Refine
Year of publication
- 2008 (64) (remove)
Document Type
- Doctoral Thesis (21)
- Article (17)
- diplomthesis (6)
- Conference Proceeding (5)
- Diploma Thesis (4)
- Bachelor Thesis (3)
- Book (3)
- Part of Periodical (2)
- Habilitation (1)
- Preprint (1)
Has Fulltext
- yes (64)
Is part of the Bibliography
- no (64)
Keywords
- LHC (3)
- Spektroskopie (3)
- ALICE <Teilchendetektor> (2)
- CERN (2)
- Datenanalyse (2)
- Elementarteilchen (2)
- Kernphysik (2)
- Quark-Gluon-Plasma (2)
- Schwerionenkollisionen (2)
- Schwerionenphysik (2)
Institute
- Physik (64) (remove)
Malignant neoplasms are one of the top causes of death in all developed countries around the world and account for almost one quarter of all deaths. An individual cell based computational model with strong connections to the experimental data through lattice free, newtonian interaction could be used to validate experimental results and eventually make predictions guiding further experiments. This model was build as a part of the thesis and shall be extended to the modelling of the effects of ionic radition on the vascularised tumour as a possible treatment for inoperable tumours.
Ein wesentlicher Forschungsgegenstand der Kernphysik ist die Untersuchung der Eigenschaften von Kernmaterie. Das Verständnis darüber gibt in Teilen Aufschluss über die Erscheinungsweise und Wechselwirkung von Materie. Ein Schlüssel liegt dabei in der Untersuchung der Modifikation der Eigenschaften von Hadronen in dem Medium Kernmaterie, das durch Parameter wie Dichte und Temperatur gekennzeichnet werden kann. Man hofft damit unter anderem Einblick in die Mechanismen zu bekommen, welche zur Massenbildung der Hadronen beitragen. Zur Untersuchung solcher Modifikationen eignen sich insbesondere Vektormesonen, die in e+e- Paare zerfallen. Die Leptonen dieser Paare wechselwirken nicht mehr stark mit der Materie innerhalb der Reaktionszone, und tragen somit wichtige Informationen ungestört nach außen. Das HADES-Spektrometer bei GSI wird dazu verwendet die leichten bei SIS-Energien produzierten Vektormesonen rho, omega und phi zu vermessen. Hierzu wurde zum erste mal das mittelschwere Stoßsystem Ar+KCl bei einer Strahlenergie von 1,76 AGeV gemessen. Die im Vergleich zum früher untersuchten System C+C höhere Spurmultiplizität innerhalb der Spektrometerakzeptanz verlangte eine Anpassung der bisher verwendeten Datenanalyse. Das bisher verwendete Verfahren, mehrere scharfe Schnitte auf verschiedene Observablen seriell anzuwenden, um einzelne Leptonspuren als solche zu identifizieren, wurde durch eine neu entwickelte multivariate Analyse ersetzt. Dabei werden die Informationen aller beteiligten Observablen mit Hilfe eines Algorithmus zeitgleich zusammengeführt, damit Elektronen und Positronen vom hadronischen Untergrund getrennt werden können. Durch Untersuchung mehrerer Klassifizierer konnte ein mehrschichtiges künstliches neuronalen Netz als am besten geeigneter Algorithmus identifiziert werden. Diese Art der Analyse hat den Vorteil, dass sie viel robuster gegenüber Fluktuationen in einzelnen Observablen ist, und sich somit die Effizienz bei gleicher Reinheit steigern lässt. Die Rekonstruktion von Teilchenspuren im HADES-Spektrometer basiert nur auf wenigen Ortsinformationen. Daher können einzelne vollständige Spuren a priori nicht als solche gleich erkannt werden. Vielmehr werden durch verschiedene Kombinationen innerhalb derselben Mannigfaltigkeit von Positionspunkten mehr Spuren zusammengesetzt, als ursprünglich produziert wurden. Zur Identifikation des maximalen Satzes eindeutiger Spuren eines Ereignisses wurde eine neue Methode der Spurselektion entwickelt. Während dieser Prozedur werden Informationen gewonnen, die im weiteren Verlauf der Analyse zur Detektion von Konversions- und pi0-Dalitz-Paaren genutzt werden, die einen großen Beitrag zum kombinatorischen Untergrund darstellen. Als Ergebnis wird das effizienzkorrigierte, und auf die mittlere Zahl der Pionen pro Ereignis normierte, Spektrum der invarianten Elektronpaarmasse präsentiert. Erste Vergleiche