Refine
Year of publication
Document Type
- Master's Thesis (61) (remove)
Has Fulltext
- yes (61)
Is part of the Bibliography
- no (61)
Keywords
- Beschleunigerphysik (2)
- Ionenstrahl (2)
- Strahldynamik (2)
- Toroidales Magnetfeld (2)
- (n (1)
- ALICE (1)
- Accelerator Physics (1)
- Beam Dynamic (1)
- Beryllium-7 (1)
- CBM (1)
Institute
- Physik (61) (remove)
The ALICE Time Projection Chamber (TPC) is the main tracking detector of ALICE which was designed to perform well at multiplicities of up to 20000 charged primary and secondary tracks emerging from Pb-Pb collisions. Successful operation of such a large and complex detector requires an elaborate calibration and commissioning. The main goal for the calibration procedures is to provide the information needed for the offline software for the reconstruction of the particle tracks with sufficient precision so that the design performance can be achieved. For a precise reconstruction of particle tracks in the TPC, the calibration of the drift velocity, which in conjunction with the drift time provides the z position of the traversing particles, is essential. In this thesis, an online method for the calibration of the drift velocity is presented. It uses the TPC Laser System which generates 336 straight tracks within the active volume of the TPC. A subset of these tracks, showing sufficiently small distortions, is used in the analysis. The resulting time dependent drift velocity correction parameters are entered into a database and provide start values for the offline reconstruction chain of ALICE. Even though no particle tracking information is used, the online drift velocity calibration is in agreement with the full offline calibration including tracking on the level of about 2 x 10 exp (-4). In chapter 2, a short overview of the ALICE detector, as well as the data taking model of the ALICE, is given. In chapter 3, the TPC detector is described in detail. Lastly in chapter 4, the online drift velocity calibration method is presented, together with a detailed description of the TPC laser system.
Nichtinvasive Detektoren für ortsaufgelöste Strahlprofilmessungen gewinnen mit zunehmenden Strahlströmen und -energien immer mehr an Bedeutung. An der Universität Frankfurt im Institut für Angewandte Physik (IAP) wird ein “Figure Eight”-förmiger magnetostatischer Speichering mit Stellarator-Konfiguration (F8SR) entwickelt. Einige Aspekte der Strahldynamik in einem solchen Ring können mit einem experimentellen Aufbau am IAP untersucht werden. Die Herausforderung bei der Entwicklung eines Detektors an einem (F8SR) liegt auf der einen Seite darin den Strahl nichtinvasiv zu detektieren, und andererseits müssen magnetisch unempfindliche Komponenten für den Detektor ausgewählt werden. Dabei sollte der Detektor so flexibel sein, dass der Strahl entlang der Flugbahn transversal gemessen werden kann. In dieser Arbeit geht es um einen Detektor mit radial um den Strahl angeordneten Photodioden, mit deren Hilfe die strahlinduzierte Fluoreszenz detektiert wird und mit einem geeigneten Rekonstruktionsverfahren, Strahlposition und den Strahldurchmesser ermittelt werden kann. Die Messungen werden mit einem weiteren schon erprobten Detektor - einem Szintillationsschirm verglichen.
Da in der Run 3 Periode des CERN LHC die Kollisionsrate auf 50 kHz erhöht werden soll, muss die ALICE TPC umgebaut werden. Die Vieldrahtproportionalkammern mit Sperrgitter sollen gegen eine GEM-basierte Auslese ausgetauscht werden, um eine kontinuierliche Auslese zu ermöglichen.
Es wurde eine GEM-Testkammer, die mit drei und vier GEM-Folien betrieben werden kann, entwickelt und gebaut. GEM-Folien wurden unter dem Mikroskop auf Fehler untersucht und auf ihre Spannungsfestigkeit hin getestet sowie gerahmt und in die Kammer eingesetzt. Mit der fertigen kleinen TPC mit GEM-basierter Auslese wurden IBF und Energieauflösung gemessen. Ziel der Messungen war es, einen möglichst geringen IBF von unter 1 % zu erhalten, um so wenig wie möglich Feldverzerrungen im Driftvolumen der TPC zu erhalten, bei gleichzeitig guter Energieauflösung von mindestens 12 %, um eine gute Teilchenidentifikation in der TPC sicherzustellen.
