Refine
Year of publication
- 2021 (2) (remove)
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- Acuris (1)
- CAD/ CAM crown (1)
- COVID-19 (1)
- Germany (1)
- bacterial leakage (1)
- conical coupling (1)
- conometric connection (1)
- healthcare systems (1)
- inpatient hospital admissions (1)
- lockdown (1)
Institute
- Medizin (2)
The COVID-19 pandemic has caused strains on health systems worldwide disrupting routine hospital services for all non-COVID patients. Within this retrospective study, we analyzed inpatient hospital admissions across 18 German university hospitals during the 2020 lockdown period compared to 2018. Patients admitted to hospital between January 1 and May 31, 2020 and the corresponding periods in 2018 and 2019 were included in this study. Data derived from electronic health records were collected and analyzed using the data integration center infrastructure implemented in the university hospitals that are part of the four consortia funded by the German Medical Informatics Initiative. Admissions were grouped and counted by ICD 10 chapters and specific reasons for treatment at each site. Pooled aggregated data were centrally analyzed with descriptive statistics to compare absolute and relative differences between time periods of different years. The results illustrate how care process adoptions depended on the COVID-19 epidemiological situation and the criticality of the disease. Overall inpatient hospital admissions decreased by 35% in weeks 1 to 4 and by 30.3% in weeks 5 to 8 after the lockdown announcement compared to 2018. Even hospital admissions for critical care conditions such as malignant cancer treatments were reduced. We also noted a high reduction of emergency admissions such as myocardial infarction (38.7%), whereas the reduction in stroke admissions was smaller (19.6%). In contrast, we observed a considerable reduction in admissions for non-critical clinical situations, such as hysterectomies for benign tumors (78.8%) and hip replacements due to arthrosis (82.4%). In summary, our study shows that the university hospital admission rates in Germany were substantially reduced following the national COVID-19 lockdown. These included critical care or emergency conditions in which deferral is expected to impair clinical outcomes. Future studies are needed to delineate how appropriate medical care of critically ill patients can be maintained during a pandemic.
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.