Refine
Has Fulltext
- yes (17)
Is part of the Bibliography
- no (17)
Keywords
- TAVI (4)
- aortic stenosis (4)
- algorithm (2)
- ACURATE neo (1)
- ADGRE1 (1)
- Aortic stenosis (1)
- Aortic valve (1)
- Barlow disease (1)
- Blood pressure (1)
- Body mass index (1)
Institute
- Medizin (17) (remove)
We present the case of an adult male patient with an incomplete form of Shone’s complex associated with bicuspid aortic valve and a double orifice mitral valve. Intraoperative inspection of the mitral valve showed double orifice configuration with a small, rudimentary left-sided mitral valve and a large, dominant, right-sided parachute mitral valve with Barlow-type of degeneration. The patient underwent reconstruction of both valves through a minimally invasive incision. At one year echocardiographic control both valves function normally.
It is now accepted that heart failure (HF) is a complex multifunctional disease rather than simply a hemodynamic dysfunction. Despite its complexity, stressed cardiomyocytes often follow conserved patterns of structural remodelling in order to adapt, survive, and regenerate. When cardiac adaptations cannot cope with mechanical, ischemic, and metabolic loads efficiently or become chronically activated, as, for example, after infection, then the ongoing structural remodelling and dedifferentiation often lead to compromised pump function and patient death. It is, therefore, of major importance to understand key events in the progression from a compensatory left ventricular (LV) systolic dysfunction to a decompensatory LV systolic dysfunction and HF. To achieve this, various animal models in combination with an “omics” toolbox can be used. These approaches will ultimately lead to the identification of an arsenal of biomarkers and therapeutic targets which have the potential to shape the medicine of the future.
Background: Cerebral oxygen saturation (ScO2) can be measured non-invasively by near-infrared spectroscopy (NIRS) and correlates with cerebral perfusion. We investigated cerebral saturation during transfemoral transcatheter aortic valve implantation (TAVI) and its impact on outcome.
Methods and results: Cerebral oxygenation was measured continuously by NIRS in 173 analgo-sedated patients during transfemoral TAVI (female 47%, mean age 81 years) with self-expanding (39%) and balloon-expanding valves (61%). We investigated the periprocedural dynamics of cerebral oxygenation. Mean ScO2 at baseline without oxygen supply was 60%. During rapid ventricular pacing, ScO2 dropped significantly (before 64% vs. after 55%, p < 0.001). ScO2 at baseline correlated positively with baseline left-ventricular ejection fraction (0.230, p < 0.006) and hemoglobin (0.327, p < 0.001), and inversely with EuroSCORE-II ( − 0.285, p < 0.001) and length of in-hospital stay ( − 0.229, p < 0.01). Patients with ScO2 < 56% despite oxygen supply at baseline had impaired 1 year survival (log-rank test p < 0.01) and prolonged in-hospital stay (p = 0.03). Furthermore, baseline ScO2 was found to be a predictor for 1 year survival independent of age and sex (multivariable adjusted Cox regression, p = 0.020, hazard ratio (HR 0.94, 95% CI 0.90–0.99) and independent of overall perioperative risk estimated by EuroSCORE-II and hemoglobin (p = 0.03, HR 0.95, 95% CI 0.91–0.99).
Conclusions: Low baseline ScO2 not responding to oxygen supply might act as a surrogate for impaired cardiopulmonary function and is associated with worse 1 year survival and prolonged in-hospital stay after transfemoral TAVI. ScO2 monitoring is an easy to implement diagnostic tool to screen patients at risk with a potential preserved recovery and worse outcome after TAVI.
Background: Cerebral O2 saturation (ScO2) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). Objectives: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. Methods and Results: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. Conclusions: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.
Background: Point of care devices for performing targeted coagulation substitution in patients who are bleeding have become increasingly important in recent years. New on the market is the Quantra. It is a device that uses sonorheometry, a sonic estimation of elasticity via resonance, which is a novel ultrasound-based technology that measures viscoelastic properties of whole blood. Several studies have already shown the comparability of the Quantra with devices already established on the market, such as the rotational thromboelastometry (ROTEM) device.
