Refine
Year of publication
- 2004 (107) (remove)
Document Type
- Article (36)
- Preprint (31)
- Doctoral Thesis (22)
- diplomthesis (10)
- Part of Periodical (3)
- Conference Proceeding (2)
- Diploma Thesis (1)
- Review (1)
- Working Paper (1)
Has Fulltext
- yes (107)
Is part of the Bibliography
- no (107)
Keywords
- Relativistic heavy-ion collisions (2)
- Schwerionenphysik (2)
- Antiteilchen (1)
- Atom (1)
- Biomembran (1)
- Brownsche Bewegung (1)
- CERN (1)
- Carl Friedrich von Weizsäcker (1)
- Charge fluctuations (1)
- Chemical equilibration (1)
Institute
- Physik (107) (remove)
We discuss gapless colour superconductivity for neutral quark matter in β equilibrium at zero as well as at nonzero temperature. Basic properties of gapless superconductors are reviewed. The current progress and the remaining problems in the understanding of the phase diagram of strange quark matter are discussed.
We study the phase diagram of a generalized chiral SU(3)-flavor model in mean-field approxi- mation. In particular, the influence of the baryon resonances, and their couplings to the scalar and vector fields, on the characteristics of the chiral phase transition as a function of temperature and baryon-chemical potential is investigated. Present and future finite-density lattice calculations might constrain the couplings of the fields to the baryons. The results are compared to recent lattice QCD calculations and it is shown that it is non-trivial to obtain, simultaneously, stable cold nuclear matter.
Ziel der vorliegenden Arbeit ist die Entwicklung, Aufbau und Inbetriebnahme eines Funnelsystems zur Zusammenführung zweier Teilchenstrahlen, bestehend aus zwei Injektionssystemen, zwei RFQ-Beschleunigern, Hochfrequenz-Deflektoren und Diagnoseeinheiten. Die Aufgabe des Experiments ist die praktische Umsetzung eines neuartigen Verfahrens zur Strahlstromerhöhung bei im Idealfall gleichbleibender Emittanz und steigender Brillanz. Notwendig wird dies durch die benötigten hohen Strahlströme im niederenergetischen Bereich einiger zukünftiger geplanter Beschleunigeranlagen. Hier kann der Strahlstrom nicht mehr konventionell von einer einzigen Ionenquelle erzeugt werden. Nur durch die Parallelerzeugung mehrerer Teilchenstrahlen sowie mehrfachem Zusammenführen (Funneling) der Teilchenstrahlen ist es möglich, die notwendigen Strahlströme bei der geforderten kleinen Emittanz zur Verfügung zu stellen. Das Frankfurter Funneling-Experiment ist die skalierte erste HIDIF-Funneling-Stufe als Teil eines Fusionstreibers. Hier werden zwei möglichst identische Helium-Teilchenstrahlen von zwei Ionenquellen erzeugt und in zwei RFQ-Beschleunigern beschleunigt. Der Deflektor biegt die Teilchenstrahlen reißverschlussartig auf eine gemeinsame Strahlachse. Am Anfang der Arbeit stand die Optimierung des Betriebs der Beschleunigerkomponeten und die Entwicklung und der Aufbau eines Einzellendeflektors. Erste erfolgreiche Strahlexperimente zur Strahlvereinigung werden im Kapitel 7.5 vorgestellt. Die Phasenraumellipse des zusammengeführten Strahls zeigt starke bananenförmige Deformierungen, die auf eine schlechte Anpassung des RFQ an den Funnel-Deflektor zurückzuführen sind. Das Elektrodendesign des RFQ ist in zwei unabhängige Bereiche unterteilt. Die erste Zone dient der Beschleunigung der Teilchen. In der zweiten Zone soll erstmals ein sogenannter 3D-Fokus der Strahlradien der x- und y-Ebene und einer longitudinaler Fokussierung erreicht werden. Der zweite Abschnitt bestand für erste Strahltests aus zunächst unmodulierten Elektroden. Zur besseren Anpassung des RFQ an den Funneldeflektor wurde dann das letzte Elektrodenteil erneuert. Der Umbau erfolgte zunächst nur bei einem der beiden RFQ-Beschleuniger. Somit war der direkte Vergleich zwischen altem und neuen Elektrodendesign im Strahlbetrieb möglich. Mit diesem neuen Elektrodenendteil wurde eine Reduktion der Strahlradien der x- sowie y-Ebene, eine bessere longitudinalen Fokussierung sowie eine höhere Transmission erreicht (Kapitel 8). Damit ist es erstmals gelungen mit einer speziellen Auslegung der RFQ-Elektroden eine direkte Anpassung an nachfolgende Elemente zu realisieren. Untersuchungen zur Strahlzusammenführungen werden seit einigen Jahren am Institut durchgeführt. Mit der Entwicklung des 3D-matchers wurde ein weiteres der kritischen Probleme gelöst. Der Umbau des zweiten Beschleunigers findet zur Zeit statt. Nach der Inbetriebnahme werden Funneling-Experimente mit dem Einspalt- und einem neuem Vielspaltdeflektor folgen.
