrund mit sehr hohem Q-Wert erzeugte, der nicht durch ein Esum Fenster entfernt werden konnte. Durch eine Beschädigung der Halterung mit der Probe kam es darüber hinaus zu Abweichungen mit der verwendeten Leerhalterung. All das führte trotz einer langen Messzeit von fast 18 d dazu, dass nur ein sehr schwaches Signal von der eigentlichen Kr-Probe zu erkennen war. Es wurde eine mögliche 85Kr Resonanz bei 675 eV gefunden, allerdings ist die endgültige Zuordnung aufgrund der nicht eindeutigen Untergrundsituation äußerst schwierig. Im Vorfeld des Kr-Experimentes wurde eine Messung von RbCl an DANCE durchgeführt, da ursprünglich zu erwarten war, dass bereits ein Teil des 85Kr zu 85Rb zerfallen war. Durch diese Messung sollte dieser Anteil leicht von der späteren Messung zu subtrahieren sein. Allerdings trat ein unerwartetes Problem während der Datenaufnahme auf. Die Verbindung der DAQ Boards wurde getrennt, wodurch ca. 3/4 der Detektoren nicht mehr zeitsynchron liefen. Im Zuge dieser Arbeit wurde eine Rekonstruktion dieser Daten angestrebt. Durch Modifikationen am FARE Code, der zur Auswertung verwendet wurde, konnte Flugzeitspektren für jeden Beschleunigerpuls erzeugt werden. Es zeigte sich zunächst ein offensichtlicher Trend einer Verschiebung der getrennten Boards zu späteren Zeiten. Durch mehrere Fits an die Abweichungsverteilung und anschließende Korrektur konnte zunächst ein Spektrum wiederhergestellt werden, das vergleichbar mit den unbeschädigten Daten war. Bei einer detaillierten Analyse dieser neu gewonnen Daten zeigte sich jedoch eine Nichtlinearität in der Zeitverschiebung. Dies resultierte letztlich in einer Korrektur des Spektrums, allerdings nicht in einem Koinzidenzfenster von 10 ns, das für eine Wirkungsquerschnittsanalyse notwendig ist. Es wurde geschlussfolgert, dass durch die geringe Statistik in den einzelnen Flugzeitspektren solch eine Genauigkeit nicht zu erreichen ist.
Die Messung des Neutroneneinfangsquerschnitts von 83Kr konnte im Zuge dieser Arbeit erfolgreich durchgeführt werden. Es wurden zwei Messungen mit verschiedenen Strömen kombiniert. Eine Messung mit 40 µA wurde durchgeführt, um Pile-Up in der größten Resonanz bei 28 eV zu reduzieren. Die zweite Messung diente dann dem Sammeln von ausreichend Statistik in den nicht resonanten Bereichen. Die eingesetzte Leerkugel erlaubte eine saubere Subtraktion des Untergrundes von Probenhalterung, Gaskugel und Umgebung. Für die Skalierung der Messergebnisse wurde eine weitere Messung mit einer 5000 Å dicken Goldfolie durchgeführt. Zur Bestimmung der Detektoreffizienz konnten zunächst die durch den Neutroneneinfang entstandenen Abregungskaskaden der 84Kr Kerne mit DICEBOX modelliert werden. Diese Kaskaden wurden dann anschließend in GEANT3 Simulationen verwendet, um die Effizienz bestimmen zu können. Mit diesen Methoden erhielt man die Maxwell-gemittelten Wirkungsquerschnitte von kT = 5 keV - 100 keV. Bei der für den s-Prozess wichtigen Temperatur von kT = 30 keV wurde der Querschnitt bestimmt zu: MACS (30 keV) = (256,6 +- 14,2 (stat) +- 18,1(sys)) mb.
Dieser Wert ist in guter Übereinstimmung mit dem in der KADoNIS v0.3 Datenbank angegebenen Wert von MACS;KADoNIS (30 keV) = (243 +- 15) mb. Mit den so gewonnenen Wirkungsquerschnitten wurden außerdem die Reaktionsraten berechnet. Bei den anschließenden Netzwerkrechnungen mit dem Programm NETZ wurden die Auswirkungen der in dieser Arbeit gewonnenen Wirkungsquerschnitte im Vergleich zu den KADoNIS v0.3 Werten betrachtet. Dabei zeigte sich eine leicht erhöhte Produktion der stabilen Isotope 84Kr, 86Kr, 85Rb und 87Rb, sowie eine leichte Unterproduktion der stabilen Isotope 86-88Sr in der Hauptkomponente des s-Prozess. Ein ähnliches Bild zeigte sich in der He-Brennphase der schwachen Komponente. Der in dieser Arbeit gemessene Wirkungsquerschnitt bei hohen Temperaturen ist geringer als der in KADoNIS v0.3 angegebene, weswegen es bei der Simulation mit NETZ zu einer stark erhöhten Produktion von 83Kr in der C-Brennphase kommt.
Most of the elements heavier than iron are produced through neutron capture reactions in the s- and r -process. The overall path of the s-process is well understood and can be accurately reproduced in network simulations. However, there are still some neutron capture reactions of unstable nuclei involved in the s-process, which were not yet measured due to the difficulty in producing suitable targets. In those cases, theoretical models have to be used to estimate the missing cross section.
One example is the branching point nucleus 86Rb, whose neutron capture cross section cannot be directly measured due to its short half life of 18.86 days. It is, however, also possible to measure its inverse, the 87Rb(g,n) reaction in order to obtain the 86Rb(n,g) cross section through the principle of detailed balance.
Natural rubidium was irradiated with a quasi-monoenergetic photon beam in the energy range between 10.7 MeV and 16 MeV in order to investigate the photo-dissociation cross section of 87Rb. The results are presented in this thesis. Not only the total cross section of 87Rb(g,n), but also the partial production cross section of the ground and isomeric state of 84Rb through the 85Rb(g,n) reaction was measured.
Not all isotopes can be reached via neutron capture reaction, and are therefore bypassed by the s- and r -process. These 35 proton-rich isotopes are called p-nuclei and are produced in the γ-process by a chain of photo-disintegration reactions in Type II supernovae. Network calculations of Type II supernova show that the γ-process can explain the production of most p-nuclei, but some – especially 92/94Mo and 96/98Ru – are heavily underproduced. While this could be the result of deficiencies in the corresponding stellar models or insufficient knowledge of the involved reaction rates, it is also possible that the missing p-nuclei are synthesized in other production scenarios.
An alternative scenario for 92Mo is the production via a chain of proton capture reactions in Type Ia supernovae. One important reaction in this chain is the 90Zr(p,g) reaction. The reaction cross section was already measured several times, but the results were inconclusive. In the present work, the 90 Zr(p,g) reaction was measured using the in-beam gamma-ray spectroscopy technique and the discrepancies between the data sets could be largely explained.