Objective: In contrast to existing studies, this study is the first prospective interventional study using this new system in a cardiac surgical patient cohort. We will investigate the noninferiority between an already existing coagulation algorithm based on the ROTEM/Multiplate system and a new algorithm based on the Quantra system for the treatment of coagulopathic cardiac surgical patients.
Methods: The study is divided into two phases. In an initial observation phase, whole blood samples of 20 patients obtained at three defined time points (prior to surgery, after completion of cardiopulmonary bypass, and on arrival in the intensive care unit) will be analyzed using both the ROTEM/Multiplate and Quantra systems. The obtained threshold values will be used to develop a novel algorithm for hemotherapy. In a second intervention phase, the new algorithm will be tested for noninferiority against an algorithm used routinely for years in our department.
Results: The main objective of the examination is the cumulative loss of blood within 24 hours after surgery. Statistical calculations based on the literature and in-house data suggest that the new algorithm is not inferior if the difference in cumulative blood loss is <150 mL/24 hours.
Conclusions: Because of the comparability of the Quantra sonorheometry system with the ROTEM measurement methods, the existing hemotherapy treatment algorithm can be adapted to the Quantra device with proof of noninferiority.
Trial Registration: ClinicalTrials.gov NCT03902275; https://clinicaltrials.gov/ct2/show/NCT03902275
International Registered Report Identifier (IRRID): DERR1-10.2196/17206
Improved integration of single cell transcriptome data demonstrated on heart failure in mice and men
(2023)
Biomedical research frequently uses murine models to study disease mechanisms. However, the translation of these findings to human disease remains a significant challenge. In order to improve the comparability of mouse and human data, we present a cross-species integration pipeline for single-cell transcriptomic assays.
The pipeline merges expression matrices and assigns clear orthologous relationships. Starting from Ensembl ortholog assignments, we allocated 82% of mouse genes to unique orthologs by using additional publicly available resources such as Uniprot, and NCBI databases. For genes with multiple matches, we employed the Needleman-Wunsch global alignment based on either amino acid or nucleotide sequence to identify the ortholog with the highest degree of similarity.
The workflow was tested for its functionality and efficiency by integrating scRNA-seq datasets from heart failure patients with the corresponding mouse model. We were able to assign unique human orthologs to up to 80% of the mouse genes, utilizing the known 17,492 orthologous pairs. Curiously, the integration process enabled the identification of both common and unique regulatory pathways between species in heart failure.
In conclusion, our pipeline streamlines the integration process, enhances gene nomenclature alignment and simplifies the translation of mouse models to human disease. We have made the OrthoIntegrate R-package accessible on GitHub (https://github.com/MarianoRuzJurado/OrthoIntegrate), which includes the assignment of ortholog definitions for human and mouse, as well as the pipeline for integrating single cells.
Background. Transcatheter aortic valve implantation (TAVI) is currently recommended for patients with severe aortic stenosis at intermediate or high surgical risk. The decision process during TAVI evaluation includes a thorough benefit-risk assessment, and knowledge about long-term benefits and outcomes may improve patients’ expectation management. Objective. To evaluate patients’ perceived health status and self-reported long-term outcome more than 5 years after TAVI. Methods and Results. Demographic and procedure data were obtained from all patients treated with TAVI at our institution from 2006 to 2012. A cross-sectional survey was conducted on the patients alive, measuring health status, including the EQ-5D-5L questionnaire, and clinical outcomes. 103 patients (22.8%) were alive at a median follow-up period of 7 years (5.4–9.8). 99 (96%) of the 103 patients were included in the final analysis. The mean age at follow-up was 86.5 years ± 8.0 years, and 56.6% were female. Almost all patients (93.9%) described an improvement of their quality of life after receiving TAVI. At late follow-up, the mean utility index and EQ-VAS score were 0.80 ± 0.20 and 58.49 ± 11.49, respectively. Mobility was found to be the most frequently reported limitation (85.4%), while anxiety/depression was the least frequently reported limitation (19.8%). With respect to functional class, 64.7% were in New York Heart Association (NYHA) class III or IV, compared to 67.0% prior to TAVI (p = 0.51). Self-reported long-term outcomes revealed mainly low long-term complication rates. 74 total hospitalizations were reported after TAVI, and among those 43% for cardiovascular reasons. Within cardiovascular rehospitalizations, new pacemaker implantations were the most frequently reported (18.9%), followed by cardiac decompensation and coronary heart disease (15.6%). Conclusion. The majority of the patients described an improvement of health status after TAVI. More than five years after TAVI, the patients’ perceived health status was satisfactory, and the incidence of clinical events and hospitalizations was very low.