Es wurde eine Meßstation zum Vermessen von THz-Photomischern vorgestellt und aufgebaut. Weiterhin konnte gezeigt werden, wie diese Station es ermöglicht, das Vermessen von THz-Photomischern, im Vergleich zum bisher verwendeten Meßaufbau, deutlich zu vereinfachen und zu beschleunigen. Mit dieser Station wurden zwei Proben, die sich in der Dicke der LT-GaAs-Schicht unterscheiden, vermessen. Um die gemessenen Daten analysieren zu können wurden zuvor beschrieben, wie eine Modulation des Photostroms in Photomischern erhalten und damit THz-Strahlung erzeugt werden kann. Gemessen wurde die THz-Leistung in Abhängigkeit von Frequenz , Vorspannung und Leistung der optischen Beleuchtung. Diese Messungen haben zu Ergebnissen geführt, die nur zum Teil mit den theoretisch vorhergesagten Ergebnissen übereinstimmen. So wurde festgestellt, daß nur etwa 1 bis 2 % der theoretisch erwarteten THz-Leistung detektiert wurde. Dies kann an langlebigen Ladungsträgern liegen, die im Substrat erzeugt werden. Diese Ladungsträger unterhalb der LT-GaAs-Schicht führen zu einer erhöhten Leitfähigkeit und können dadurch Reflexion und Absorption von THz-Strahlung verursachen. Diese Vermutung wird unterstützt durch die Beobachtung einer starken Reduktion des Signals in einem gepulsten THz-System, wenn eine konstante Hintergrundbeleuchtung eingeschaltet wird.[45] Weiterhin ist nicht auszuschließen, daß die für die THz-Erzeugung relevante Lebenszeit der Ladungsträger deutlich größer ist, als die mit Anrege-Abfrage-Messungen bestimmte. Analog könnte auch eine deutlich höhere Kapazität des Photomischers als die theoretisch berechnete diese Beobachtung erklären. Ob langlebige Ladungsträger im Substrat für die geringe gemessen Leistung verantwortlich sind kann überprüft werden, indem zwischen Substrat und LT-GaAs-Schicht einen Bragg-Refelektor gewachsen wird. So kann verhindert werden, daß eingestrahlte Leistung das Substrat erreicht. Dadurch können keine Ladungsträger im Substrat angeregt werden. Zusätzlich hat dies den Effekt, daß ein größerer Anteil der eingestrahlten Strahlung absorbiert werden kann, weil die einfallende Strahlung wegen der Reflexion zweimal durch die LT-GaAs-Schicht läuft. Ein solcher Mischer wurde bereits von E. R. Brown vorgeschlagen.[46] Bei den Messungen der THz-Leistung gegen Vorspannung konnte beobachtet werden, daß der Photostrom eine andere Abhängigkeit von der Vorspannung zeigt, als theoretisch vorhergesagt wurde. Erwartet wurde ein linearer Zusammenhang. Bei höheren Vorspannungen wurde aber ein stärkerer Anstieg beobachtet. Dies kann z.B. an einem zusätzlichen nichtlinearen Strom durch das Substrat oder an einer vom elektrischen Feld abhängigen Lebenszeit der Ladungsträger liegen. Für beide Erklärungsansätze wurden vereinfachte Modelle vorgestellt. Beide Modelle treffen dabei unterschiedliche Vorhersagen über die Änderung der Effizienz beim Auftreten des höheren Stromes. Deutlich werden die Unterschiede in den Vorhersagen im Frequenzverlauf. So führt ein zusätzlicher Strom durch das Substrat zu einer Verringerung der Effizienz um einen von der Frequenz unabhängigen konstanten Faktor. Der Frequenzverlauf verschiebt sich also zu geringeren Effizienzen. Eine Erhöhung der Lebenszeit hingegen