Refine
Year of publication
- 2011 (24) (remove)
Document Type
- Conference Proceeding (22)
- Article (2)
Language
- English (24)
Has Fulltext
- yes (24)
Is part of the Bibliography
- no (24)
Institute
- Physik (24)
As the successor of the EUROTRANS project, the MAX project is aiming to continue the R&D effects for a European Accelerator-Driven System and to bring the conceptual design to reality. The layout of the driver linac for MAX will follow the reference design made for the XT-ADS phase of the EUROTRANS project. For the injector part, new design strategies and approaches, e.g. half resonant frequency, half transition-energy between the RFQ and the CH-DTL, and using the 4-rod RFQ structure instead of the originally proposed 4-vane RFQ, have been conceived and studied to reach a more reliable CW operation at reduced costs. In this paper, the design and simulation results of the MAX injector are presented.
A test stand for optical beam tomography was developed. As a new non-destructive beam-diagnostic system for high current ion beams, the test stand will be installed in the low energy beam transport section (LEBT) of the Frankfurt Neutron Source (FRANZ) behind the chopper system. The test stand consists of a rotatable vacuum chamber with a mounted CCD camera. The maximum rotation angle amounts to 270°. In a first phase the optical beam profile measurement and 3D density reconstruction is tested with a time independent 10 keV He beam. The measurements and performance of data processing algorithms are compared with the beam transport simulations. In a later phase the performance with time dependent beams (120 keV, 200 mA) at a repetition rate of 250 kHz and a duty cycle of 2.5% has to be evaluated. An overview of the first phase results is shown.
The HITRAP linear decelerator currently being set up at GSI will provide slow, few keV/u highly charged ions for atomic physics experiments. The expected beam intensity is up to 105 ions per shot. To optimize phase and amplitude of the RF systems intensity, bunch length and kinetic energy of the particles need to be monitored. The bunch length that we need to fit is about 2 ns, which is typically measured by capacitive pickups. However, they do not work for the low beam intensities that we face. We investigated the bunch length with a fast CVD diamond detector working in single particle counting mode. Averaging over 8 shots yields a clear, regular picture of the bunched beam. Energy measurements by capacitive pickups are limited by the presence of intense primary and partially decelerated beam and hence make tuning of the IH-structure impossible. The energy of the decelerated fraction of the beam behind the first deceleration cavity was determined to about 10 % accuracy with a permanent dipole magnet combined with a MCP. Better detector calibration should help reaching the required 1%. Design of the detectors as well as the results of the measurements will be presented.
The development of a non- destructive measurement method for ion beam parameters has been treated in various projects. Although results are promising, the high complexity of beam dynamics has made it impossible to implement a real time process control up to now. In this paper we will propose analysing methods based on the dynamics of Cellular Nonlinear Networks (CNN) that can be implemented on pixel parallel CNN based architectures and yield satisfying results even at low resolutions.
Space charge lenses use a confined electron cloud for the focusing of ion beams. The focusing strength is given by the electron density whereas the density distribution influences the mapping quality of the space charge lens and is related to the confinement. The plasma parameters, loss as well as production mechanisms have a strong impact on plasma beam interactions. A scaled up space charge lens was constructed to investigate the properties of a nonneutral plasmas in detail. New non-interceptive diagnostic has been developed to characterize the collective behaviour of the confined nonneutral plasma in terms of an optimized lens design and parameters. Experimental results will be presented in comparison with numerical simulations.
Space charge lenses using a stable electron cloud for focusing low energy heavy ion beams are an alternative concept to conventional ion optics. Due to external fields electrons are confined inside the lens’ volume. In case of a homogeneously distributed electron cloud the linear electric space charge field enables beam focusing free of aberration. Since the mapping quality of the lens is related to the confinement, non-destructive diagnostics has been developed to determine the plasma parameters and to characterize the collective behavior of the confined nonneutral plasma. Moreover, a scaled up space charge lens was constructed for a detailed investigation of the nonneutral plasma properties as well as beam interactions with a stable confined electron cloud. Experimental results will be presented in comparison with numerical simulations.
The SIS300 synchrotron, planned for the new Facility for Antiproton and Ion Research (FAIR) at GSI-Darmstadt, will become the first superconducting synchrotron worldwide using cos(θ) magnets for resonant slow extraction. A multi-objective optimization algorithm has been developed for the design of the non-linear magnet scheme. The optimization algorithm makes use of the analytical model for the slow extraction from Kobayashi, the analytical description of the resonance excitation and amplitude-dependent tune-shift from Bengtsson, and corrects the chromaticity in order to fulfill the Hardt condition. As a result, the placement of the chromatic and harmonic sextupole magnets in SIS300, the number of sextupole families and the gradients of these families have been optimized for a high efficiency slow extraction. The algorithm accounts also for the sextupole errors on the dipole magnets, compensating its effects. Furthermore, optimized time-dependent settings for the sextupole magnets are generated to compensate the persistent current decay occurring at slow extraction. Tolerances for the magnets are set for the limits where the compensation is no longer valid.
A non-interceptive optical diagnostic system on the basis of beam tomography, was developed for the planned Frankfurt Neutron Source (FRANZ). The proton driver linac of FRANZ will provide energies up to 2.0 MeV. The measurement device will non-interceptively derive required beam parameters at the end of the LEBT at beam energies of 120 keV and a current of 200 mA. On a narrow space of 351.2 mm length a rotatable tomography tank will perform a multi-turn tomography with a high and stable vacuum pressure. The tank allows to plug different measurement equipment additionally to the CCD Camera installed, to perform optical beam tomography. A collection of developed algorithms provides information about the density distribution, shape, size, location and emittance on the basis of CCD images. Simulated, as well as measured data have been applied to the evaluation algorithms to test the reliability of the beam. The actual contribution gives an overview on the current diagnostic possibilities of this diagnostic system.
This novel kind of neutron beam facility will provide 1 ns short neutron pulses with an approximately thermal energy distribution around 30 keV. The pulse repetition rate will be up to 250 kHz, the total proton number per pulse will be up to 6×1010 in the final stage, starting with a p – source current of 200 mA. A second target station will allow n – activation experiments by cw beam operation. An intense 2 MeV proton beam will drive a neutron source by the 7 Li (p,n) 7 Be reaction. The facility is under construction at the physics experimental hall of the J.W. Goethe – University. The 1m thick concrete tunnel was installed in 2009. In 2011 all rf amplifiers will be delivered and installed. Successful 200 mA proton source experiments in 2010 at a test stand will be followed by experiments on the 120 kV FRANZ terminal in 2011. The 250 kHz, 100 ns chopper in front of the rf linac is under construction, while the 2 MeV bunch compressor design was finished and the technical design of all components has started. The main accelerator cavity is under construction. First 2 MeV beam tests are expected for end of 2012.
SIS100 is the main synchrotron of the FAIR project. It is designed to accelerate high intensity intermediate charge state uranium beams from 200 MeV/u up to 2.7 GeV/u. Intermediate charge state heavy ions are exposed to a high probability of charge exchange due to collisions with residual gas molecules. Since the charge exchange process changes the magnetic rigidity, the involved ions are lost behind dispersive elements, and an energy-dependent gas desorption takes place. The StrahlSim code has been used to predict the stability of the residual gas pressure in SIS100 under beam loss driven dynamic conditions. The results show, that a stable operation at highest U28+ intensities is possible, under the constraint that the vacuum chambers of the ion catcher system are cold enough to pump hydrogen. Furthermore, in order to determine the load to the cryogenic system, the average beam energy deposition onto the ion catcher system has been calculated.