Refine
Year of publication
Document Type
- Article (71)
- Preprint (16)
- Conference Proceeding (1)
Has Fulltext
- yes (88)
Is part of the Bibliography
- no (88)
Keywords
- LHC (8)
- ALICE (3)
- ALICE experiment (3)
- pp collisions (3)
- Anschlussheilbehandlung (2)
- Auditory rehabilitation (2)
- Beauty production (2)
- Cochleaimplantation (2)
- Cochlear implant (2)
- Cochlear implantation (2)
Institute
- Physik (70)
- Frankfurt Institute for Advanced Studies (FIAS) (62)
- Informatik (62)
- Medizin (18)
A measurement of the transverse momentum spectra of jets in Pb-Pb collisions at sNN−−−√=2.76 TeV is reported. Jets are reconstructed from charged particles using the anti-kT jet algorithm with jet resolution parameters R of 0.2 and 0.3 in pseudo-rapidity |η|<0.5. The transverse momentum pT of charged particles is measured down to 0.15 GeV/c which gives access to the low pT fragments of the jet. Jets found in heavy-ion collisions are corrected event-by-event for average background density and on an inclusive basis (via unfolding) for residual background fluctuations and detector effects. A strong suppression of jet production in central events with respect to peripheral events is observed. The suppression is found to be similar to the suppression of charged hadrons, which suggests that substantial energy is radiated at angles larger than the jet resolution parameter R=0.3 considered in the analysis. The fragmentation bias introduced by selecting jets with a high pT leading particle, which rejects jets with a soft fragmentation pattern, has a similar effect on the jet yield for central and peripheral events. The ratio of jet spectra with R=0.2 and R=0.3 is found to be similar in Pb-Pb and simulated PYTHIA pp events, indicating no strong broadening of the radial jet structure in the reconstructed jets with R<0.3.
Background: Although noise is one of the leading work-related health risk factors for teachers, many nursery schools lack sufficient noise reduction measures. Methods: This intervention study evaluated the noise exposure of nursery school teachers when dropping DUPLO toy bricks into storage cases. Sound analyses of the impact included assessment of the maximum sound pressure level (LAFmax) as well as frequency analyses with 1/3 octave band filter. For the purpose of standardization, a customized gadget was developed. Recordings were performed in 11 cases of different materials and designs to assess the impact on sound level reduction. Thereby, the acoustic effects of three damping materials (foam rubber, carpet, and PU-foam) were investigated. Results: The lowest LAFmax was measured in cases consisting of “metal grid” (90.71 dB) or of a woven willow “basket” (91.61 dB), whereas a case of “aluminium” (103.34 dB) generated the highest impact LAFmax. The frequency analyses determined especially low LAFmax in the frequency bands between 80 and 2500 Hz in cases designs “metal grid” and “basket”. The insertion of PU-foam achieved the most significant attenuation of LAFmax (−13.88 dB) and, in the frequency analyses, the best sound damping. Conclusion: The dropping of DUPLO bricks in cases contributes to the high noise level in nursery schools, but measured LAFmax show no evidence for the danger of acute hearing loss. However, continuous exposure may lead to functional impairment of the hair cells and trigger stress reactions. We recommend noise reduction by utilizing cases of woven “basket” with an insert of PU-foam.