mit der konventionellen Analysemethode zeigen dabei eine um etwa 30% erhöhte Rekonstruktionseffizienz. Das Massenspektrum setzt sich aus mehr als 114.000 Paaren zusammen -- über 16.000 davon mit einer Masse größer als 150 MeV. Ein erster Vergleich mit einem einfachen thermischen Modell, welches durch den Ereignisgenerator Pluto dargestellt wird, eröffnet die Möglichkeit, die hier gefundenen Produktionsraten des omega- und phi-Mesons durch m_T-Skalierung an die durch andere Experimente ermittelten Raten des eta zu koppeln. In diesem Zusammenhang findet sich weiterhin ein von der Einschussenergie abhängiger Produktionsüberschluss von F(1,76) = Y_total/Y_PLUTO = 5,3 im Massenbereich M = 0,15...0,5 GeV/c^2. Die theoretische Erklärung dieses Überschusses birgt neue Erkenntnisse zu den in-Medium Eigenschaften von Hadronen.
The possible role of a first order QCD phase transition at nonvanishing quark chemical potential and temperature for cold neutron stars and for supernovae is delineated. For cold neutron stars, we use the NJL model with nonvanishing color superconducting pairing gaps, which describes the phase transition to the 2SC and the CFL quark matter phases at high baryon densities. We demonstrate that these two phase transitions can both be present in the core of neutron stars and that they lead to the appearance of a third family of solution for compact stars. In particular, a core of CFL quark matter can be present in stable compact star configurations when slightly adjusting the vacuum pressure to the onset of the chiral phase transition from the hadronic model to the NJL model. We show that a strong first order phase transition can have strong impact on the dynamics of core collapse supernovae. If the QCD phase transition sets in shortly after the first bounce, a second outgoing shock wave can be generated which leads to an explosion. The presence of the QCD phase transition can be read off from the neutrino and antineutrino signal of the supernova.
Die vorliegende Arbeit präsentiert den Aufbau und die Diagnostik eines Niederdruck-HF-Plasmas. Durchgeführt wurden die Messungen in einem Gasgemisch aus Ar/He (50%=50%). Sie dienten dazu, nähere Einblicke in die Plasmaparameter eines HF-Plasmas zu erhalten. Einen Schwerpunkt der vorliegenden Arbeit bildete dabei die Auswirkung unterschiedlicher Antennengeometrien auf die Entladungseigenschaften. Hierfür wurden die Plasmaparameter Elektronentemperatur Te, Elektronendichte ne und HF-Leistung in Abhängigkeit des Gasdruckes bei einer Vorwärtsleistung des HF-Generators von 1kW untersucht. Um eine sinnvolle Diagnostik zu gewährleisten, war es zunächst erforderlich eine induktive HF-Einspeisung zu konzipieren und eine Impedanzanpassung an dem vorhandenen 13,56MHz Generator vorzunehmen. Die Einspeisung der HF-Leistung geschieht über eine Spule, nach dem Transformatorprinzip. Der Aufbau bietet die Möglichkeit einer modularen Gestaltung der verwendeten Antennengeometrie. Hierdurch ist es möglich, sowohl die Länge, die Windungsbreite als auch die Windungsanzahl schnell zu ändern, um experimentell ein Optimum der Plasmaparameter bezüglich der Plasmaanregung zu erreichen.
Für die Bestimmung der Plasmaparameter wurde vorwiegend eine nicht invasive Diagnostiktechnik, die Emissionsspektroskopie, eingesetzt. Sie bietet den Vorteil, ein Plasma unberührt zu lassen und dessen Eigenschaften nicht zu verfälschen. Zusätzlich wurde mit einer Langmuirsonde die Elektronendichte gemessen. Die eingespeiste HF-Leistung wurde mit einem im HF-Generator befindlichen Reflektometer überwacht und dokumentiert. Durch systematisch durchgeführte Messungen konnte die Elektronentemperatur in Abhängigkeit des Gasdruckes für unterschiedliche Spulengeometrien mit Hilfe der Spektroskopie bestimmt werden. Es ergaben sich typische Elektronentemperaturen einer induktiven Entladung zwischen 1 eV und 5 eV. Die Ursache einer höheren Elektronentemperatur bei niedrigen Gasdrücken, unterhalb von 1 Pa, kann durch die stochastische Heizung sowie resonante Heizmechanismen erklärt werden.