Background: The aim of this study was to evaluate the longer-term results of bicuspid aortic valve (BAV) repair with or without aortic root replacement. Methods: From 1999 to 2017, 142 patients with or without aortic root dilatation who underwent repair of a regurgitant BAV were included in the study. Ninety-four patients underwent isolated BAV repair (Group 1; median age 43 years) and 48 patients underwent valve-sparing aortic root replacement plus BAV repair (aortic valve reimplantation—Group 2; median age 48 years). Median clinical follow-up time was 5.9 years (range 0.5–15) in Group 1 and 3 years (range 0.5–16) in Group 2, respectively. Results: In-hospital mortality was 1% in Group 1, and 2% in Group 2 (p = .6). The 5- and 10-year survival was 93 ± 2.9% and 81 ± 5.8% in Group 1 and 96 ± 3.1% and 96 ± 3.1% in Group 2, respectively (p = .31). Eleven patients of Group 1 (1.7%/patient-year) and five patients of Group 2 (2.2%/patient-year) underwent reoperation of the aortic valve (p = .5). The 5- and 10-year freedom from reoperation were 93.0 ± 2.1% and 77.1 ± 7.1% in Group 1 and 93.0 ± 5.0% and 76.7 ± 9.6% in Group 2 (p = .83), respectively. At the latest follow-up, only two patients of Group 1 and 1 patient of Group 2 had AV regurgitation = 2° (p = .7). The cumulative linearized incidence of all valve-related complications (bleeding, stroke, endocarditis, and reoperation) was 2.9%/patient-year in Group 1% and 4%/patient-year in Group 2, respectively (p = .6). Conclusions: Isolated BAV repair and combined aortic valve reimplantation plus BAV repair provide good clinical longer-term outcomes with relatively low reoperation rate and durable valve function.
Aims: Patients with aortic stenosis (AS) may have concomitant heart failure (HF) that determines prognosis despite successful transcatheter aortic valve implantation (TAVI). We compared outcomes of TAVI patients with low stroke volume index (SVI) ≤35 ml/m2 body surface area in different HF classes.
Methods and results: Patients treated by transfemoral TAVI at our center (n = 1822) were classified as 1) ‘HF with preserved ejection fraction (EF)’ (HFpEF, EF ≥50%), 2) ‘HF with mid-range EF’ (HFmrEF, EF 40–49%), or 3) ‘HF with reduced EF’ (HFrEF, EF <40%). Patients with SVI >35 ml/m2 served as controls. The prevalence of cardiovascular disease and symptoms increased stepwise from controls (n = 968) to patients with HFpEF (n = 591), HFmrEF (n = 97), and HFrEF (n = 166). Mortality tended to be highest in HFrEF patients 30 days post-procedure, and it became significant after one year: 10.2% (controls), 13.5% (HFpEF), 13.4% (HFmrEF), and 23.5% (HFrEF). However, symptomatic improvement in survivors of all groups was achieved in the majority of patients without differences among groups.
Conclusions: Patients with AS and HF benefit from TAVI with respect to symptom alleviation. TAVI in patients with HFpEF and HFmrEF led to an identical, favorable post-procedural prognosis that was significantly better than that of patients with HFrEF, which remains a high-risk population.