Filtern
Erscheinungsjahr
Dokumenttyp
- Wissenschaftlicher Artikel (32) (entfernen)
Sprache
- Englisch (32) (entfernen)
Volltext vorhanden
- ja (32)
Gehört zur Bibliographie
- nein (32)
Schlagworte
- SARS-CoV-2 (6)
- COVID-19 (5)
- PCR (4)
- antiviral therapy (3)
- ELISA (2)
- Medizinstudenten (2)
- PRNT (2)
- antiviral drugs (2)
- medical students (2)
- occupational infections (2)
Institut
- Medizin (32)
- Georg-Speyer-Haus (1)
In resource-limited or point-of-care settings, rapid diagnostic tests (RDTs), that aim to simultaneously detect HIV antibodies and p24 capsid (p24CA) antigen with high sensitivity, can pose important alternatives to screen for early infections. We evaluated the performance of the antibody and antigen components of the old and novel version of the Determine™ HIV-1/2 Ag/Ab Combo RDTs in parallel to quantifications in a fourth-generation antigen/antibody immunoassay (4G-EIA), p24CA antigen immunoassay (p24CA-EIA), immunoblots, and nucleic acid quantification. We included plasma samples of acute, treatment-naïve HIV-1 infections (Fiebig stages I–VI, subtypes A1, B, C, F, CRF02_AG, CRF02_AE, URF) or chronic HIV-1 and HIV-2 infections. The tests’ antigen component was evaluated also for a panel of subtype B HIV-1 transmitted/founder (T/F) viruses, HIV-2 strains and HIV-2 primary isolates. Furthermore, we assessed the analytical sensitivity of the RDTs to detect p24CA using a highly purified HIV-1NL4-3 p24CA standard. We found that 77% of plasma samples from acutely infected, immunoblot-negative HIV-1 patients in Fiebig stages II–III were identified by the new RDT, while only 25% scored positive in the old RDT. Both RDTs reacted to all samples from chronically HIV-1-infected and acutely HIV-1-infected patients with positive immunoblots. All specimens from chronically infected HIV-2 patients scored positive in the new RDT. Of note, the sensitivity of the RDTs to detect recombinant p24CA from a subtype B virus ranged between 50 and 200 pg/mL, mirrored also by the detection of HIV-1 T/F viruses only at antigen concentrations tenfold higher than suggested by the manufacturer. The RTD failed to recognize any of the HIV-2 viruses tested. Our results indicate that the new version of the Determine™ HIV-1/2 Ag/Ab Combo displays an increased sensitivity to detect HIV-1 p24CA-positive, immunoblot-negative plasma samples compared to the precursor version. The sensitivity of 4G-EIA and p24CA-EIA to detect the major structural HIV antigen, and thus to diagnose acute infections prior to seroconversion, is still superior.
Evaluation of stability and inactivation methods of SARS-CoV-2 in context of laboratory settings
(2021)
The novel coronavirus SARS-CoV-2 is the causative agent of the acute respiratory disease COVID-19, which has become a global concern due to its rapid spread. Laboratory work with SARS-CoV-2 in a laboratory setting was rated to biosafety level 3 (BSL-3) biocontainment level. However, certain research applications in particular in molecular biology require incomplete denaturation of the proteins, which might cause safety issues handling contaminated samples. In this study, we evaluated lysis buffers that are commonly used in molecular biological laboratories for their ability to inactivate SARS-CoV-2. In addition, viral stability in cell culture media at 4 °C and on display glass and plastic surfaces used in laboratory environment was analyzed. Furthermore, we evaluated chemical and non-chemical inactivation methods including heat inactivation, UV-C light, addition of ethanol, acetone-methanol, and PFA, which might be used as a subsequent inactivation step in the case of insufficient inactivation. We infected susceptible Caco-2 and Vero cells with pre-treated SARS-CoV-2 and determined the tissue culture infection dose 50 (TCID50) using crystal violet staining and microscopy. In addition, lysates of infected cells and virus containing supernatant were subjected to RT-qPCR analysis. We have found that guanidine thiocyanate and most of the tested detergent containing lysis buffers were effective in inactivation of SARS-CoV-2, however, the M-PER lysis buffer containing a proprietary detergent failed to inactivate the virus. In conclusion, careful evaluation of the used inactivation methods is required especially for non-denaturing buffers. Additional inactivation steps might be necessary before removal of lysed viral samples from BSL-3.