Die mit der Langmuirsonde bestimmte Elektronendichte belief sich auf 4 x 10 exp 15 m exp -3 bei niedrigen Gasdrücken und einem Maximum von 4 x 10 exp 17 m exp -3 bei einem Gasdruck von 3 Pa. Elektronendichten dieser Größenordnung sind typisch für induktive Entladungsplasmen, die ein Maximum von 1019 m exp -3 [Lie05] erreichen können.
Die eingespeiste HF-Leistung zeigte dabei eine starke Abhängigkeit von der Antennengeometrie. Durch die Optimierung der Spulenkonfiguration ergab sich eine maximale eingespeisten HF-Leistung von 0,8kW.
Ein Vergleich von HF-Leistung und Elektronendichte bestätigte die theoretische Modellvorstellung, die einen linearen Zusammenhang zwischen diesen beiden Größen postuliert. Somit konnten wichtige Eigenschaften bezüglich einer HF-Entladung sowie Einflüsse der Antennengeometrie auf die Entladungseigenschaften untersucht und umfangreich diskutiert werden.
Die Coltrims-Methode hat sich seit den 1990er Jahren als gutes experimentelles Instrument in der Atomphysik und darüberhinaus etabliert. Sie beruht darauf, dass die bei einer Reaktion entstehenden Fragmente mit ortssensitiven Detektoren nachgewiesen werden. Die Signale der Detektoren wurden bisher mit einem analogen Vorverstärker verstärkt und dann mit Hilfe eines Constant Fraction Discriminators in digitale Signale umgewandelt. Die Zeitinformation der digitalen Signale wurden von Time to Digital Convertern aufgenommen und im Computer gespeichert. Mit dieser Form der Auslese und Analyse der von den Detektoren stammenden Signale können nur einige wenige Fragmente nachgewiesen werden. Die Lösung dieses Problems besteht also darin, eine neue Variante für die Auslese und Analyse der Signale zu finden. Diese wurde in der Verwendung eines Transientenrekorders gefunden. Anstatt nur die Zeitinformation zu speichern, nimmt dieser die gesamte Signalform der Detektoren auf. Die Aufgabe, die in dieser Arbeit bearbeitet werden sollte, bestand darin, eine Software zu entwickeln, mit deren Hilfe der Transientenrekorder gesteuert werden kann. Auch sollte ein Weg gefunden werden nur die für das Experiment notwendigen Informationen des aufgenommenen Zeitfensters zu speichern. Des Weiteren sollten Methoden aufgezeigt werden, wie die aufgenommen Signale untersucht und deren Parameter extrahiert werden können. Diese Methoden wurden dann an realen Signalen getestet. Nachdem im ersten Kapitel die Motivation zu dieser Arbeit und einige theoretische Hintergründe vorgestellt werden, wird im zweiten Kapitel auf verschiedene Methoden der Signalanalyse eingegangen. Der Augenmerk liegt dabei sowohl auf Einzel- sowie Doppelsignalanalyse. Die Güte der vorgestellten Algorithmen wird mit Hilfe von künstlichen Signalen ermittelt. Es zeigt sich, dass die beste Methode die zeitliche Position der Einzelsignale zu finden, der Pulsfit ist. Mit dieser Methode kann eine Auflösung von etwa 50 ps erzielt werden. Bei der Betrachtung der Doppelsignale stellt sich heraus, dass der minimale Abstand zwischen den Signalen 5 ns bis 7 ns betragen muss. Das dritte Kapitel zeigt eine Anwendung des neuen Aufnahmesystems. Dort werden die physikalischen Ergebnisse, die mit Hilfe des neuen Systems gewonnen werden konnten, mit einem herkömmlichen Aufnahmesystem verglichen. Aufgrund der geringeren Totzeit des neuen Aufnahmesystems konnte mehr Statistik gewonnen werden. Der dadurch gewonnene Vorteil zeigt sich deutlich in den Ergebnissen, bei denen eine vierfach Koinzidenz verlangt wird. Bei dem nächsten Kapitel beschriebenen Experiment mussten sehr viele Fragmente nachgewiesen werden. Hierzu wird ein weiteres Kriterium neben der Zeitsumme vorgestellt mit dem die Anodensignale einander zugewiesen werden können. Die in diesem Kapitel gezeigten physikalischen Ergebnisse zeigen die Impulsverteilungen für Neon und Helium für