Refine
Year of publication
Document Type
- Article (31)
- Conference Proceeding (3)
- Preprint (1)
- Review (1)
Has Fulltext
- yes (36)
Is part of the Bibliography
- no (36)
Keywords
- SARS-CoV-2 (9)
- PCR (7)
- COVID-19 (6)
- HBV (2)
- HCV (2)
- Viruslast (2)
- cell culture (2)
- influenza (2)
- out-patient paediatrics (2)
- respiratory tract infection (2)
Institute
Despite multidisciplinary local and systemic therapeutic approaches, the prognosis for most patients with brain metastases is still dismal. The role of adaptive and innate anti-tumor response including the Human Leukocyte Antigen (HLA) machinery of antigen presentation is still unclear. We present data on the HLA class II-chaperone molecule CD74 in brain metastases and its impact on the HLA peptidome complexity.
We analyzed CD74 and HLA class II expression on tumor cells in a subset of 236 human brain metastases, primary tumors and peripheral metastases of different entities in association with clinical data including overall survival. Additionally, we assessed whole DNA methylome profiles including CD74 promoter methylation and differential methylation in 21 brain metastases. We analyzed the effects of a siRNA mediated CD74 knockdown on HLA-expression and HLA peptidome composition in a brain metastatic melanoma cell line.
We observed that CD74 expression on tumor cells is a strong positive prognostic marker in brain metastasis patients and positively associated with tumor-infiltrating T-lymphocytes (TILs). Whole DNA methylome analysis suggested that CD74 tumor cell expression might be regulated epigenetically via CD74 promoter methylation. CD74high and TILhigh tumors displayed a differential DNA methylation pattern with highest enrichment scores for antigen processing and presentation. Furthermore, CD74 knockdown in vitro lead to a reduction of HLA class II peptidome complexity, while HLA class I peptidome remained unaffected.
In summary, our results demonstrate that a functional HLA class II processing machinery in brain metastatic tumor cells, reflected by a high expression of CD74 and a complex tumor cell HLA peptidome, seems to be crucial for better patient prognosis.
In resource-limited or point-of-care settings, rapid diagnostic tests (RDTs), that aim to simultaneously detect HIV antibodies and p24 capsid (p24CA) antigen with high sensitivity, can pose important alternatives to screen for early infections. We evaluated the performance of the antibody and antigen components of the old and novel version of the Determine™ HIV-1/2 Ag/Ab Combo RDTs in parallel to quantifications in a fourth-generation antigen/antibody immunoassay (4G-EIA), p24CA antigen immunoassay (p24CA-EIA), immunoblots, and nucleic acid quantification. We included plasma samples of acute, treatment-naïve HIV-1 infections (Fiebig stages I–VI, subtypes A1, B, C, F, CRF02_AG, CRF02_AE, URF) or chronic HIV-1 and HIV-2 infections. The tests’ antigen component was evaluated also for a panel of subtype B HIV-1 transmitted/founder (T/F) viruses, HIV-2 strains and HIV-2 primary isolates. Furthermore, we assessed the analytical sensitivity of the RDTs to detect p24CA using a highly purified HIV-1NL4-3 p24CA standard. We found that 77% of plasma samples from acutely infected, immunoblot-negative HIV-1 patients in Fiebig stages II–III were identified by the new RDT, while only 25% scored positive in the old RDT. Both RDTs reacted to all samples from chronically HIV-1-infected and acutely HIV-1-infected patients with positive immunoblots. All specimens from chronically infected HIV-2 patients scored positive in the new RDT. Of note, the sensitivity of the RDTs to detect recombinant p24CA from a subtype B virus ranged between 50 and 200 pg/mL, mirrored also by the detection of HIV-1 T/F viruses only at antigen concentrations tenfold higher than suggested by the manufacturer. The RTD failed to recognize any of the HIV-2 viruses tested. Our results indicate that the new version of the Determine™ HIV-1/2 Ag/Ab Combo displays an increased sensitivity to detect HIV-1 p24CA-positive, immunoblot-negative plasma samples compared to the precursor version. The sensitivity of 4G-EIA and p24CA-EIA to detect the major structural HIV antigen, and thus to diagnose acute infections prior to seroconversion, is still superior.
