Refine
Document Type
- Article (4)
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
- image distortion (1)
- needle displacement (1)
- prostate brachytherapy (1)
- ultrasound (1)
Institute
- Biochemie und Chemie (3)
- Medizin (1)
The title compound, C17H18N2O6, crystallizes with two molecules in the asymmetric unit. In both molecules, one of the C-C bonds of the pentamethylene chain connecting the two aromatic rings is in a trans conformation and another displays a gauche conformation. The aromatic rings within each molecule are nearly coplanar [dihedral angles = 3.36 (9) and 4.50 (9)°] and the nitro groups are twisted slightly out of the planes of their attached rings [dihedral angles = 8.16 (3)/6.6 (2) and 4.9 (4)/3.8 (3)°]. Key indicators: single-crystal X-ray study; T = 173 K; mean σ(C–C) = 0.003 Å; R factor = 0.040; wR factor = 0.101; data-to-parameter ratio = 13.5.
The molecule of the title compound, C14H16N2O2, is located on a crystallographic twofold rotation axis. The central O-C-C-O bridge adopts a gauche conformation. One of the amine H atoms is disordered over two equally occupied positions. The crystal structure is stabilized by N-H...O and N-H...N hydrogen bonds. Key indicators: single-crystal X-ray study; T = 173 K; mean σ(C–C) = 0.002 Å; disorder in main residue; R factor = 0.049; wR factor = 0.119; data-to-parameter ratio = 17.9.
In the title compound, C27H16F6N2O6, the nitro groups are almost coplanar with the aromatic rings to which they are attached [dihedral angles = 3.5 (5) and 6.2 (3)°]. The dihedral angles between adjacent aromatic rings are 78.07 (8) and 71.11 (8)° for nitrophenyl/phenyl and 69.50 (8)° for phenyl/phenyl. An intermolecular C-H...[pi] interaction seems to be effective in the stabilization of the structure. Key indicators: single-crystal X-ray study; T = 173 K; mean σ(C–C) = 0.004 Å; R factor = 0.045; wR factor = 0.092; data-to-parameter ratio = 12.5.
PURPOSE: This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation of currently established water-bath based quality assurance (QA) procedures is presented.
MATERIAL AND METHODS: Image acquisitions of an ultrasound QA setup were carried out at 5 MHz and 7 MHz. The U/S probe was covered by EA 4015 Silicone Standoff kit, or UA0059 Endocavity balloon filled either with water or one of the following: 40 ml of Endosgel(®), Instillagel(®), Ultraschall gel or Space OAR™ gel. The differences between images were recorded. Consequently, the dosimetric impact of the observed image distortion was investigated, using a tissue equivalent ultrasound prostate phantom - Model number 053 (CIRS Inc., Norfolk, VA, USA).
RESULTS: By using the EA 4015 Silicone Standoff kit in normal water with sound speed of 1525 m/s, a 3 mm needle shift was observed. The expansion of objects appeared in radial direction. The shift deforms also the PTV (prostate in our case) and other organs at risk (OARs) in the same way leading to overestimation of volume and underestimation of the dose. On the other hand, Instillagel(®) and Space OAR™ "shrinks" objects in an ultrasound image for 0.65 mm and 0.40 mm, respectively.
CONCLUSIONS: The use of EA 4015 Silicone Standoff kit for image acquisition, leads to erroneous contouring of PTV and OARs and reconstruction and placement of catheters, which results to incorrect dose calculation during prostate brachytherapy. Moreover, the reliability of QA procedures lies mostly in the right temperature of the water used for accurate simulation of real conditions of transrectal ultrasound imaging.