Previous studies in patients with single-sided deafness (SSD) have reported results of pitch comparisons between electric stimulation of their cochlear implant (CI) and acoustic stimulation presented to their near-normal hearing contralateral ear. These comparisons typically used sinusoids, although the percept elicited by electric stimulation may be closer to a wideband stimulus. Furthermore, it has been shown that pitch comparisons between sounds with different timbres is a difficult task and subjected to various types of range biases. The present study aims to introduce a method to minimize non-sensory biases, and to investigate the effect of different acoustic stimulus types on the frequency and variability of the electric-acoustic pitch matches. Pitch matches were collected from 13 CI users with SSD using the binary search procedure. Electric stimulation was presented at either an apical or a middle electrode position, at a rate of 800 pps. Acoustic stimulus types were sinusoids (SINE), 1/3-octave wide narrow bands of Gaussian noises (NBN), or 1/3-octave wide pulse spreading harmonic complexes (PSHC). On the one hand, NBN and PSHC are presumed to better mimic the spread of excitation produced by a single-electrode stimulation than SINE. On the other hand, SINE and PSHC contain less inherent fluctuations than NBN and may therefore provide a temporal pattern closer to that produced by a constant-amplitude electric pulse train. Analysis of mean pitch match variance showed no differences between stimulus types. However, mean pitch matches showed effects of electrode position and stimulus type, with the middle electrode always matched to a higher frequency than the apical one (p < 0.001), and significantly higher across-subject pitch matches for PSHC compared with SINE (p = 0.017). Mean pitch matches for all stimulus types were better predicted by place-dependent characteristic frequencies (CFs) based on an organ of Corti map compared with a spiral ganglion map. CF predictions were closest to pitch matches with SINE for the apical electrode position, and conversely with NBN or PSHC for the middle electrode position. These results provide evidence that the choice of acoustic stimulus type can have a significant effect on electric-acoustic pitch matching.
Clinical speech perception tests with simple presentation conditions often overestimate the impact of signal preprocessing on speech perception in complex listening environments. A new procedure was developed to assess speech perception in interleaved acoustic environments of different complexity that allows investigation of the impact of an automatic scene classification (ASC) algorithm on speech perception. The procedure was applied in cohorts of normal hearing (NH) controls and uni- and bilateral cochlear implant (CI) users. Speech reception thresholds (SRTs) were measured by means of a matrix sentence test in five acoustic environments that included different noise conditions (amplitude modulated and continuous), two spatial configurations, and reverberation. The acoustic environments were encapsulated in a randomized, mixed order single experimental run. Acoustic room simulation was played back with a loudspeaker auralization setup with 128 loudspeakers. 18 NH, 16 unilateral, and 16 bilateral CI users participated. SRTs were evaluated for each individual acoustic environment and as mean-SRT. Mean-SRTs improved by 2.4 dB signal-to-noise ratio for unilateral and 1.3 dB signal-to-noise ratio for bilateral CI users with activated ASC. Without ASC, the mean-SRT of bilateral CI users was 3.7 dB better than the SRT of unilateral CI users. The mean-SRT indicated significant differences, with NH group performing best and unilateral CI users performing worse with a difference of up to 13 dB compared to NH. The proposed speech test procedure successfully demonstrated that speech perception and benefit with ASC depend on the acoustic environment.
Objectives: Combined electric-acoustic stimulation (EAS) is a well-accepted therapeutic treatment for cochlear implant (CI) users with residual hearing in the low frequencies but severe to profound hearing loss in the high frequencies. The recently introduced SONNETeas audio processor offers different microphone directionality (MD) settings and wind noise reduction (WNR) as front-end processing. The aim of this study was to compare speech perception in quiet and noise between two EAS audio processors DUET 2 and SONNETeas, to assess the impact of MD and WNR on speech perception in EAS users in the absence of wind. Furthermore, subjective rating of hearing performance was registered.
Method: Speech perception and subjective rating with SONNETeas or DUET 2 audio processor were assessed in 10 experienced EAS users. Speech perception was measured in quiet and in a diffuse noise setup (MSNF). The SONNETeas processor was tested with three MD settings omnidirectional/natural/adaptive and with different intensities of WNR. Subjective rating of auditory benefit and sound quality was rated using two questionnaires.
Results: There was no significant difference between DUET 2 and SONNETeas processor using the omnidirectional microphone in quiet and in noise. There was a significant improvement in SRT with MD settings natural (2.2 dB) and adaptive (3.6 dB). No detrimental effect of the WNR algorithm on speech perception was found in the absence of wind. Sound quality was rated as “moderate” for both audio processors.
Conclusions: The different MD settings of the SONNETeas can provide EAS users with better speech perception compared to an omnidirectional microphone. Concerning speech perception in quiet and quality of life, the performance of the DUET 2 and SONNETeas audio processors was comparable.