unterschiedliche Lichtintensitäten bzw. Ionisationsprozesse. Im darauf folgenden Kapitel wird beschrieben, wie die neue Aufnahmemethode dazu verwendet werden kann, die von den Detektoren kommenden Signale genauer zu analysieren. Die physikalische Reaktion führte dazu, dass von dem Detektor hauptsächlich Doppelsignale aufgenommen wurden. Dies erlaubt die Untersuchung der Doppelsignalalgorithmen an realen Signalen. Hierbei zeigte sich, dass die Totzeit bei realen Signalen vergleichbar mit der Totzeit bei künstlichen Signalen ist. Die Algorithmen können bei Abständen der Einzelsignale von weniger als 10 ns die Position der Signale nicht mehr genau bestimmen. Anhand der Pulshöhenverteilung kann gezeigt werden, dass der verwendete Detektor in der Mitte eine geringere Nachweiseffizienz hatte. Im letzten Kapitel wird die Güte der verschiedenen Methoden der Einzelsignalanalyse anhand von realen Signalen überprüft. Dabei wurden Signale desselben Detektors mit unterschiedlichen Vorverstärkern verstärkt. Die beiden Vorverstärker unterschieden sich in ihrer Bandbreitenbegrenzung. Die Daten wurden mit einem Transientenrekorder mit 2 GS aufgenommen. Es wird gezeigt wie diese Daten umgewandelt werden können, so dass sie einem System mit nur 1 GS entsprechen. Dies erlaubt es die Güte der Methoden für Signale eines Systems mit 2 GS mit denen eines Systems mit 1 GS zu vergleichen. Es zeigt sich in der Pulshöhenverteilung, dass die Signale des stärker bandbreitenbegrenzten Vorverstärkers vergleichbar mit den künstlichen Signalen sind. Die Signale des weniger stark bandbreitenbegrenzten Vorverstärkers weisen eine zu starke Abhängigkeit ihrer Breite von der Pulshöhe auf. Aus diesem Grund sind die Ergebnisse des letzt genannten Vorverstärkers abweichend von den Ergebnissen mit den künstlichen Signalen. Bei diesem Vorverstärker zeigte der einfache Constant Fraction Algorithmus die beste Auflösung.
Strong chromofields developed at early stages of relativistic heavy-ion collisions give rise to the collective deceleration of net baryons from colliding nuclei. We have solved classical equations of motion for baryonic slabs under the action of time-dependent chromofield. We have studied sensitivity of the slab trajectories and their final rapidities to the initial strength and decay pattern of the chromofield as well as to the back reaction of produced plasma. This mechanism can naturally explain significant baryon stopping observed at RHIC, an average rapidity loss hδyi ≈ 2. Using a Bjorken hydrodynamical model with particle producing source we also study the evolution of partonic plasma produced as the result of chromofield decay. Due to the delayed formation and expansion of plasma its maximum energy density is much lower than the initial energy density of the chromofield. It is shown that the net-baryon and produced parton distributions are strongly correlated in the rapidity space. The shape of net-baryon spectra in midrapidity region found in the BRAHMS experiment cannot be reproduced by only one value of chromofield energy density parameter ǫ0, even if one takes into account novel mechanisms as fluctuations of color charges generated on the slab surface, and weak interaction of baryon-rich matter with produced plasma. The further step to improve our results is to take into account rapidity dependence of saturation momentum as explained in thesis. Different values of parameter ǫ0 has been tried for different variants of chromofield decay to fit BRAHMS data for net-baryon rapidity distribution. In accordance with our analysis, data for fragmentation region correspond to the lower chromofield energy densities than mid-rapidity region. χ2 analysis favors power-law of chromofield decay with corresponding initial chromofield energy density of order ǫf = 30GeV/fm3.
