Filtern
Erscheinungsjahr
- 2010 (5) (entfernen)
Dokumenttyp
- Wissenschaftlicher Artikel (5) (entfernen)
Sprache
- Englisch (5) (entfernen)
Volltext vorhanden
- ja (5)
Gehört zur Bibliographie
- nein (5) (entfernen)
Institut
A new, two-channel instrument for simultaneous NO3 and N2O5 monitoring was used to make the first comprehensive set of nocturnal NOx measurements (NO, NO2, NO3 and N2O5) at the Taunus Observatory, a rural mountain site (Kleiner Feldberg) in South-western Germany. In May 2008, NO3 and N2O5 mixing ratios were well above the instrumental detection limit (a few ppt) on all nights of the campaign and were characterised by large variability resulting from inhomogeneously distributed sinks. The concentrations of NO3, N2O5 and NO2 were consistent with the equilibrium constant, K2, defining the rates of formation and thermal dissociation of N2O5. A steady-state lifetime analysis showed that nocturnal NOx losses were generally dominated by reaction of NO3 with volatile organic compounds in this forested region, with N2O5 uptake to aerosols of secondary importance. Analysis of a limited dataset obtained at high relative humidity indicated that the loss of N2O5 by reaction with water vapour is less efficient (> factor 3) than derived using laboratory kinetic data. The fraction of NOx present as NO3 and N2O5 reached ≈20% on some nights, with night-time losses of NOx competing with daytime losses.
A new, two-channel instrument for simultaneous NO3 and N2O5 monitoring was used to make the first comprehensive set of nocturnal NOx measurements (NO, NO2, NO3 and N2O5) at the Taunus Observatory, a rural mountain site (Kleiner Feldberg) in South-western Germany. In May 2008, NO3 and N2O5 mixing ratios were well above the instrumental detection limit (a few ppt) on all nights of the campaign and were characterised by large variability. The concentrations of NO3, N2O5 and NO2 were consistent with the equilibrium constant, K2, defining the rates of formation and thermal dissociation of N2O5. A steady-state lifetime analysis is consistent with the loss of nocturnal NOx being dominated by the reaction of NO3 with volatile organic compounds in this forested region, with N2O5 uptake to aerosols of secondary importance. Analysis of a limited dataset obtained at high relative humidity indicated that the loss of N2O5 by reaction with water vapour is less efficient (>factor 3) than derived using laboratory kinetic data. The fraction of NOx present as NO3 and N2O5 reached ~20% on some nights, with night-time losses of NOx competing with daytime losses.
Development of a Bioaerosol single particle detector (BIO IN) for the Fast Ice Nucleus CHamber FINCH
(2010)
In this work we present the setup and first tests of our new BIO IN detector. This detector was constructed to classify atmospheric ice nuclei (IN) for their biological content. It is designed to be coupled to the Fast Ice Nucleus CHamber FINCH. If one particle acts as an ice nucleus, it will be at least partly covered with ice at the end of the development section of the FINCH chamber. The device combines an auto-fluorescence detector and a circular depolarization detector for simultaneous detection of biological material and discrimination between water droplets, ice crystals and non activated large aerosol particles. The excitation of biological material with UV light and analysis of auto-fluorescence is a common principle used for flow cytometry, fluorescence microscopy, spectroscopy and imaging. The detection of auto-fluorescence of airborne single particles demands some more experimental effort. However, expensive commercial sensors are available for special purposes, e.g. size distribution measurements. But these sensors will not fit the specifications needed for the FINCH IN counter (e.g. high sample flow of up 10 LPM). The newly developed -low cost- BIO IN sensor uses a single high-power UV LED for the electronic excitation instead of much more expensive UV lasers. Other key advantages of the new sensor are the low weight, compact size, and the little effect on the aerosol sample, which allows it to be coupled with other instruments for further analysis. The instrument will be flown on one of the first missions of the new German research aircraft "HALO" (High Altitude and LOng range).
Surface measurements of aerosol and ice nuclei (IN) at a Central European mountain site during an episode of dust transport from the Sahara are presented. Ice nuclei were sampled by electrostatic precipitation on silicon wafers and were analyzed in an isothermal static vapor diffusion chamber. The transport of mineral dust is simulated by the Eulerian regional dust model DREAM. Ice nuclei and mineral dust are significantly correlated, in particular IN number concentration and aerosol surface area. The ice nucleating characteristics of the aerosol as analyzed with respect to temperature and supersaturation are similar during the dust episode than during the course of the year. This suggests that dust may be a main constituent of ice nucleating aerosols in Central Europe.
Surface measurements of aerosol and ice nuclei (IN) at a Central European mountain site during an episode of dust transport from the Sahara are presented. Transport is simulated by the Eulerian regional dust model DREAM. Ice nuclei and mineral dust are significantly correlated. The highest correlation is found between IN concentration and aerosol surface area. The ice nucleating characteristics of the aerosol with respect to temperature and supersaturation are similar during the dust episode than during the course of the year. This suggests that dust is always a dominant constituent of ice nucleating aerosols in Central Europe.