Background: Rates of permanent pacemaker implantation (PPI) have been low using the self‐expanding ACURATE neo device, but data regarding risk factors of PPI for this specific device are scarce.
Methods: The study cohort consisted of patients (n = 1000) with severe aortic stenosis undergoing transfemoral transcatheter aortic valve implantation (TAVI) using the ACURATE neo prosthesis in our center between May 2012 and December 2019. For the present analysis, we excluded patients with previous permanent pacemaker (n = 110), high‐grade AV block prior to TAVI (n = 3), and patients requiring conversion to surgical valve replacement (n = 4) or the implantation of a second prosthesis as valve‐in‐valve (n = 15). Preexisting conduction abnormalities were determined, and the implantation depth of the prosthesis was measured on final angiography. Differences across quartiles based on the original consecutive cohort were analyzed with respect to implantation depth and PPI rate. Predictors of PPI were identified using logistic regression.
Results: The PPI rate was 10%. Preexisting AV block I°, right bundle branch block (RBBB), and the implantation depth were independent predictors of PPI. Across quartiles, the implantation depth differed significantly with lowest values in the last quartile, whereas differences of PPI rates across quartiles were not statistically significant, but showed a notable decrease in the last quartile.
Conclusion: Preexisting RBBB, AV block I°, and low implantation depth were independent predictors of PPI following TAVI using the ACURATE neo device. Instead of deliberately aiming at a high position, avoidance of a low implantation depth may represent a reasonable compromise to reduce the rate of PPI without increasing the risk of malpositioning.
Background: Balloon pulmonary angioplasty is an evolving, interventional treatment option for inoperable patients with chronic thromboembolic pulmonary hypertension (CTEPH). Pulmonary hypertension at rest as well as exercise capacity is considered to be relevant outcome parameters. The aim of the present study was to determine whether measurement of pulmonary hemodynamics during exercise before and six months after balloon pulmonary angioplasty have an added value.
Methods: From March 2014 to July 2018, 172 consecutive patients underwent balloon pulmonary angioplasty. Of these, 64 consecutive patients with inoperable CTEPH underwent a comprehensive diagnostic workup that included right heart catheterization at rest and during exercise before balloon pulmonary angioplasty treatments and six months after the last intervention.
Results: Improvements in pulmonary hemodynamics at rest and during exercise, in quality of life, and in exercise capacity were observed six months after balloon pulmonary angioplasty: WHO functional class improved in 78% of patients. The mean pulmonary arterial pressure (mPAP) at rest was reduced from 41 ± 9 to 31 ± 9 mmHg (p < 0.0001). The mPAP/cardiac output slope decreased after balloon pulmonary angioplasty (11.2 ± 25.6 WU to 7.7 ± 4.1 WU; p < 0.0001), and correlated with N-terminal fragment of pro-brain natriuretic peptide (p = 0.035) and 6-minute walking distance (p = 0.01).
Conclusions: Exercise right heart catheterization provides valuable information on the changes of pulmonary hemodynamics after balloon pulmonary angioplasty in inoperable CTEPH patients that are not obtainable by measuring resting hemodynamics.