Objectives: In this study, localization accuracy and sensitivity to acoustic interaural time differences (ITDs) in subjects using cochlear implants with combined electric-acoustic stimulation (EAS) were assessed and compared with the results of a normal hearing control group. Methods: Eight CI users with EAS (2 bilaterally implanted, 6 unilaterally implanted) and symmetric binaural acoustic hearing and 24 normal hearing subjects participated in the study. The first experiment determined mean localization error (MLE) for different angles of sound incidence between ± 60° (frontal and dorsal presentation). The stimuli were either low-pass, high-pass or broadband noise bursts. In a second experiment, just noticeable differences (JND) of ITDs were measured for pure tones of 125 Hz, 250 Hz and 500 Hz (headphone presentation). Results: Experiment 1: MLE of EAS subjects was 8.5°, 14.3° and 14.7°, (low-, high-pass and broadband stimuli respectively). In the control group, MLE was 1.8° (broadband stimuli). In the differentiation between sound incidence from front and back, EAS subjects performed on chance level. Experiment 2: The JND-ITDs were 88.7 μs for 125 Hz, 48.8 μs for 250 Hz and 52.9 μs for 500 Hz (EAS subjects). Compared to the control group, JND-ITD for 125 Hz was on the same level of performance. No statistically significant correlation was found between MLE and JND-ITD in the EAS cohort. Conclusions: Near to normal ITD sensitivity in the lower frequency acoustic hearing was demonstrated in a cohort of EAS users. However, in an acoustic localization task, the majority of the subjects did not reached the level of accuracy of normal hearing. Presumably, signal processing time delay differences between devices used on both sides are deteriorating the transfer of precise binaural timing cues.
Nowadays, several options are available to treat patients with conductive or mixed hearing loss. Whenever surgical intervention is not possible or contra-indicated, and amplification by a conventional hearing device (e.g., behind-the-ear device) is not feasible, then implantable hearing devices are an indispensable next option. Implantable bone-conduction devices and middle-ear implants have advantages but also limitations concerning complexity/invasiveness of the surgery, medical complications, and effectiveness. To counsel the patient, the clinician should have a good overview of the options with regard to safety and reliability as well as unequivocal technical performance data. The present consensus document is the outcome of an extensive iterative process including ENT specialists, audiologists, health-policy scientists, and representatives/technicians of the main companies in this field. This document should provide a first framework for procedures and technical characterization to enhance effective communication between these stakeholders, improving health care.
Hintergrund und Fragestellung: Die Severe acute respiratory syndrome coronavirus type 2(SARS-CoV-2)-Pandemie hat die Ausbildung von Medizinstudierenden grundlegend verändert. Die Notwendigkeit von Kontaktbeschränkungen und die damit einhergehende Forderung nach Distanzunterricht hat dazu geführt, dass innerhalb kurzer Zeit digitale Lehrformate umgesetzt werden mussten. Ziel dieser Arbeit war die Auswertung der studentischen Evaluationsergebnisse für virtuellen Unterricht im Fach Hals-Nasen-Ohren-Heilkunde während der SARS-CoV-2-Pandemie und ein Vergleich mit den zuvor erhobenen Evaluationsergebnissen unter Präsenzbedingungen.
Material und Methoden: Untersucht wurden die Evaluationsergebnisse für die Blockpraktika im Wintersemester 2020/21 und im Sommersemester 2021, die in einem virtuellen Format mit kurzer Präsenzphase durchgeführt wurden, sowie die der komplett im konventionellen Präsenzformat durchgeführten Praktika von Sommersemester 2018 bis Wintersemester 2019/20. Die anonyme Befragung der Studierenden bezog sich auf verschiedene Aspekte der Lehrveranstaltung, wie z. B. Organisation, Didaktik und Lernatmosphäre.