An accurate quantification of low viremic HCV RNA plasma samples has gained importance since the approval of direct acting antivirals and since only one single measurement predicts the necessity of a prolonged or shortened therapy. As reported previously, HCV quantification assays such as Abbott RealTime HCV and Roche COBAS AmpliPrep/COBAS TaqMan HCV version 2 (CTM v2) may vary in sensitivity and precision particularly in low-level viremia. Importantly, substantial variations were previously demonstrated between some of these assays compared to the Roche High Pure System/COBAS TaqMan assay (HPS) reference assay, which was used to establish the clinical decision points in clinical studies. In this study, the reproducibility of assay performances across several laboratories was assessed by analysing quantification results generated by six independent laboratories (3× RealTime, 3× CTM v2) in comparison with one HPS reference laboratory. The 4th WHO Standard was diluted to 100, 25 and 10 IU/ml, and aliquots were tested in triplicates in 5 independent runs by each assay in the different laboratories to assess assay precision and detection rates. In a second approach, 2 clinical samples (GT 1a & GT 1b) were diluted to 100 and 25 IU/ml and tested as described above. While the result range for WHO 100 IU/ml replicates across all laboratories was similar in this analysis, the CVs of each laboratory ranged from 19.3 to 25.6 % for RealTime laboratories and were lower than CVs of CTM v2 laboratories with a range of 26.1–47.3 %, respectively, and also in comparison with the CV of the HPS reference laboratory (34.9 %). At WHO standard dilution of 25 IU/ml, 24 replicates were quantified by RealTime compared to 8 replicates with CTM v2. Results of clinical samples again revealed a higher variation of CTM v2 results as compared to RealTime values. (CVs at 100 IU/ml: RealTime: 13.1–21.0 % and CTM v2: 15.0–32.3 %; CVs at 25 IU/ml: RealTime 17.6–34.9 % and CTM v2 28.2–54.9 %). These findings confirm the superior precision of RealTime versus CTM v2 at low-level viremia even across different laboratories including the new clinical decision point at 25 IU/ml. A highly precise monitoring of HCV viral load during therapy will remain crucial for patient management with regard to futility rules, therapy efficacy and SVR.
Background: International travel is a major driver of the introduction and spread of SARS- CoV-2. Aim: To investigate SARS-CoV-2 genetic diversity in the region of a major transport hub in Germany, we characterized the viral sequence diversity of the SARS-CoV-2 variants circulating in Frankfurt am Main, the city with the largest airport in Germany, from the end of October to the end of December 2020. Methods: In total, we recovered 136 SARS-CoV-2 genomes from nasopharyngeal swab samples. We isolated 104 isolates that were grown in cell culture and RNA from the recovered viruses and subjected them to full-genome sequence analysis. In addition, 32 nasopharyngeal swab samples were directly sequenced. Results and conclusion: We found 28 different lineages of SARS- CoV-2 circulating during the study period, including the variant of concern B.1.1.7 (∆69/70, N501Y). Six of the lineages had not previously been observed in Germany. We detected the spike protein (S) deletion ∆69/∆70 in 15% of all sequences, a four base pair (bp) deletion (in 2.9% of sequences) and a single bp deletion (in 0.7% of sequences) in ORF3a, leading to ORF3a truncations. In four sequences (2.9%), an amino acid deletion at position 210 in S was identified. In a single sample (0.7%), both a 9 bp deletion in ORF1ab and a 7 bp deletion in ORF7a were identified. One sequence in lineage B.1.1.70 had an N501Y substitution while lacking the ∆69/70 in S. The high diversity of sequences observed over two months in Frankfurt am Main highlights the persisting need for continuous SARS-CoV-2 surveillance using full-genome sequencing, particularly in cities with international airport connections.