führt zu einem geänderten Frequenzverlauf. So ist die Änderung der Effiienz bei niedirgen Frequenzen gering, zu höheren Frequenzen hin ändert sich die Effizienz jedoch immer stärker. Die Vorhersagen beider Modelle wurden mit dem gemessenen Daten verglichen. Bei den gegebenen Parametern war der Unterschied zwischen den beiden Modellen jedoch zu gering und die Fluktuation in den Meßdaten zu hoch, um entscheiden zu können, welches der beiden Modelle die gemessenen Daten besser beschreibt. Um erkennen zu können, welches der Modelle den Effekt beschreibt, der zu einem höheren Strom führt, müßte der Effekt in den Meßdaten erhöht werden. Dies kann geschehen, indem zusätzlich bei höheren Spannungen gemessen wird. Es müßte dabei allerdings die optische Leistung reduziert werden, um ein Zerstören der Mischer zu vermeiden. In dieser Arbeit konnte somit gezeigt werden, daß die aufgebaute Meßstation ein vereinfachtes Messen von THz-Photomischern ermöglicht. Weiterhin konnte das Verhalten von zwei vermessenen Mischern gezeigt und analysiert werden, sowie weitere Messungen vorgeschlagen werden, die eine exaktere Analyse der Photomischer ermöglichen sollten.
Das im Rahmen dieser Arbeit durchgeführte Experiment hatte zum Ziel Interferenzeffekte beim dissoziativen Ladungstransfer bei Molekülion-Atomstößen zu beobachten. Interferenzeffekte in Molekül-Atomstößen wurden von McGuire hervorgesagt und berechnet [4]. Diese Arbeit betrachtet ein ähnlichen Reaktionssystem. Die von ihm vorausgesagten Effekte wurden bestätigt. Das Experiment hat es ermöglicht, Interferenzen für alle Molekülorientierungen zu betrachten, womit man leicht Analogien zu zwei speziellen Fällen herstellen kann: mit der Molekülachse senkrecht zur Strahlrichtung entsteht eine Situation ähnlich einem Doppelspalt, bei dem die Kerne des Moleküls als Reaktionszentrum an Stelle der Spalte treten; mit der Molekülachse in Strahlrichtung entsteht eine Situation bei der Streuung an einem einzelnen Atom. In allem Molekülorientierungen erkennt man ein ringförmiges Minimum bei 1.6 a.u., wie es insbesondere bei der Beugung einem einzelnen Atom zu beobachten ist. Bei senkrechter Stellung der Molekülachse zur z-Achse überlagert durch die Streifen eines Doppelspaltes. Es war außerdem möglich den Endzustand der Teilchen zu bestimmen, so daß man sagen konnte, ob eine Teilchen angeregt aus der Reaktion hervorgegangen ist oder ob es über metastabile Zwischenzustände zerfallen ist. So ließ sich für den Impulsübertrag von 1.6 au eine Besonderheit feststellen: ein Minimum läßt sich nur im direkten Kanal ohne Anregung beobachten. Findet der Zerfall hingegen über metastabile Zwischenzustände ohne Anregung statt, so weist dieser Kanal bei etwa 1.6 au ein Maximum auf. Parallel zur Durchführung dieser Arbeit wurden erste Tests mit einem digitalen Oszillographen von Aquiris gemacht. Dieser speichert den Spannungsverlauf der Spannung an den Delaylineanoden. Peaks müssen dann schnell genug erkannt und ausgewertet werden. In der Offlineanalyse wären dann eng nebeneinander oder übereinanderliegende Peaks besser als solche zu erkennen. Diese würde die Totzeitproblematik, die sie durch die Dissoziation eines Moleküls senkrecht zur z-Achse entsteht, erheblich entschärfen.
