Refine
Year of publication
Document Type
- Article (19)
- Preprint (4)
- Working Paper (1)
Has Fulltext
- yes (24)
Is part of the Bibliography
- no (24)
Keywords
- ACL (1)
- Acuris (1)
- Aufsatzsammlung (1)
- Bidirectional genes (1)
- CAD/ CAM crown (1)
- COVID-19 (1)
- Chemotherapy (1)
- Epigenetics (1)
- FX06 (1)
- Functional outcome (1)
Institute
- Physik (10)
- Medizin (9)
- Biochemie und Chemie (1)
- Biodiversität und Klima Forschungszentrum (BiK-F) (1)
- Institut für Ökologie, Evolution und Diversität (1)
- Sportwissenschaften (1)
- Starker Start ins Studium: Qualitätspakt Lehre (1)
- Zentrum für Arzneimittelforschung, Entwicklung und Sicherheit (ZAFES) (1)
- Zentrum für Nordamerika-Forschung (ZENAF) (1)
Background: Although anterior cruciate ligament (ACL) tear-prevention programs may be effective in the (secondary) prevention of a subsequent ACL injury, little is known, yet, on their effectiveness and feasibility. This study assesses the effects and implementation capacity of a secondary preventive motor-control training (the Stop-X program) after ACL reconstruction.
Methods and design: A multicenter, single-blind, randomized controlled, prospective, superiority, two-arm design is adopted. Subsequent patients (18–35 years) with primary arthroscopic unilateral ACL reconstruction with autologous hamstring graft are enrolled. Postoperative guideline rehabilitation plus Classic follow-up treatment and guideline rehabilitation plus the Stop-X intervention will be compared. The onset of the Stop-X program as part of the postoperative follow-up treatment is individualized and function based. The participants must be released for the training components. The endpoint is the unrestricted return to sport (RTS) decision. Before (where applicable) reconstruction and after the clearance for the intervention (aimed at 4–8 months post surgery) until the unrestricted RTS decision (but at least until 12 months post surgery), all outcomes will be assessed once a month. Each participant is consequently measured at least five times to a maximum of 12 times. Twelve, 18 and 24 months after the surgery, follow-up-measurements and recurrence monitoring will follow. The primary outcome assessement (normalized knee-separation distance at the Drop Jump Screening Test (DJST)) is followed by the functional secondary outcomes assessements. The latter consist of quality assessments during simple (combined) balance side, balance front and single-leg hops for distance. All hop/jump tests are self-administered and filmed from the frontal view (3-m distance). All videos are transferred using safe big content transfer and subsequently (and blinded) expertly video-rated. Secondary outcomes are questionnaires on patient-reported knee function, kinesiophobia, RTS after ACL injury and training/therapy volume (frequency – intensity – type and time). All questionnaires are completed online using the participants’ pseudonym only.
Group allocation is executed randomly. The training intervention (Stop-X arm) consists of self-administered home-based exercises. The exercises are step-wise graduated and follow wound healing and functional restoration criteria. The training frequency for both arms is scheduled to be three times per week, each time for a 30 min duration. The program follows current (secondary) prevention guidelines.
Repeated measurements gain-score analyses using analyses of (co-)variance are performed for all outcomes.
Trial registration: German Clinical Trials Register, identification number DRKS00015313. Registered on 1 October 2018.
Consensus on definition and severity grading of lymphatic complications after kidney transplantation
(2020)
Background: The incidence of lymphatic complications after kidney transplantation varies considerably in the literature. This is partly because a universally accepted definition has not been established. This study aimed to propose an acceptable definition and severity grading system for lymphatic complications based on their management strategy.
Methods: Relevant literature published in MEDLINE and Web of Science was searched systematically. A consensus for definition and a severity grading was then sought between 20 high-volume transplant centres.
Results: Lymphorrhoea/lymphocele was defined in 32 of 87 included studies. Sixty-three articles explained how lymphatic complications were managed, but none graded their severity. The proposed definition of lymphorrhoea was leakage of more than 50 ml fluid (not urine, blood or pus) per day from the drain, or the drain site after removal of the drain, for more than 1 week after kidney transplantation. The proposed definition of lymphocele was a fluid collection of any size near to the transplanted kidney, after urinoma, haematoma and abscess have been excluded. Grade A lymphatic complications have a minor and/or non-invasive impact on the clinical management of the patient; grade B complications require non-surgical intervention; and grade C complications require invasive surgical intervention.
Conclusion: A clear definition and severity grading for lymphatic complications after kidney transplantation was agreed. The proposed definitions should allow better comparisons between studies.
The COVID-19 pandemic has caused strains on health systems worldwide disrupting routine hospital services for all non-COVID patients. Within this retrospective study, we analyzed inpatient hospital admissions across 18 German university hospitals during the 2020 lockdown period compared to 2018. Patients admitted to hospital between January 1 and May 31, 2020 and the corresponding periods in 2018 and 2019 were included in this study. Data derived from electronic health records were collected and analyzed using the data integration center infrastructure implemented in the university hospitals that are part of the four consortia funded by the German Medical Informatics Initiative. Admissions were grouped and counted by ICD 10 chapters and specific reasons for treatment at each site. Pooled aggregated data were centrally analyzed with descriptive statistics to compare absolute and relative differences between time periods of different years. The results illustrate how care process adoptions depended on the COVID-19 epidemiological situation and the criticality of the disease. Overall inpatient hospital admissions decreased by 35% in weeks 1 to 4 and by 30.3% in weeks 5 to 8 after the lockdown announcement compared to 2018. Even hospital admissions for critical care conditions such as malignant cancer treatments were reduced. We also noted a high reduction of emergency admissions such as myocardial infarction (38.7%), whereas the reduction in stroke admissions was smaller (19.6%). In contrast, we observed a considerable reduction in admissions for non-critical clinical situations, such as hysterectomies for benign tumors (78.8%) and hip replacements due to arthrosis (82.4%). In summary, our study shows that the university hospital admission rates in Germany were substantially reduced following the national COVID-19 lockdown. These included critical care or emergency conditions in which deferral is expected to impair clinical outcomes. Future studies are needed to delineate how appropriate medical care of critically ill patients can be maintained during a pandemic.
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.