Da standard GEM-Konfigurationen mit nur drei GEM-Folien zwar eine gute Energieauflösung, jedoch zu viel IBF aufweisen, wurden die Messungen hauptsächlich mit vier GEM-Folien durchgeführt. Es wurden zwei verschiedene Arten von GEM-Folien verwendet, Standard (S) und Large-Pitch (LP) GEM-Folien, die bei einem Großteil der Messungen in der S-LP-LP-S-Konfiguration angeordnet waren.
Es wurde festgestellt, dass sich IBF und Energieauflösung gegenläufig verhalten, bei besser werdendem IBF also die Energieauflösung schlechter wird und umgekehrt.
Es wurden zwei verschiedene Gasmischungen, Ne-CO2-N2 (90-10-5) und Ar-CO2 (90-10), untersucht. Mit Neon wurde bei einem Gain von 2000 gemessen, mit Argon nur bei einem Gain von 1000, da bei Argon die Anzahl der produzierten Elektronen pro cm etwa doppelt so groß ist.
Der IBF war mit beiden Gasmischungen etwa gleich groß. Die Energieauflösung war mit Argon jedoch aufgrund des niedrigeren Gains erheblich schlechter. Mit Ne-CO2-N2 (90-10-5) gelang es, einen Arbeitspunkt mit einer Energieauflösung von etwa 12 % und einem IBF von unter 1 % zu finden, mit Ar-CO2 (90-10) war dies jedoch nicht der Fall.
Das Ziel dieser Masterarbeit ist die Auslegung des Kickers für den Bunch-Kompressor des FRANZ-Projektes. Anhand eines Modells wurden die verschiedenen Möglichkeiten der Einkopplung sowie das Feld zwischen den Kondensatorplatten bereits untersucht. In der vorliegenden Arbeit wird der Kicker mit Hilfe des Programms CST Microwave Studio erstellt und optimiert, sodass er nach Abschluss der Untersuchungen in die Fertigung gehen kann. Dabei ist der erste Schwerpunkt der Untersuchungen die Auslegung und Optimierung der Kondensatorplatten, die für die Auslenkung der Mikro-Bunche im FRANZ-Projekt verantwortlich sind. Zu Beginn der Masterarbeit gab es gezielte Winkelverteilungen, die der Kicker im Rahmen des FRANZ-Projektes erreichen sollte. Nachdem ein Erreichen dieser Werte nur bedingt möglich war, wurden verschiedene Abschnitte des FRANZ-Projektes neu überdacht und die Anforderungen an den Kicker änderten sich dadurch grundlegend. Aus diesem Grund wurde der Kicker zu Beginn der Arbeit für eine Frequenz von 5 MHz ausgelegt, wohingegen er im Rahmen der neuen Anforderungen für eine Resonanzfrequenz von 2,57 MHz ausgelegt wurde. Die Untersuchung der optimalen Resonanzfrequenz für die Anforderungen des Kickers stellt den zweiten Schwerpunkt dieser Arbeit dar.