Purpose: Severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) replicates predominantly in the upper respiratory tract and is primarily transmitted by droplets and aerosols. Taking the medical history for typical COVID-19 symptoms and PCR-based SARS-CoV-2 testing have become established as screening procedures. The aim of this work was to describe the clinical appearance of SARS-CoV-2-PCR positive patients and to determine the SARS-CoV-2 contact risk for health care workers (HCW).
Methods: The retrospective study included n = 2283 SARS-CoV-2 PCR tests from n = 1725 patients with otorhinolaryngological (ORL) diseases performed from March to November 2020 prior to inpatient treatment. In addition, demographic data and medical history were assessed.
Results: n = 13 PCR tests (0.6%) were positive for SARS-CoV-2 RNA. The positive rate showed a significant increase during the observation period (p < 0.01). None of the patients had clinical symptoms that led to a suspected diagnosis of COVID-19 before PCR testing. The patients were either asymptomatic (n = 4) or had symptoms that were interpreted as symptoms typical of the ORL disease or secondary diagnoses (n = 9).
Conclusion: The identification of SARS-CoV-2-positive patients is a considerable challenge in clinical practice. Our findings illustrate that taking a medical history alone is of limited value and cannot replace molecular SARS-CoV-2 testing, especially for patients with ORL diseases. Our data also demonstrate that there is a high probability of contact with SARS-CoV-2-positive patients in everyday clinical practice, so that the use of personal protective equipment, even in apparently “routine cases”, is highly recommended.
Highly sensitive qualitative and quantitative automatednucleic acid amplification tests (NATs) that are commercially available for the detection of hepatitis B virus (HBV)infection have been developed only in the last few years.The potential indications for HBV NATs are: follow-up ofchronic hepatitis B, therapy and antiviral resistance monitoring, determination of infectivity and transmission risk,detection of occult (HBsAg-negative and HBV DNA-positive) infection and mutant virus which may escape serologic diagnosis, blood donor screening, and resolution ofunusual or discordant serologic constellations. Although NATs are now widely implemented in the routine diagnosis of clinical laboratories, there are several importantissues which need to be further investigated. Standardisation of NATs used for the monitoring of antiviral therapyand follow-up of chronic infection is still lacking, and theclinical significance of HBV DNA levels needs to be clarified. The influence of genetic variability in terms of genotype variation has been poorly investigated so far.Although there are highly sensitive automated NATs forblood donor screening available, their implementation is still subject to discussion and certain countries rejectedHBV DNA testing for blood donation for reasons of poor cost-effectiveness.
Background and Aims: The prevalence of hepatitis C virus (HCV) antibodies in Germany has been estimated to be in the range of 0.4–0.63%. Screening for HCV is recommended in patients with elevated ALT levels or significant risk factors for HCV transmission only. However, 15–30% of patients report no risk factors and ALT levels can be normal in up to 20–30% of patients with chronic HCV infection. The aim of this study was to assess the HCV seroprevalence in patients visiting two tertiary care emergency departments in Berlin and Frankfurt, respectively.
Methods: Between May 2008 and March 2010, a total of 28,809 consecutive patients were screened for the presence of anti-HCV antibodies. Anti-HCV positive sera were subsequently tested for HCV-RNA.
Results: The overall HCV seroprevalence was 2.6% (95% CI: 2.4–2.8; 2.4% in Berlin and 3.5% in Frankfurt). HCV-RNA was detectable in 68% of anti-HCV positive cases. Thus, the prevalence of chronic HCV infection in the overall study population was 1.6% (95% CI 1.5–1.8). The most commonly reported risk factor was former/current injection drug use (IDU; 31.2%) and those with IDU as the main risk factor were significantly younger than patients without IDU (p<0.001) and the male-to-female ratio was 72% (121 vs. 46 patients; p<0.001). Finally, 18.8% of contacted HCV-RNA positive patients had not been diagnosed previously.