Die HBT-Interferometrie bietet über die Analyse von Bose-Einstein-Korrelationen geladener Pionen die Möglichkeit, Raumzeit-Dimensionen von Kern-Kern-Reaktionen zu vermessen. Dadurch kann das Ausfrierverhalten der in diesen Reaktionen enstehenden teilchenemittierenden Quelle untersucht werden. Die so gewonnenen Informationen tragen zu einem Verständnis der in den Kollisionen ablaufenden Prozesse und somit zu Erkenntnissen über Kernmaterie unter extremen Bedingungen bei. Von besonderem Interesse ist dabei die Beobachtung der Ausbildung eines QGP-Zustandes. Hierfür sind systematische Studien von verschiedenen Kollisionssystemen und -energien von großer Bedeutung.
Im Rahmen dieser Arbeit wurde eine Analyse von Bose-Einstein-Korrelationen in Pb-Au-Kollisionen bei einer Strahlenergie von 80A GeV durchgeführt. Die hier analysierten Daten wurden mit dem CERES-Detektor am SPS-Beschleuniger des CERN aufgenommen. Diese Analyse stellt eine erneute Untersuchung des Datensatzes unter Verwendung einer verbesserten Kalibrierungsprozedur für den CERES-Detektor dar. Infolgedessen konnte eine Verringerung der systematischen Unsicherheiten erreicht werden. Die neuen Ergebnisse stimmen mit den von der CERES-Kollaboration bereits publizierten HBT-Ergebnissen zufriedenstellend überein. Der Vergleich mit den Ergebnissen des NA49-Experiments, dass Pb-Pb-Kollisionen bei gleicher Strahlenergie unter dem Aspekt der HBT-Interferometrie untersucht hat, zeigt ebenfalls eine Übereinstimmung.
Durch diese Konsistenz und die Minimierung der systematischen Unsicherheiten im Bereich der SPS-Energien wird nun die Interpretation des Ausfrierverhaltens der Quelle besser ermöglicht: In dieser Arbeit wurde eine universelle Ausfrierbedingung von Pionen bei unterschiedlichen Schwerpunktsenergien und für verschiedene Kollisionssysteme untersucht. Diesbezügliche Observablen sind das mittels HBT-Radien bestimmte Ausfriervolumen und die mittlere freie Weglänge von Pionen zum Zeitpunkt des Ausfrierens der Quelle.
Bei dieser Untersuchung in Abhängigkeit von der Schwerpunktsenergie der Kollision zeichnet sich ein Minimum des Ausfriervolumens bei hohen AGS- und niedrigen SPS-Energien ab. Zusätzlich ergibt sich für die mittlere freie Weglänge ein ebenfalls nicht monotones Verhalten in diesem Energiebereich. Aus der dort vergrößerten Weglänge lässt sich auf eine erhöhte Emissiondauer der teilchenemittierenden Quelle gegenüber anderen Energien schließen. Die Emissionsdauer spielt in Verbindung mit dem Nachweis eines QGP-Zustandes eine wichtige Rolle. Ob die beschriebenen Beobachtungen durch ein Ausbilden dieses Zustandes oder auf Grund von anderen unbekannten Mechanismen hervorgerufen werden, kann abschließend noch nicht beurteilt werden. Denn verbleibende systematischen Unsicherheiten bei niedrigen Schwerpunktsenergien lassen derzeit keine weiteren Interpretationen zu. Insbesondere betrifft dies die noch bestehende Diskrepanz der Ergebnisse zwischen CERES und NA49 für eine Strahlenergie von 40A GeV. Daher ist eine Reanalyse der Daten von CERES bei dieser Strahlenergie von Bedeutung. Ebenso würde eine erneute systematische Messung im AGS-Energiebereich weitere grundlegende Interpretationen ermöglichen.
In Zukunft werden am RHIC-Beschleuniger des BNL in den USA und im Rahmen des FAIR-Projektes an der GSI bei Darmstadt Experimente in dieser Energieregion durchgeführt werden. Möglicherweise kann dann anhand dieser Messung ein universelles Ausfrierkriterium für Pionen sowie der Grund für ein verändertes Systemverhalten bei bestimmten Energien festgestellt werden.