The aim of this thesis is finding a geometric configuration that allows electron insertion into a Gabor plasma lens in order to increase the density of the confined electrons and provide ignition conditions at parameters where ignition is not possible. First, simulations using CST and bender were conducted to investigate several geometric configurations in terms of their performance of inserting electrons manually. One particular design has been chosen as a basis for an experiment. In order to prepare the experiment, further simulations using the code bender have been conducted to investigate the density distribution that is formed inside the Gabor lens when inserting electrons transversally in compliance with the chosen design. Additionally, bender was used to investigate the impact of the initial electron energy on the distribution inside the lens. Simulations with and without space charge effects have shown a significant impact of the space charge effects on the resulting density dstribution. Therefore, space charge effects have proven to be the major electron redistribution process. A given electron source was characterised in order to find the performance under the conditions inside a Gabor lens. In particular, a transversal magnetic field that will be present in the experiment has to be compensated by shielding the inner regions of the source by a μ-metal layer. Using a μ-metal shield, transversal magnetic fields are sufficiently tolerable to perform measurements in a Gabor lens. Additionally, operating close to 100 eV electron energy yields a maximum in the emitted current. Adding a Wehnelt cylinder to the electron source furthermore improves the extracted current to roughly 1 mA. A test stand consisting of a newly designed anode for the Gabor lens, as well as a terminal for the electron source, was constructed. The electron source was thoroughly characterised in the environment of the Gabor lens and the ignition properties of the new system were evaluated. In further experiments, electron beam assisted ignition by increasing the residual gas pressure was observed and the impact of the position of the electron source on the ignition properties was investigated. In addition, ignition of a sub-critical state, that is a state consisting of potential, magnetic field and pressure that did not yet perform ignition by itself, was performed by increasing the extracted current from the electron source. Finally, the electron source was used to influence a pre-ignited plasma. The density was measured, which was increased by the use of the electron source in most cases. This project is part of the EDEN collaboration (Electron DENsity boosting) of the NNP Group at IAP Frankfurt with INFN institutes in Bologna and Catania.
Electron identification with a likelihood method and measurements of di-electrons for the CBM-TRD
(2017)
In this work a likelihood method has been implemented and investigated as particle identification algorithm for the CBM-TRD.
The creation of the probability distributions for the likelihood method via V0-topologies seems to be feasible and the purity of the obtained samples is sufficient for the usage in the likelihood method.
The comparison between the ANN and the likelihood method shows no differences in the identification performance. The pion suppression factor reaches the same values for the same electron identification efficiencies and the yields of the resulting di-lepton signals are comparable. The signal-to-background ratios for both methods have the same values and show a value of about 10−2 in the invariant mass range of minv = 1.5 - 2.5 GeV/c2, which is expected to be sufficient to provide access to the thermal in-medium and QGP radiation.
The investigation of a detector system without a TRD shows no pion suppression for a momentum above p = 6 GeV/c. Therefore, the background contributions increase drastically and the signal-to-background ratio decreases at all invariant masses, but especially in the invariant mass range of minv = 1.5 - 2.5 GeV/c2.
The background contributions in the invariant mass range of minv = 1.5 - 2.5 GeV/c 2 are also influenced by the selected electron identification efficiency of the TRD, which significantly shifts the fraction of the eπ contributions relative to the total number of pairs.
Ziel der nuklearen Astrophysik ist es, die solare Häufigkeitsverteilung der Elemente zu erklären (siehe Seite 10, Abb. 1.1). Die Elemente bis zur Eisengruppe sind dabei unmittelbar nach dem Urknall und während verschiedener Brennphasen in Sternen durch Kernfusion entstanden. Da die Bindungsenergie pro Nukleon der Elemente in der Eisengruppe am höchsten ist, ist für den Aufbau schwererer Elemente keine Energiegewinnung durch Fusion geladener Teilchen mehr möglich und Neutroneneinfänge und Betazerfälle spielen die entscheidende Rolle für die Nukleosynthese. In Abhängigkeit von der Neutronendichte und der Temperatur wird dabei zwischen dem langsamen Neutroneneinfangprozess, dem s-Prozess, und dem schnellen Neutroneneinfangprozess, dem r-Prozess, unterschieden. Während der r-Prozess weit abseits der stabilen Isotope an der Neutronenabbruchkante statt findet, verläuft der Reaktionspfad des s-Prozesses entlang der stabilen Isotope am "Tal der Stabilität".
Cleaning an ion beam from unwanted fractions is crucial for intense ion beams. This thesis will explore separation methods using a collimation channel, electric and magnetic dipoles and a velocity selector for low intensity beams on an experimental basis. In addition, statistical data of degassing events during the commissioning of a pentode extraction system for beam energies from 20 - 120keV will be presented.