Die vorliegende Arbeit beschäftigt sich mit der Messung der Elektronen-Driftgeschwindigkeit in dem Gasgemisch Ne/CO2 (90% / 10 %). Durchgeführt wurde sie zur Optimierung der Spurendriftkammer des ALICE-Projektes am CERN. Mit dem Aufbau zur Driftgeschwindigkeitsmessung läßt sich eine Genauigkeit von 1‰ erzielen. Untersucht wurden mit diesem Anspruch die Abhängigkeiten von der Temperatur, von CO2 Konzentrationsänderungen sowie von Stickstoffzugabe. Für die genaue Messung der Driftgeschwindigkeit wurde eine kleine Driftkammer gebaut. Die Ionisation des Gases erfolgt mit Hilfe eines UV-Lasers, dessen Strahl zunächst aufgeweitet, und dann geteilt wird. Der Abstand der so erhaltenen zwei Laser-Strahlen wird mit Hilfe von zwei präzisen Doppelblenden definiert. Zur Kontrolle der Gaszusammensetzung und -qualität wurde eine Gasanalysestation zusammengestellt. Die aufgenommenen Daten werden über ein ADC-System auf einem Computer gespeichert. Damit können in der Analyse die Driftgeschwindigkeitsdaten mit den Gasdaten zeitgleich ausgewertet werden. Das wird u.a. für die Korrektur der Daten auf den momentanen Druck und die Temperatur des Gases benötigt. Die Driftgeschwindigkeit wurde bei Feldstärken von 100 - 900 V/cm in Schritten von 100 V/cm gemessen. Die Spurendriftkammer des ALICE-Experimentes soll bei einer Feldstärke von 400 V/cm arbeiten. Die dafür gemessenen Ergebnisse sind: Temperaturabhängigkeit: Bei der erreichbaren Genauigkeit läßt sich über die Abhängigkeit der Driftgeschwindigkeit ve􀀀 von der Teilchenzahldichte N des Gases ve􀀀 = f(E/N) = f(E*T/P) keine weitere Temperaturabhängigkeit feststellen. Die relative Änderung der Driftgeschwindigkeit mit der Temperatur beträgt: Dv400 e􀀀 DT = 3.1 +- 0.23‰ /K CO2-Abhängigkeit: Die relative Änderung der Driftgeschwindigkeit mit dem CO2-Gehalt bei einer CO2- Konzentration um die 10% beträgt: Dv400 e􀀀;CO2 = -7.69 +- 0.39 Eine Erhöhung des CO2-Gehaltes um 1‰ (10.0% -> 10.1 %) führt also zu einer Herabsetzung der Driftgeschwindigkeit um ca. 7.7‰. N2-Abhängigkeit: Die relative Änderung der Driftgeschwindigkeit bei Stickstoffzugabe beträgt Dv400 e􀀀;N2 = - 1.14 +- 0.08 Eine Zugabe von 1‰ N2 zur Driftgasmischung führt damit zu einer Herabsetzung der Driftgeschwindigkeit um ca. 1.1‰ .
A small electrostatic storage ring is the central machine of the Frankfurt Ion Storage Experiments (FIRE) which will be built at the new Stern-Gerlach Center of Frankfurt University. As a true multiuser, multipurpose facility with ion energies up to 50 keV, it will allow new methods to analyze complex many-particle systems from atoms to very large biomolecules. With envisaged storage times of some seconds and beam emittances in the order of a few mm mrad, measurements with up to 6 orders of magnitude better resolutions as compared to single-pass experiments become possible. In comparison to earlier designs, the ring lattice was modified in many details: Problems in earlier designs were related to, e.g., the detection of light particles and highly charged ions with different charge states. Therefore, the deflectors were redesigned completely, allowing a more flexible positioning of the diagnostics. Here, after an introduction to the concept of electrostatic machines, an overview of the planned FIRE is given and the ring lattice and elements are described in detail.