We explore the formation of diquark bound states and their Bose–Einstein condensation (BEC) in the phase diagram of three-flavor quark matter at nonzero temperature, T, and quark chemical potential, μ. Using a quark model with a four-fermion interaction, we identify diquark excitations as poles of the microscopically computed diquark propagator. The quark masses are obtained by solving a dynamical equation for the chiral condensate and are found to determine the stability of the diquark excitations. The stability of diquark excitations is investigated in the T–μ plane for different values of the diquark coupling strength. We find that diquark bound states appear at small quark chemical potentials and at intermediate coupling strengths. Bose–Einstein condensation of non-strange diquark states occurs when the attractive interaction between quarks is sufficiently strong.
We study the line shapes of radiative φ-decays with a direct coupling of the φ meson to the f0(980) and a0(980) scalar mesons. The latter couple via derivative interactions to π0π0 and π0η, respectively. Although the kaon-loop mechanism is usually regarded as the dominant mechanism in radiative φ decays, here we test a different possibility: we set the kaon-loop to zero and we fit the theoretical curves to the data by retaining only the direct coupling. Remarkably, satisfactory fits can be achieved, mainly due to the effects of derivative interactions of scalar with pseudoscalar mesons.
Motiviert durch aktuelle atomphysikalische Fragestellungen zur Struktur und Dynamik der Materie im Bereich hochgeladener Schwerionen entstand der Bedarf zur Weiterentwicklung bestehender und zur Entwicklung neuartiger ortsauflösender Detektorsysteme. Die Untersuchung der Struktur ist hauptsächlich durch die hochauflösende spektroskopische Vermessung einzelner Energieniveaus der atomaren Hülle bestimmt und liefert grundlegende Einblicke in den atomaren Aufbau. Dabei stellen diese Resultate gerade bei schweren hochgeladenen Ionen eine exzellente Testmöglichkeit der QED in extrem starken Feldern dar. Die Dynamik der Materie zeigt sich in der Teilchendynamik (hier der Atomhülle) in extrem starken und extrem kurzen elektromagnetischen Feldern, wie sie bei Ion-Atom-Stößen auftreten. Beobachtet werden können hier vor allem Teilchen und Photonen-Polarisationsphänomene. Solche Polarisationseffekte sind jedoch nicht auf das Gebiet der atomaren Hülle beschränkt. Als ein Beispiel sei die Untersuchung laserbeschleunigter Teilchen genannt. Hier kann die Polarimetrie von Röntgenstrahlung, die durch Thomson-Streuung optischer Photonen an den zuvor auf relativistische Geschwindigkeiten beschleunigten Teilchen erzeugt wird, Aufschluß über die Natur des Beschleunigungsprozesses geben. Einblick in die lineare Polarisation der Röntgenphotonen im für unsere Arbeit interessanten Energiebereich von einigen 10 keV bis einigen 100 keV können mit Compton-Polarimetern gewonnen werden. Kommerziell sind Detektorsysteme, die eine ausreichende Granularität in Kombination mit hinreichender Detektordicke besitzen, um hohe Nachweiseffizienzen zu erreichen, jedoch nicht verfügbar. Im Rahmen der vorgelegten Arbeit, die sich mit Techniken der hochaufgelösten Röntgenspektroskopie und der Röntgenpolarimetrie an hochgeladenen Schwerionen befasst, wurden vielfältige Arbeiten an und mit orts-, zeit- und energieauflösenden planaren Ge(i)-Detektorsystemen durchgeführt. Wesentliches Ziel der Arbeit war es, ein zweidimensional ortsauflösendes planares Halbleiterdetektorsystem, das für den Einsatz im Kristallspektrometer FOCAL und als Compton-Polarimeter angepasst ist, bereitzustellen. Hierzu wurde ein 2D-µ-Streifendetektorsystem aufgebaut, das eine Ortsauflösung von 250µm, bzw. 1167µm