Refine
Year of publication
Document Type
- Preprint (428)
- Article (401)
- Conference Proceeding (1)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
Has Fulltext
- yes (832)
Is part of the Bibliography
- no (832)
Keywords
- e +-e − Experiments (13)
- BESIII (11)
- Hadron-Hadron Scattering (11)
- Branching fraction (9)
- Heavy Ion Experiments (8)
- Quarkonium (7)
- Particle and Resonance Production (6)
- Charm Physics (5)
- Jets (5)
- Collective Flow (4)
Institute
The neutron sensitivity of the C6D6 detector setup used at n_TOF facility for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a natC sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured natC yield has been discovered, which prevents the use of natC data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross-section measurements.
The neutron capture cross section of 58Ni was measured at the neutron time of flight facility n_TOF at CERN, from 27 meV to 400 keV neutron energy. Special care has been taken to identify all the possible sources of background, with the so-called neutron background obtained for the first time using high-precision GEANT4 simulations. The energy range up to 122 keV was treated as the resolved resonance region, where 51 resonances were identified and analyzed by a multilevel R-matrix code SAMMY. Above 122 keV the code SESH was used in analyzing the unresolved resonance region of the capture yield. Maxwellian averaged cross sections were calculated in the temperature range of kT = 5 – 100 keV, and their astrophysical implications were investigated.
An accurate quantification of low viremic HCV RNA plasma samples has gained importance since the approval of direct acting antivirals and since only one single measurement predicts the necessity of a prolonged or shortened therapy. As reported previously, HCV quantification assays such as Abbott RealTime HCV and Roche COBAS AmpliPrep/COBAS TaqMan HCV version 2 (CTM v2) may vary in sensitivity and precision particularly in low-level viremia. Importantly, substantial variations were previously demonstrated between some of these assays compared to the Roche High Pure System/COBAS TaqMan assay (HPS) reference assay, which was used to establish the clinical decision points in clinical studies. In this study, the reproducibility of assay performances across several laboratories was assessed by analysing quantification results generated by six independent laboratories (3× RealTime, 3× CTM v2) in comparison with one HPS reference laboratory. The 4th WHO Standard was diluted to 100, 25 and 10 IU/ml, and aliquots were tested in triplicates in 5 independent runs by each assay in the different laboratories to assess assay precision and detection rates. In a second approach, 2 clinical samples (GT 1a & GT 1b) were diluted to 100 and 25 IU/ml and tested as described above. While the result range for WHO 100 IU/ml replicates across all laboratories was similar in this analysis, the CVs of each laboratory ranged from 19.3 to 25.6 % for RealTime laboratories and were lower than CVs of CTM v2 laboratories with a range of 26.1–47.3 %, respectively, and also in comparison with the CV of the HPS reference laboratory (34.9 %). At WHO standard dilution of 25 IU/ml, 24 replicates were quantified by RealTime compared to 8 replicates with CTM v2. Results of clinical samples again revealed a higher variation of CTM v2 results as compared to RealTime values. (CVs at 100 IU/ml: RealTime: 13.1–21.0 % and CTM v2: 15.0–32.3 %; CVs at 25 IU/ml: RealTime 17.6–34.9 % and CTM v2 28.2–54.9 %). These findings confirm the superior precision of RealTime versus CTM v2 at low-level viremia even across different laboratories including the new clinical decision point at 25 IU/ml. A highly precise monitoring of HCV viral load during therapy will remain crucial for patient management with regard to futility rules, therapy efficacy and SVR.
Introduction Disseminated infection due to non-tuberculous mycobacteria has been a major factor of mortality and comorbidity in HIV patients. Until 2018, U.S. American guidelines have recommended antimycobacterial prophylaxis in patients with low CD4 cell counts, a practice that has not been adopted in Europe. This study aimed at examining the impact of disseminated NTM disease on clinical outcome in German HIV patients with a severe immunodeficiency. Materials and methods In this retrospective case control study, HIV patients with disseminated NTM disease were identified by retrospective chart review and matched by their CD4 cell counts to HIV patients without NTM infection in a 1:1 alocation. Primary endpoints were mortality and time to first rehospitalisation. In addition, other opportunistic diseases, as well as antimycobacterial and antiretroviral treatments were examined. Results Between 2006 and 2016, we identified 37 HIV patients with disseminated NTM disease. Most of them were suffering from infections due to M. avium complex (n = 31, 77.5%). Time to event analysis showed a non-significant trend to higher mortality in patients with disseminated NTM disease (p = 0.24). Rehospitalisation took place significantly earlier in patients with disseminated NTM infections (median 40.5 days vs. 109 days, p<0.0001). Conclusion In this retrospective case control study, we could demonstrate that mortality is not significantly higher in HIV patients with disseminated NTM disease in the ART era, but that they require specialised medical attention in the first months following discharge.
Poster presentation: Purpose of the study To compare the lipometabolic profiles of three double-boosted protease inhibitor (PI) regimens at standard dose, containing saquinavir and ritonavir in combination with lopinavir (LOPSAQ), atazanavir (ATSAQ) or fosamprenavir (FOSAQ) in HIV-positive patients, treated without reverse transcriptase inhibitors (RTI). ...
