Refine
Year of publication
- 2020 (123) (remove)
Document Type
- Preprint (65)
- Article (57)
- Working Paper (1)
Language
- English (123) (remove)
Has Fulltext
- yes (123)
Is part of the Bibliography
- no (123)
Keywords
- Hadron-Hadron scattering (experiments) (6)
- Heavy Ion Experiments (4)
- Heavy-ion collision (3)
- Particle and resonance production (2)
- 16S rRNA sequencing (1)
- ADAMTS-13 (1)
- ADHD (1)
- ATR-FTIR (1)
- Abundance (1)
- Accelerators & Beams (1)
Institute
- Physik (114)
- Frankfurt Institute for Advanced Studies (FIAS) (98)
- Informatik (93)
- Medizin (7)
- Biowissenschaften (1)
- Center for Financial Studies (CFS) (1)
- ELEMENTS (1)
- Frankfurt MathFinance Institute (FMFI) (1)
- House of Finance (HoF) (1)
- Sportwissenschaften (1)
- Sustainable Architecture for Finance in Europe (SAFE) (1)
- Wirtschaftswissenschaften (1)
Background: Conditions during blood product storage and transportation should maintain quality. The aim of this in vitro study was to investigate the effect of interruption of agitation, temporary cooling (TC), and pneumatic tube system transportation (PTST) on the aggregation ability (AA) and mitochondrial function (MF) of platelet concentrates (PC).
Study Design and Methods: A PC was divided equally into four subunits and then allocated to four test groups. The control group (I) was stored as recommended (continuous agitation, 22 ± 2°C) for 4 days. The test groups were stored without agitation (II), stored as recommended, albeit 4°C for 60 minutes on day (d)2 (III) and PTST (IV). Aggregometry was measured using Multiplate (RocheAG; ADPtest, ASPItest, TRAPtest, COLtest) and MF using Oxygraph‐2k (Oroboros Instruments). The basal and maximum mitochondrial respiratory rate (MMRR) were determined. AA and MF were measured daily in I and II and AA in III and IV on d2 after TC/PTST. Statistical analysis was performed using tests for matched observations.
Results: Eleven PCs were used. TRAP‐6 induced AA was significantly lower in II when compared to I on d4 (P = 0.015*). In III the ASPItest was significantly lower (P = 0.032*). IV showed no significant differences. The basal and MMRR were significantly reduced over 4 days in I and II (for both rates in both groups: P = <0.0001*). No significant differences occurred on d4 (P = 0.495).
Conclusion: Our results indicate that ex vivo AA and MF of PCs are unaffected, even in no‐ideal storage and transport circumstances with respect to agitation, temperature, and force.
A central motivation for the development of x-ray free-electron lasers has been the prospect of time-resolved single-molecule imaging with atomic resolution. Here, we show that x-ray photoelectron diffraction—where a photoelectron emitted after x-ray absorption illuminates the molecular structure from within—can be used to image the increase of the internuclear distance during the x-ray-induced fragmentation of an O2 molecule. By measuring the molecular-frame photoelectron emission patterns for a two-photon sequential K-shell ionization in coincidence with the fragment ions, and by sorting the data as a function of the measured kinetic energy release, we can resolve the elongation of the molecular bond by approximately 1.2 a.u. within the duration of the x-ray pulse. The experiment paves the road toward time-resolved pump-probe photoelectron diffraction imaging at high-repetition-rate x-ray free-electron lasers.
The electron-capture process was studied for Xe54+ colliding with H2 molecules at the internal gas target of the Experimental Storage Ring (ESR) at GSI, Darmstadt. Cross-section values for electron capture into excited projectile states were deduced from the observed emission cross section of Lyman radiation, being emitted by the hydrogenlike ions subsequent to the capture of a target electron. The ion beam energy range was varied between 5.5 and 30.9 MeV/u by applying the deceleration mode of the ESR. Thus, electron-capture data were recorded at the intermediate and, in particular, the low-collision-energy regime, well below the beam energy necessary to produce bare xenon ions. The obtained data are found to be in reasonable qualitative agreement with theoretical approaches, while a commonly applied empirical formula significantly overestimates the experimental findings.