Im Rahmen dieser Arbeit wird ein Experiment vorgestellt, mit dem es möglich ist, die Wechselwirkungen zwischen Elektronen in der Gegenwart eines extrem starken Laserfeldes zu untersuchen. Diese resultieren aus der nichtsequentiellen Multiphoton- Doppelionisation von Neon in einem starken elektrischen Feld, das durch einen Hochleistungslaser erzeugt wird. Mit Hilfe der COLTRIMS-Technologie ist es möglich die entstandenen Teilchen nachzuweisen und die Impulskomponenten zu bestimmen. Bei dieser Technologie handelt es sich um ein „Mikroskop“, das atomphysikalische Prozesse vollständig differntiell beobachtet. Die bei der Doppelionisation entstandenen Elektronen und das Rückstossion werden mittels eines schwachen elektrischen Feldes auf orts- und zeitaufgelöste Multichannelplate-Detektoren mit Delaylineauslese geleitet. Zusätzlich wird noch ein magnetisches Feld überlagert. Aus dem Auftreffort und der Flugzeit der Teilchen können die Impulse bestimmt werden. Es ist erstmals möglich die Impulskomponenten der drei Raumrichtungen für alle an der Ionisation beteiligten Teilchen mit hinreichend guter Auflösung zu bestimmen. Es können vollständige differentielle Winkelverteilungen erzielt werden. Damit gelingt es, ein kinematisch vollständiges Experiment zu realisieren. Die Elektronen werden bevorzugt in Richtung des Polarisationsvektors des Laserlichtes emittiert. Aufgrund der guten Impulsauflösung ist es jetzt möglich, die Richtung senkrecht zur Polarisation zu untersuchen und die Erkenntnisse in Bezug zueinander zu bringen. Das der nichtsequentiellen Doppelionisation zu grunde liegende sehr anschauliche Modell ist der „Rescattering-Prozess“: Das Laserfeld koppelt an das Coulombpotential des Atoms und verformt es derart, dass ein Elektron die effektive Potentialbarriere überqueren oder durch diese durchtunneln kann. Dieses zuerst befreite Elektron wird durch das oszillierende elektromagnetische Feld zunächst vom Ursprungsion fortgetrieben. Kehrt aber die Phase des Laserfeldes um, wird es zurück zum Ion beschleunigt, nimmt dabei Energie aus dem Feld auf und kann durch Elektron-Elektron-Stossionisation ein zweites Elektron aus dem Atom ionisieren oder es können kurzzeitige Anregungszustände erzeugt werden, die später feldionisiert werden. Dieses Modell wurde schon durch ein Vielzahl von Experimenten verifiziert. Gleichzeitig wirft es aber auch Fragen auf: Wie sind die Elektron-Elektron-Korrelationen zu erklären? Wie hängt der Longitudinal- mit dem Transversalimpuls zusammen? Welche Ionisationsmechanismen treten wann auf? Zusammenfassend kann man sagen, dass ein Experiment präsentiert wird, das zur Erfoschung von Korrelationseffekten bei Multiphoton-Ionisation beiträgt und sehr detaillierte Einblicke in die Welt der Laseratomphysik gewährt. Die Daten belegen eindeutig, dass eine Messung der korrelierten Impulse mehrerer Teilchen in einem Laserfeld eine Zeitmessung mit einer Auflösung weit unter einer Femtosekunde ermöglicht. Das beobachtete Ein- und Ausschalten der Elektronenabstossung, je nach der über die Longitudinal-Impulskorrelation gemessenen Verzögerungszeit, zeigt die Möglichkeit „Attosekunden Physik ohne Attosekunden-Pulse“ zu betreiben.
Durch Messen der vollständigen Impulsvektoren beider Coulomb-explodierender, einfachgeladener Fragmente eines doppelionisierten, diatomaren, homonuklearen Moleküls (H2, N2, O2) können verschiedene Ionisationsprozesse identifiziert werden. Bei der sogenannten COLd Target Recoil Ion Momentum Spectroskopy (COLTRIMS) wird ein überschall Gasjet mit ultrakurzen, hochintensiven Laserpulsen penetriert. Aus den gemessenen Fragmentimpulsen kann die freigesetzte kinetische Energie, sowie die ursprüngliche Lage der Molekülachse im Laborsystem berechnet werden, woraus winkelabhängige Explosionswahrscheinlichkeiten abgeleitet werden können, die unter bestimmten Bedingungen die orbitale Symmetrie der Moleküle wiederspiegeln. Unter Benutzung verschiedener Pulslängen des Lasers (35 fs und 8 fs) und Variation der Polarisation (linear, zirkular) koennen Ionisationsmechanismen wie rescattering oder sequentielle Ionisation identifiziert werden.