in orthogonaler Richtung, bei einer Detektordicke von 11mm und eine Energieauflösung von etwa 2 keV für jeden einzelnen Streifen bei 60 keV Photonenenergie gewährleistet. Durch Messungen an der Synchrotronquelle ESRF, Grenoble (Frankreich), wurde die Eignung des Systems als bildgebendes Element im FOCAL Kristallspektrometer bei einer Photonenenergie von 60 keV und als Compton-Polarimeter bei einer Photonenenergie von 210 keV untersucht. Der große Vorteil in FOCAL ein ortsauflösendes Detektorsystem einzusetzen, liegt darin, dass alle interessanten Beugungswinkel simultan beobachtet werden können. Im herkömmlichen Ansatz würde man mit einer einfachen Diode und einem Kollimator den Bereich abfahren. Wegen der geringen Ereignisrate und dem hohen Untergrund ist dies jedoch nicht praktikabel. Herkömmliche Systeme wie CCD oder Gasdetektoren haben nicht die nötige Effizienz oder eine zu hohe Dunkelrate. Zur Untersuchung der für FOCAL wichtigen Eigenschaften wurden mehrere Positionen auf dem Detektor bei niedriger Energie mit einem fein kollimierten Photonenstrahl (50 x 50 µm2) gescannt. Neben der guten Energieauflösung des Detektorsystems von durchschnittlich 2.2 keV bei 60 keV, zeigen die Ergebnisse das homogene Verhalten der Detektoreffizienz, welche essentiell für den spektographischen Einsatz in FOCAL ist. Es konnten keine Hinweise auf messbare Ladungsverluste im Bereich des aktiven Detektorvolumens festgestellt werden. Ebenso konnte die Multiplizität (Anzahl der Streifen einer Detektorseite, die auf ein Ereignis reagieren), mit der ein Photon nachgewiesen wird, eindeutig mit der Strukturierung der Kontakte auf der Kristalloberfläche in Verbindung gebracht werden. Es stellte sich heraus, dass die Ereignisse der Multiplizität zwei dazu verwendet werden können um Ortsauflösungen deutlich unterhalb einer Streifenbreite zu erreichen. Diese Methode kann jedoch nur auf eine größere Anzahl von Ereignissen angewendet werden, nicht jedoch auf einzelne Ereignisse. Um das 2D-Ge(i)-µ-Streifendetektorsystem auf seine Eignung als Compton-Polarimeter zu testen, wurden Daten mit einem nahezu vollständig linear polarisierten Photonenstrahl (98% linear polarisiert) bei einer Energie von 210 keV aufgenommen. Die Daten zeigen die erwartete Dipol-ähnliche Asymmetrie im Ortsbild und dienen als Kalibrationsgrundlage zur Interpretation zukünftiger Experimente zur Polarimetrie in diesem Energiebereich. Parallel hierzu wurde an Simulationsprogrammen auf Basis der etablierten Monte Carlo Software EGS4 gearbeitet. Hiermit wurden Vorhersagen bezüglich des Nachweisverhaltens des Detektors auf linear polarisierte Röntgenstahlung gemacht. Ferner wurde für ein 4x4-Pixel-Polarimeter, das bei der ersten Bestimmung der linearen Polarisation der K-REC Strahlung von U92+ am Speichering ESR der GSI eingesetzt wurde, im Rahmen der Datenanalyse mit den auf EGS4-basierenden Programmen die Detektoreffizienz für linear polarisierte Strahlung einer bestimmten Energie simuliert. Mit diesen Simulationsergebnissen konnten die selbstentwickelten Methoden zur Korrektur der Nachweiswahrscheinlichkeit eines Compton-Ereignisses als Funktion des Wechselwirkungspunkts innerhalb des Detektorkristalls und der Energie erfolgreich verifiziert werden. Die detektorbezogenen Resultate dieser Arbeit fanden ihre erste Anwendung in der FOCAL-Spektrometer Strahlzeit 2006, deren genaue Beschreibung jedoch über den Umfang dieser Arbeit hinausgeht. Ebenso flossen die Erfahrungen, die mit den Detektorsystemen, im speziellen dem 2D-Ge(i)-µ-Streifendetektor, gemacht wurden in die Realisierung eines Si(Li)-Detektors mit 32+32 Streifen zur Compton-Polarimetrie bei niedrigeren Energien (ab 60 keV) ein, der gegenwärtig in ersten Experimenten am ESR eingesetzt wird.