Medical students are exposed to infectious diseases during the course of their clinical training. Unfortunately, vaccination rates among medical students remain insufficient. However, immunizations against vaccine-preventable diseases should be carried out before the students enter clinical courses. This is vital in order to prevent nosocomial infections. We screened 366 medical students in their first clinical year for hospital-related viral diseases. Serum samples were collected between April and May 2007. Antibody testing was carried out using commercial ELISA systems against measles, mumps, rubella, varicella, hepatitis B (HBV), hepatitis C (HCV), and human immunodeficiency virus (HIV). Overall, 63.9% (n=234) of the students were sufficiently vaccinated against HBV. In contrast, 31.7% (n=116) had not received any HBV vaccine dosage, and 4.4% (n=16) had not completed the full vaccine cycle (<3 dosage). Remarkably, two students showed serological markers of resolved HBV infection. In addition, one student was HCV-positive and one was HIV-positive, respectively. The following seronegative rates were found: measles (7.9%), mumps (17.5%), rubella (6.5%), and varicella (2.2%). Further work is needed to identify optimal strategies for improving vaccination rates among medical students. It is imperative to identify and limit possible disparities in immunity of vaccine-preventable diseases before initial patient contact. With regard to the primary diagnosis of serious virus diseases including HBV, HCV and HIV, medical students should be screened for these blood borne pathogens.
Influenza A (H1N1) 2009 : impact on Frankfurt in due consideration of health care and public health
(2010)
Background: In April 2009 a novel influenza A H1N1/2009 virus was identified in Mexico and in the United States which quickly spread around the world. Most of the countries established infection surveillance systems in order to track the number of (laboratory-confirmed) H1N1 cases, hospitalizations and deaths. Methods: The impact of the emergence of the novel pandemic (H1N1) 2009 virus on Frankfurt was statistically evaluated by the Health Protection Authority, City of Frankfurt am Main. Vaccination rates of the health care workers (HCWs) of the University Hospital Frankfurt were measured by the Occupational Health Service. Results: Although the virulence of pandemic (H1N1) 2009 seems to be comparable with seasonal influenza, a major patient load and wave of hospital admissions occurred in the summer of 2009. Even though the 2009 vaccination rate of the University Hospital Frankfurt (seasonal influenza [40.5%], swine flu [36.3%]) is better than the average annual uptake of influenza vaccine in the German health care system (approximately 22% for seasonal and 15% for swine flu), vaccination levels remain insufficient. However, physicians were significantly (p < 0.001) more likely to have been vaccinated against swine flu and seasonal influenza than nurses. Conclusions: The outbreak of the pandemic (H1N1) 2009 in April 2009 provided a major challenge to health services around the world. Nosocomial transmission of H1N1/2009 has been documented. Present experience should be used to improve pandemic preparedness plans and vaccination programs ought to target as many HCWs as possible.
Introduction: Healthcare workers (HCWs) are exposed to bloodborne pathogens (e.g., contaminated devices). In the healthcare environment, needlestick injuries (NSI) represent a major risk factor in the transmission of hepatitis B virus (HBV), hepatitis C virus (HCV), and human immunodeficiency virus (HIV). Medical students are at risk of occupational exposure to bloodborne viruses following needlestick injuries during medical education. Reporting of needlestick injuries is an important step for initiating early prophylaxis or treatment. In the case of a bloodborne infection, pursuant to insure law could result in a claim. The objective of the present study was to describe occupational blood exposure of medical students through needlestick injuries.
Methods: Sixth-year medical students were invited to complete an anonymous questionnaire.
Results: In our study, 58.8% (n=183/311) of medical students recalled at least one needlestick injury during their studies. Overall, 284 needlestick injuries were reported. Only 38.3% of medical students reported all NSI to the appropriate hospital personnel. The main reason (54.0%) for not reporting NSI was being ashamed of having an NSI.
Conclusions: Occupational exposure to blood is a common problem among medical students. Efforts are required to ensure greater awareness among medical students about the risk of bloodborne pathogens. Proper training in procedures and how to act in case of injury should be offered to reduce the number of needlestick injuries.
Background Medical students come into contact with infectious diseases early on their career. Immunity against vaccine-preventable diseases is therefore vital for both medical students and the patients with whom they come into contact. Methods The purpose of this study was to compare the medical history and serological status of selected vaccine-preventable diseases of medical students in Germany. Results The overall correlation between medical history statements and serological findings among the 150 students studied was 86.7 %, 66.7 %, 78 % and 93.3 % for measles, mumps, rubella and varicella, conditional on sufficient immunity being achieved after one vaccination. Conclusions Although 81.2 % of the students medical history data correlated with serological findings, significant gaps in immunity were found. Our findings indicate that medical history alone is not a reliable screening tool for immunity against the vaccine-preventable diseases studied.
