Refine
Year of publication
- 2020 (3) (remove)
Document Type
- Article (3)
Language
- English (3) (remove)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- Epilepsy (1)
- Fracture (1)
- Morbidity (1)
- Seizure (1)
- Shoulder luxation (1)
- antiseizure (1)
- behavioral adverse events (1)
- drug‐resistant epilepsy (1)
- focal seizures (1)
- noninterventional (1)
Institute
- Medizin (3) (remove)
Objective: To evaluate the incidence and risk factors of generalized convulsive seizure (GCS)-related fractures and injuries during video-EEG monitoring.
Methods: We analyzed all GCSs in patients undergoing video-EEG-monitoring between 2007 and 2019 at epilepsy centers in Frankfurt and Marburg in relation to injuries, falls and accidents associated with GCSs. Data were gathered using video material, EEG material, and a standardized reporting form.
Results: A total of 626 GCSs from 411 patients (mean age: 33.6 years; range 3–74 years; 45.0% female) were analyzed. Severe adverse events (SAEs) such as fractures, joint luxation, corneal erosion, and teeth loosening were observed in 13 patients resulting in a risk of 2.1% per GCS (95% CI 1.2–3.4%) and 3.2% per patient (95% CI 1.8–5.2%). Except for a nasal fracture due to a fall onto the face, no SAEs were caused by falls, and all occurred in patients lying in bed without evidence of external trauma. In seven patients, vertebral body compression fractures were confirmed by imaging. This resulted in a risk of 1.1% per GCS (95% CI 0.5–2.2%) and 1.7% per patient (95% CI 0.8–3.3%). These fractures occurred within the tonic phase of a GCS and were accompanied by a characteristic cracking noise. All affected patients reported back pain spontaneously, and an increase in pain on percussion of the affected spine section.
Conclusions: GCSs are associated with a substantial risk of fractures and shoulder dislocations that are not associated with falls. GCSs accompanied by audible cracking, and resulting in back pain, should prompt clinical and imaging evaluations.
Purpose: In the clinical routine, detection of focal cortical dysplasia (FCD) by visual inspection is challenging. Still, information about the presence and location of FCD is highly relevant for prognostication and treatment decisions. Therefore, this study aimed to develop, describe and test a method for the calculation of synthetic anatomies using multiparametric quantitative MRI (qMRI) data and surface-based analysis, which allows for an improved visualization of FCD.
Materials and Methods: Quantitative T1-, T2- and PD-maps and conventional clinical datasets of patients with FCD and epilepsy were acquired. Tissue segmentation and delineation of the border between white matter and cortex was performed. In order to detect blurring at this border, a surface-based calculation of the standard deviation of each quantitative parameter (T1, T2, and PD) was performed across the cortex and the neighboring white matter for each cortical vertex. The resulting standard deviations combined with measures of the cortical thickness were used to enhance the signal of conventional FLAIR-datasets. The resulting synthetically enhanced FLAIR-anatomies were compared with conventional MRI-data utilizing regions of interest based analysis techniques.
Results: The synthetically enhanced FLAIR-anatomies showed higher signal levels than conventional FLAIR-data at the FCD sites (p = 0.005). In addition, the enhanced FLAIR-anatomies exhibited higher signal levels at the FCD sites than in the corresponding contralateral regions (p = 0.005). However, false positive findings occurred, so careful comparison with conventional datasets is mandatory.
Conclusion: Synthetically enhanced FLAIR-anatomies resulting from surface-based multiparametric qMRI-analyses have the potential to improve the visualization of FCD and, accordingly, the treatment of the respective patients.
Objective To evaluate the success of initiation of adjunctive brivaracetam in patients who required a change in antiepileptic drug (AED) regimen and substituted at least one AED with brivaracetam. Methods In this retrospective noninterventional study conducted in specialized epilepsy centers across Germany, patients initiated adjunctive brivaracetam between February 15, 2016, and August 31, 2016, as part of an intended change in AED regimen. The primary effectiveness variable was the proportion of patients who continued on brivaracetam after 3 months, and withdrew at least one AED either before or within 6 months after brivaracetam initiation. Results Five hundred and six patients had at least one brivaracetam dose and were included in the safety set (SS). Four hundred and seventy patients started to reduce the dose of one AED before/after brivaracetam initiation, had at least one concomitant AED at brivaracetam initiation, and were included in the full analysis set (FAS) for effectiveness analyses. At baseline, patients had a median of seven lifetime AEDs and a median of 3.8 seizures/28 days. In the SS, 85.2% of patients withdrew one AED before/after initiation of brivaracetam, most commonly levetiracetam (49.4%). 46.2% of patients substituted another AED with brivaracetam within 24 hours (fast withdrawal). The proportions of patients (FAS) who continued on brivaracetam after 3 and 6 months and withdrew one AED were 75.5% and 46.6%, respectively. After 6 months, 32.1% of patients were 50% responders; 13.0% were seizure‐free. In the SS, 34.6% of patients reported treatment‐emergent adverse events (TEAEs); 21.9% had TEAEs that were assessed by the treating physician as drug‐related. Incidences of behavioral AEs before (3‐month baseline) and after brivaracetam initiation in patients who withdrew levetiracetam were 19.2% and 8.0%, respectively (5.0% and 7.7% in patients who withdrew other AEDs). Significance Brivaracetam was effective and well‐tolerated in patients who required a change in AED drug regimen and initiated adjunctive brivaracetam in German clinical practice.