Die künstliche elektrische Stimulation bietet oftmals die einzige Möglichkeit, nicht vorhandene bzw. verloren gegangene motorische sowie sensorische Aktivitäten in gewissem Umfang wieder herzustellen. Im Falle von tauben Patienten wird zur Erlangung von Hörempfindungen die elektrische Stimulation des peripheren auditorischen Systems mit Hilfe von Cochlea- oder Hirnstammimplantaten standardmäßig eingesetzt. Es ist dabei notwendig, natürliche neuronale Entladungsmuster durch die elektrisch evozierten Entladungsmuster nachzubilden. Bei einkanaligen Systemen kann nur die Zeitstruktur des Signals dargeboten werden. Mehrkanalige Systeme bieten hier noch zusätzlich die Möglichkeit auch örtlich selektiv bestimmte Nervenfasergruppen zu stimulieren und damit die Ortsstruktur in den Entladungsmustern zu repräsentieren. So hat es sich gezeigt, dass die Sprachverständlichkeit durch Verwendung von Mehrkanal-Elektroden verbessert werden kann. Grundvoraussetzung hierfür ist die Optimierung der Kanalseparation durch Kleinst-Vielkanalelektroden und der Wahl einer optimalen Codierstrategie des Signals.
Die Codierstrategie ist abhängig von dem jeweiligen spezifischen Einsatzbereich. So gaben z.B. schon Clopton und Spelman (1995) zu bedenken, dass die als selektiv berechnete tripolare (S3) Konfiguration nur für einen bestimmten Stimulationsstrombereich gültig ist. Hinzu kommt es bei simultaner Verwendung benachbarter Kanäle zu schmerzhaften Lautheitssummationen. Ursache hierfür sind einerseits die Überlagerung der durch die Elektroden stimulierten neuronalen Bereiche und andererseits die Wechselwirkungen von Strömen benachbarter Elektrodenkanäle. Diese Effekte führen nicht nur zu einer Verringerung der räumlichen Stimulationsauflösung, sondern auch zu einer Einschränkung der exakten Abbildung der Zeitstruktur innerhalb der einzelnen Stimulationskanäle.
Die Techniken und Grundlagen der elektrischen Stimulation von neuronalem Gewebe mit Kleinst-Vielkanalelektroden sind bisher kaum untersucht worden. Ziel dieser Arbeit war es, ein mathematisches Modell zu implementieren und Qualitätsparameter zu definieren, mit deren Hilfe die Verteilung des elektrischen Feldes und die daraus resultierende neuronale Erregung beschrieben und optimiert werden kann. Zur Verifizierung des Modells sollten Methoden und Techniken entwickelt werden, die eine hochauflösende Abtastung der elektrischen Felder und Messung der neuronalen Daten innerhalb eines Messsystems ermöglichen.
Bei der neuronalen Stimulation mit Kleinst-Vielkanalelektroden ergibt sich eine Reihe von Problemen grundsätzlicher Art. So werden bei elektrodenferner Stimulation größere Stimulationsströme benötigt als bei elektrodennaher Stimulation, wobei für den Strombedarf die Stimulationskonfiguration eine entscheidende Rolle spielt: Der S1 Stimulationsmodus benötigt weniger Strom zur Erreichung großer Stimulationstiefen als der S2 Stimulationsmodus. Der größte Strom wird mit zunehmendem Elektrodenabstand gleichermaßen von dem S3 und S7 Stimulationsmodus benötigt. Gleichzeitig verfügen Kleinst-Vielkanalelektroden bauartbedingt aber nur über kleine Elektrodenkontaktoberflächen und lassen daher auf Grund der kritischen Feldstärke nur geringe Stimulationsströme zu.
Ein weiteres Problem besteht bei diesen Kleinst-Elektrodendimensionen in der konkreten Lage der Neurone an denen eine neuronale Erregung evoziert wird. Die Dimension der Kleinst-Vielkanalelektroden liegt bei einem Elektrodenkanalkontaktdurchmesser von 70 µm bereits in der Größenordnung der zu stimulierenden Neurone mit einem Durchmesser von 10 bis 15 µm. Dies macht sich bei den Messungen besonders dann deutlich bemerkbar, wenn nicht der Stimulationsstrom die Größe des überschwelligen Bereichs modelliert, sondern wenn der Elektrodenkanalabstand durch die Wahl der entsprechenden Elektrodenkanäle verändert wird. Hier weisen zwar die meisten neuronalen Antworten noch in die sich aus dem Modell ergebende Richtung, jedoch kommt es zu einer höheren Streuung der Ergebnisse als bei Messungen mit der Folienelektrode, die eine Kontaktfläche von 170 µm besitzt.