Conclusions: The HCV seroprevalence was more than four times higher compared to current estimates and almost one fifth of contacted HCV-RNA positive patients had not been diagnosed previously.
Background and Aims: Chronic infection with the hepatitis B virus (HBV) is a major health issue worldwide. Recently, single nucleotide polymorphisms (SNPs) within the human leukocyte antigen (HLA)-DP locus were identified to be associated with HBV infection in Asian populations. Most significant associations were observed for the A alleles of HLA-DPA1 rs3077 and HLA-DPB1 rs9277535, which conferred a decreased risk for HBV infection. We assessed the implications of these variants for HBV infection in Caucasians.
Methods: Two HLA-DP gene variants (rs3077 and rs9277535) were analyzed for associations with persistent HBV infection and with different clinical outcomes, i.e., inactive HBsAg carrier status versus progressive chronic HBV (CHB) infection in Caucasian patients (n = 201) and HBsAg negative controls (n = 235).
Results: The HLA-DPA1 rs3077 C allele was significantly associated with HBV infection (odds ratio, OR = 5.1, 95% confidence interval, CI: 1.9–13.7; p = 0.00093). However, no significant association was seen for rs3077 with progressive CHB infection versus inactive HBsAg carrier status (OR = 2.7, 95% CI: 0.6–11.1; p = 0.31). In contrast, HLA-DPB1 rs9277535 was not associated with HBV infection in Caucasians (OR = 0.8, 95% CI: 0.4–1.9; p = 1).
Conclusions: A highly significant association of HLA-DPA1 rs3077 with HBV infection was observed in Caucasians. However, as a differentiation between different clinical courses of HBV infection was not possible, knowledge of the HLA-DPA1 genotype cannot be translated into personalized anti-HBV therapy approaches.
The novel coronavirus SARS-CoV-2 is the causative agent of the acute respiratory disease COVID-19, which has become a global concern due to its rapid spread. Meanwhile, increased demand for testing has led to a shortage of reagents and supplies and compromised the performance of diagnostic laboratories in many countries. Both the World Health Organization (WHO) and the Center for Disease Control and Prevention (CDC) recommend multi-step RT-PCR assays using multiple primer and probe pairs, which might complicate the interpretation of the test results, especially for borderline cases. In this study, we describe an alternative RT-PCR approach for the detection of SARS-CoV-2 RNA that can be used for the probe-based detection of clinical isolates in diagnostics as well as in research labs using a low-cost SYBR green method. For the evaluation, we used samples from patients with confirmed SARS-CoV-2 infections and performed RT-PCR assays along with successive dilutions of RNA standards to determine the limit of detection. We identified an M-gene binding primer and probe pair highly suitable for the quantitative detection of SARS-CoV-2 RNA for diagnostic and research purposes.
Die HIV-1-Resistenztestung wird ein immer bedeutenderer Bestandteil des Monitorings der antiretroviralen Therapie und erfolgt in der Regel mittels Genotypisierung. Zur Zeit sind zwei Systeme kommerziell erhältlich und obwohl diese technisch nicht zu den einfach durchführbaren Methoden gehören, haben sie doch einen hohen Grad an Qualität erreicht. Modifikationen der Standardprotokolle sind für bestimmte Fragestellungen durchaus von Vorteil. Obwohl beide Systeme auf Entscheidungsregeln basierende Resistenz-Reports beinhalten, braucht es das zusätzliche Wissen und die Erfahrung des Anwenders, um die detektierten Mutationsmuster in klinisch brauchbare Resultate überführen zu können. Beide der hier detailliert beschriebenen Systeme haben ihre Vor- und Nachteile. Die Entscheidung für das eine oder andere System muss aufgrund der individuellen Bedürfnisse getroffen werden. Microarray-Systemen könnte der Markt der Zukunft gehören.