We present a study characterizing aerosol particles resulting from a skyscraper blasting. High mass concentrations with a maximum of 844.9 μg m-3 were present for a short time period of approximately 15 minutes. They result in a day mean of 32.6 μg m-3 compared to a 27.6 μg m-3 background not exceeding the 50 μg m-3 EU maximum permissive value. The increase in particle number concentration was less pronounced with a maximum concentration of 6.9 ⋅ 104 cm-3 compared to the local background value of 1.8 ⋅ 104 cm-3. The size-resolved number concentration shows a single mode of ultrafine particles at approximately 93 nm. The spatial distribution of deposited dust was investigated with Bergerhoff glass collection vessels, showing a decrease with distance. In the deposited dust samples the concentrations of twelve metals was determined, non of them exceeded the regional background concentrations significantly. The chemical composition of individual particles emitted by the demolition was studied by Scanning Electron Microscopy. They were mainly concrete and steel particles, with 60% calcium carbonates, 19% calcium sulfates, 19% silicates and 2% steel. In energy-dispersive X-Ray Spectroscopy, no fibers like asbestos were observed. Using a broad spectrum of instruments and methods, we obtain comprehensive characterization of the particles emitted by the demolition.
Background: Treatment of patients presenting with possible acute myocardial infarction (AMI) is based on timely diagnosis and proper risk stratification aided by biomarkers. We aimed at evaluating the predictive value of GDF-15 in patients presenting with symptoms suggestive of AMI.
Methods: Consecutive patients presenting with suspected AMI were enrolled in three study centers. Cardiovascular events were assessed during a follow-up period of 6 months with a combined endpoint of death or MI.
Results: From the 1818 enrolled patients (m/f = 1208/610), 413 (22.7%) had an acute MI and 63 patients reached the combined endpoint. Patients with MI and patients with adverse outcome had higher GDF-15 levels compared with non-MI patients (967.1pg/mL vs. 692.2 pg/L, p<0.001) and with event-free patients (1660 pg/mL vs. 756.6 pg/L, p<0.001). GDF-15 levels were lower in patients with SYNTAX score ≤ 22 (797.3 pg/mL vs. 947.2 pg/L, p = 0.036). Increased GDF-15 levels on admission were associated with a hazard ratio of 2.1 for death or MI (95%CI: 1.67–2.65, p<0.001) in a model adjusted for age and sex and of 1.57 (1.13–2.19, p = 0.008) adjusted for the GRACE score variables. GDF-15 showed a relevant reclassification with regards to the GRACE score with an overall net reclassification index (NRI) of 12.5% and an integrated discrimination improvement (IDI) of 14.56% (p = 0.006).
Conclusion: GDF-15 is an independent predictor of future cardiovascular events in patients presenting with suspected MI. GDF-15 levels correlate with the severity of CAD and can identify and risk-stratify patients who need coronary revascularization.
Hintergrund: Ab Frühjahr 2020 kam es zur weltweiten Verbreitung von SARS-CoV‑2 mit der heute als erste Welle der Pandemie bezeichneten Phase ab März 2020. Diese resultierte an vielen Kliniken in Umstrukturierungen und Ressourcenverschiebungen. Ziel unserer Arbeit war die Erfassung der Auswirkungen der Pandemie auf die universitäre Hals-Nasen-Ohren(HNO)-Heilkunde für die Forschung, Lehre und Weiterbildung. Material und Methoden: Die Direktorinnen und Direktoren der 39 Universitäts-HNO-Kliniken in Deutschland wurden mithilfe einer strukturierten Online-Befragung zu den Auswirkungen der Pandemie im Zeitraum von März bis April 2020 auf die Forschung, Lehre und die Weiterbildung befragt. Ergebnisse: Alle 39 Direktorinnen und Direktoren beteiligten sich an der Umfrage. Hiervon gaben 74,4 % (29/39) an, dass es zu einer Verschlechterung ihrer Forschungstätigkeit infolge der Pandemie gekommen sei. Von 61,5 % (24/39) wurde berichtet, dass pandemiebezogene Forschungsaspekte aufgegriffen wurden. Von allen Kliniken wurde eine Einschränkung der Präsenzlehre berichtet und 97,5 % (38/39) führten neue digitale Lehrformate ein. Im Beobachtungszeitraum sahen 74,4 % der Klinikdirektoren die Weiterbildung der Assistenten nicht gefährdet. Schlussfolgerung: Die Ergebnisse geben einen Einblick in die heterogenen Auswirkungen der Pandemie. Die kurzfristige Bearbeitung pandemiebezogener Forschungsthemen und die Einführung innovativer digitaler Konzepte für die studentische Lehre belegt eindrücklich das große innovative Potenzial und die schnelle Reaktionsfähigkeit der HNO-Universitätskliniken, um auch während der Pandemie ihre Aufgaben in der Forschung, Lehre und Weiterbildung bestmöglich zu erfüllen.
Poster presentation: Purpose of the study The aim of the Rainbow Cohort is to assess the tolerability and efficacy of initiating treatment with, or switching treatment to the saquinavir (SQV) 500 mg film-coated tablet formulation. We present the final 48-week subgroup analysis of PI-experienced, but SQV-naïve patients. ...