Es gibt also eine Reihe von begrenzenden Faktoren bei der optimalen Dimensionierung der Stimulationselektrode, die sowohl abhängig von der physiologischen Topologie ist als auch von den eingesetzten Stimulationskonfigurationen. Es ist also zur Stimulation die Wahl der optimalen Codierstrategie und die richtige Dimensionierung der Stimulationselektrode sowie der Elektrodenkanalabstände von entscheidender Bedeutung.
Die neuronalen Messungen wurden erstmalig für diese Fragestellung am Hirnschnitt durchgeführt, da sie, im Gegensatz zu in-vivo Versuchen, eine exakte Positionierung der Elektroden auf dem Hirnschnitt unter Sichtkontrolle durch das Mikroskop erlauben. Es wurden aus den neuronalen Messungen die Amplituden und Latenzen der exzitatorischen postsynaptischen Potenziale (EPSP) sowie der Feldpotenziale ausgewertet.
Der Versuchsaufbau macht es möglich, die Potenzialfelder mit genau den Konfigurationen abzutasten, mit denen auch die neuronalen Messungen des Hirnschnittes durchgeführt wurden. Das implementierte Programm zur Berechnung der Feldverteilung besitzt zum Messprogramm ein Interface, so dass es möglich ist, die Einstellungen des Experimentes, wie Stimulationskonfigurationen, Abtastraster des Feldes und die Koordinaten des Messraums, in der Modellrechnung zu verwenden. Somit ist ein direktes Vergleichen zwischen Messung und Berechnung möglich. In nachfolgenden Arbeiten können die vorliegenden Ergebnisse als Grundlage für in-vivo Versuche eingesetzt werden.
Zur Durchführung der Messungen wurden sehr kleine Elektroden aus eigener Herstellung verwendet und es wurden uns freundlicherweise neu entwickelte Folienelektroden des Fraunhofer Instituts St. Ingbert zur Verfügung gestellt. Die Größe der verwendeten Kleinst-Vielkanalelektroden aus eigener Herstellung lag um ca. eine Zehnerpotenz unter den aktuell eingesetzten Elektrodentypen und ist speziell für den direkten Kontakt zwischen Elektrode und Gewebe konzipiert. Dies entspricht dem typischen Einsatzbereich von Hirnstammimplantaten. Dies ist auch notwendig, um eine maximale räumliche Separation der erzeugten Felder zu ermöglichen. Außerdem erlaubte das Elektrodendesign auf Grund der hohen Anzahl der Elektrodenkanäle und durch variieren der Konfigurationen die Feldrichtung zu bestimmen, ohne die Elektrode neu auf den Hirnschnitt aufsetzen zu müssen.
Der in dieser Arbeit implementierte Algorithmus zur Berechnung der Feldverteilungen und die eingeführten Qualitätsparameter erlauben, die unterschiedlichen Stimulationskonfigurationen miteinander zu vergleichen und zu optimieren. Die Ergebnisse aus diesen Modellrechnungen wurden sowohl mit den Messungen der elektrischen Felder als auch mit den Ergebnissen aus den neuronalen Antworten verglichen.
Der im Rahmen dieser Arbeit erstellte Versuchsaufbau bestand aus einer über mehrere Mikromanipulatoren getriebene mikrometergenaue Positioniereinrichtung. Es konnten sowohl die Stimulationselektrode als auch die Elektrode zur Aufzeichnung der neuronalen Daten gesteuert werden. Die Steuerung des gesamten Setup, d.h. die Positionierung, die Aufzeichnung der neuronalen Daten und die Generierung der Stimulationsmuster wurde über den zentralen Messrechner durch ein hierfür entwickeltes Computerprogramm gesteuert. Die Versuche wurden über ein inverses Mikroskop durch eine CCD-Kamera aufgezeichnet.
Der entscheidende Vorteil des in dieser Arbeit gewählten Modellansatzes besteht in der grundsätzlichen Beschreibung der Feldverteilung bei vielkanaliger Stimulation, so dass diese auch auf andere Elektrodenformen bzw. Konfigurationen und Dimensionen übertragbar ist. Es lassen sich so den verschiedenen Konfigurationen nach bestimmten Qualitätskriterien bewerten und an die jeweilige Zielrichtung der Stimulation anpassen. Die berechneten Felder konnten erfolgreich in der Messeinrichtung generiert und nachgemessen werden. Außerdem ist es gelungen, differenzierte neuronale Aktivitäten auszuwerten, welche die Aussagen des Modells abstützen.