Ergebnisse: Von 16 abgefragten Kategorien zeigten 14 (87,5%) signifikant bessere Evaluationsergebnisse für die virtuellen Praktika verglichen mit den zuvor im Präsenzformat durchgeführten Praktika. Diese sehr positive Bewertung des digitalen Lehrangebots zeigte im Pandemieverlauf über die Dauer von zwei Semestern keine signifikante Änderung.
Schlussfolgerung: Die vorliegenden Daten belegen die hohe Akzeptanz eines digitalen Lehrangebots im Fach HNO-Heilkunde für Studierende. Auch wenn unerlässliche Bestandteile der ärztlichen Ausbildung, wie der Unterricht am Patienten und das Erlernen klinisch-praktischer Fertigkeiten, weiterhin nur im Präsenzformat realisiert werden können, legen die Ergebnisse nahe, dass digitale Elemente auch nach der SARS-CoV-2-Pandemie eine Rolle im Medizinstudium spielen könnten.
Objective: Vertigo is a common side effect of cochlear implant (CI) treatment. This prospective study examines the incidence of postoperative vertigo over time and aims to analyze influencing factors such as electrode design and insertion angle (IA).
Study Design and Setting: This is a prospective study which has been conducted at a tertiary referral center (academic hospital).
Patients: A total of 29 adults were enrolled and received a unilateral CI using one of six different electrode carriers, which were categorized into “structure-preserving” (I), “potentially structure-preserving” (II), and “not structure-preserving” (III).
Intervention: Subjective vertigo was assessed by questionnaires at five different time-points before up to 6 months after surgery. The participants were divided into four groups depending on the time of the presence of vertigo before and after surgery. Preoperatively and at 6 months postoperatively, a comprehensive vertigo diagnosis consisting of Romberg test, Unterberger test, subjective visual vertical, optokinetic test, video head impulse test, and caloric irrigation test was performed. In addition, the IA was determined, and the patients were divided in two groups (<430°; ≥430°).
Main Outcome Measures: The incidence of vertigo after CI surgery (group 1) was reported, as well as the correlation of subjective vertigo with electrode array categories (I–III) and IA.
Results: Among the participants, 45.8% experienced new vertigo after implantation. Based on the questionnaire data, a vestibular origin was suspected in 72.7%. The results did not show a significant correlation with subjective vertigo for any of the performed tests. In group 1 with postoperative vertigo, 18% of patients showed conspicuous results in a quantitative analysis of caloric irrigation test despite the fact that the category I or II electrodes were implanted, which are suitable for structure preservation. Average IA was 404° for the overall group and 409° for group 1. There was no statistically significant correlation between IA and perceived vertigo.
Conclusions: Though vertigo after CI surgery seems to be a common complication, the test battery used here could not objectify the symptoms. Further studies should clarify whether this is due to the multifactorial cause of vertigo or to the lack of sensitivity of the tests currently in use. The proof of reduced probability for vertigo when using atraumatic electrode carrier was not successful, nor was the proof of a negative influence of the insertion depth.
The ALICE Collaboration at the LHC reports measurement of the inclusive production cross section of electrons from semi-leptonic decays of beauty hadrons with rapidity |y| < 0.8 and transverse momentum 1 < pT < 10 GeV/c, in pp collisions at √s = 2.76 TeV. Electrons not originating from semi-electronic decay of beauty hadrons are suppressed using the impact parameter of the corresponding tracks. The production cross section of beauty decay electrons is compared to the result obtained with an alternative method which uses the distribution of the azimuthal angle between heavy-flavour decay electrons and charged hadrons. Perturbative QCD predictions agree with the measured cross section within the experimental and theoretical uncertainties. The integrated visible cross section, σb→e = 3.47 ± 0.40(stat) +1.12 −1.33(sys) ± 0.07(norm) μb, was extrapolated to full phase space using Fixed Order plus Next-to-Leading Log (FONLL) calculations to obtain the total bb production ¯ cross section, σbb¯ = 130 ± 15.1(stat) +42.1 −49.8(sys) +3.4 −3.1(extr) ± 2.5(norm) ± 4.4(BR) μb.