Purpose: Severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) replicates predominantly in the upper respiratory tract and is primarily transmitted by droplets and aerosols. Taking the medical history for typical COVID-19 symptoms and PCR-based SARS-CoV-2 testing have become established as screening procedures. The aim of this work was to describe the clinical appearance of SARS-CoV-2-PCR positive patients and to determine the SARS-CoV-2 contact risk for health care workers (HCW).
Methods: The retrospective study included n = 2283 SARS-CoV-2 PCR tests from n = 1725 patients with otorhinolaryngological (ORL) diseases performed from March to November 2020 prior to inpatient treatment. In addition, demographic data and medical history were assessed.
Results: n = 13 PCR tests (0.6%) were positive for SARS-CoV-2 RNA. The positive rate showed a significant increase during the observation period (p < 0.01). None of the patients had clinical symptoms that led to a suspected diagnosis of COVID-19 before PCR testing. The patients were either asymptomatic (n = 4) or had symptoms that were interpreted as symptoms typical of the ORL disease or secondary diagnoses (n = 9).
Conclusion: The identification of SARS-CoV-2-positive patients is a considerable challenge in clinical practice. Our findings illustrate that taking a medical history alone is of limited value and cannot replace molecular SARS-CoV-2 testing, especially for patients with ORL diseases. Our data also demonstrate that there is a high probability of contact with SARS-CoV-2-positive patients in everyday clinical practice, so that the use of personal protective equipment, even in apparently “routine cases”, is highly recommended.
The thrombopoietin receptor agonist eltrombopag was successfully used against human cytomegalovirus (HCMV)-associated thrombocytopenia refractory to immunomodulatory and antiviral drugs. These effects were ascribed to the effects of eltrombopag on megakaryocytes. Here, we tested whether eltrombopag may also exert direct antiviral effects. Therapeutic eltrombopag concentrations inhibited HCMV replication in human fibroblasts and adult mesenchymal stem cells infected with six different virus strains and drug-resistant clinical isolates. Eltrombopag also synergistically increased the anti-HCMV activity of the mainstay drug ganciclovir. Time-of-addition experiments suggested that eltrombopag interfered with HCMV replication after virus entry. Eltrombopag was effective in thrombopoietin receptor-negative cells, and the addition of Fe3+ prevented the anti-HCMV effects, indicating that it inhibits HCMV replication via iron chelation. This may be of particular interest for the treatment of cytopenias after hematopoietic stem cell transplantation, as HCMV reactivation is a major reason for transplantation failure. Since therapeutic eltrombopag concentrations are effective against drug-resistant viruses, and synergistically increase the effects of ganciclovir, eltrombopag is also a drug-repurposing candidate for the treatment of therapy-refractory HCMV diseas.
The demand to develop convergent technology platforms, such as bio-functionalized medical devices, is rapidly increasing. However, the loss of biological function of the effector molecules during sterilization represents a significant and general problem. Therefore, we have developed and characterized a nano-coating (NC) formulation capable of maintaining the functionality of proteins on biological-device combination products. As a proof of concept, the NC preserved the structural and functional integrity of an otherwise highly fragile antibody immobilized on polyurethane during deleterious sterilizing irradiation (≥ 25 kGy). The NC procedure enables straight-forward terminal sterilization of bio-functionalized materials while preserving optimal conditioning of the bioactive surface.
Background: Hundreds of West African healthcare workers (HCW) have become ill with Ebola virus disease (EVD) and died during the recent outbreak. The occurrence of occupational infections in laboratories could be due to the lack of use of personal protective equipment, the failure to implement specific regulations about the use of equipment and how to work with hazardous materials. Our study attempted to assess the information as well as training level of HCW of a German high level isolation unit and their concern over an occupationally acquired EVD.
Methods: During the recent Ebola virus outbreak a survey was conducted among HCWs, using an anonymous questionnaire.
Results: Although 70% of our total study population stated that they have all the information needed to care for Ebola patients, only 18.2% of laboratory workers and 29.4% of the HCW of the virology department felt sufficiently trained. The HCW rated the Internet (64.3%) and the daily press (54.3%) as the most important sources of information. Medical literature (45.7%) and official institutions (40.4%) were rated less often.
Conclusions: Formulated pointedly, the HCW turned to popular science to get the information they need to feel safe. Further in house training regarding practical skills and reference to scientific literature would be a better solution to ensure workplace safety.