Aims: Understanding the orientation of fracture lines and mechanisms is the essential key to sufficient surgical therapy, but there is still a lack of visualization and teaching methods in traumatology and fracture theory. 3D-printed models offer easy approach to those fractures. This paper explains the use of the teaching possibility with 3-dimensional models of transitional fractures of the ankle.
Methods and results: For generating 3D printable models, already obtained CT data were used and segmented into its different tissues, especially parts concerning the fracture. After the segmentation process, the models were produced with FFF (fused filament fabrication) printing technology. The fracture models then were used for hands-on teaching courses in AO course (Arbeitsgemeinschaft für Osteosynthesefragen) of pediatric traumatology in 2020 in Frankfurt. In the course fracture anatomy with typical fracture lines, approaches, and screw placement could be shown, discussed and practiced.
Conclusion: The study shows the use of 3D-printed teaching models and helps to understand complicated fractures, in this case, transitional fractures of the ankle. The teaching method can be adapted to numerous other use cases.
Background: Surgical complications are associated with a significant burden to patients and hospitals and are increasingly discussed in recent literature. This cohort study reviewed surgery-related complications in a Level I trauma center. The effect of a complication avoidance care bundle on the rate of surgical complications was analyzed. Methods: All complications (surgical and nonsurgical) that occur in our trauma department are prospectively captured using a standardized documentation form and are discussed and analyzed in a weekly trauma Morbidity and Mortality (M&M) conference. Surgical complication rates are calculated using the annual surgical procedure numbers. Based on discussions in the M&M conference, a complication avoidance care bundle consisting of five measures was established: (1) Improving team situational awareness; (2) reducing operating room traffic by staff members and limiting door-opening events; (3) preoperative screening for infectious foci; (4) adapted preoperative antibiotic prophylaxis in anatomic regions with a high risk of infectious complications; and (5) use of iodine-impregnated adhesive drape. Results: The number of surgical procedures steadily increased over the study years, from 3587 in 2015 to 3962 in 2019 (an increase of 10.5%). Within this 5-year study period, the overall rate of surgical complications was 0.8%. Surgical site infections were the most frequently found complications (n = 40, 24.8% of all surgical complications), followed by screw malposition (n = 20, 12.4%), postoperative dislocations of arthroplasties (n = 18, 11.2%), and suboptimal fracture reduction (n = 18, 11.2%). Following implementation of the complication avoidance care bundle, the overall rate of surgical complications significantly decreased, from 1.14% in the year 2016 to 0.56% in the study year 2019, which represents a reduction of 51% within a 3-year time period. Conclusions: A multimodal strategy targeted at reducing the surgical complication rate can be successfully established based on a transparent discussion of adverse surgical outcomes. The combination of the different preventive measures was associated with reducing the overall complication rate by half within a 3-year time period.
Background: Lectures remain an important teaching method to present and structure knowledge to many students concurrently. Adequate measures are necessary to maintain the quality of the lectures. The aim of this study was to determine the impact on the lecture quality using written structured feedback and to compare the ratings of surgical lectures between students and surgical peers.
Methods: Prospective analysis of two consecutive surgical lecture series for undergraduate students at Goethe-University Medical School was performed before and after evaluation of the lecturers via independent written feedback from trained undergraduate students and surgeons. The 22-item feedback instrument covered three areas of performance: content, visualization, and delivery. Additional suggestions for improvement were provided from
both students and surgical peers who anonymously attended the lectures. The lecturers, experienced surgeons, as well as the student and peer raters were blinded in terms of the aim and content of the study. Their response to the feedback was collected using a web-based 13-item questionnaire. The Kendall’s-W coefficient was computed to calculate inter-rater reliability (IRR). Differences between ratings before and after feedback were analyzed using Student’s t-test for dependent samples. The Kolmogorov-Smirnov-test was used for independent samples.
Results: A total of 22 lectures from a possible 32 given by 13 lecturers were included and analyzed by at least three surgeons and two students. There were significant improvements in overall score as well as in the details of 9 of the 13 items were found. The average inter-rater reliability was 0.71. There were no differences in the ratings as a function of the rater’s level of expertise (peers vs. students). We found that 13/23 lecturers (56.5%) answered the questionnaire, and 92% strongly agreed that the written feedback was useful. 76.9% of the lecturers revised their lecture based on the written feedback requiring on average 112.5 min (range from 20 to 300 min).
Conclusions: Overall, this study indicates that structured written feedback provided by trained peers and students that is subsequently discussed by the lecturers concerned is a highly effective and efficient method to improve aspects of lecturing. We anticipate that structured written feedback by trained students that is discussed by the lecturers concerned will improve lecturing.
Keywords: Lecture, Feedback, Surgery, Peer-feedback, Evaluation, Undergraduate training
Introduction: In patients with severe pelvic ring injuries, exsanguination still is the leading cause of death in the early post-injury phase. While mechanical pelvic ring stabilization and pre-peritoneal pelvic packing are mainly addressing venous bleeding, angio-embolization aims to control arterial bleeding. The goal of the present study was to evaluate the rate of postoperative angio-embolization after mechanical pelvic ring injury stabilization and pre-peritoneal pelvic packing. Bleeding sources detected in the angiography and the patient's outcome were investigated. Patients and Methods: Retrospective observational cohort study at a single academic level I trauma center, reviewing all patients with pelvic ring injuries admitted from 01/2010 to 12/2019. Patients with emergent mechanical pelvic ring stabilization (supraacetabular external fixator and/or pelvic C-clamp) and direct pre-peritoneal pelvic packing were further analyzed. Patients that underwent postoperative angio-embolization were compared with those that did not. All postoperative angio-embolizations were evaluated with regards to bleeding sources and type of embolization. Results: During the study period, a total of 39 patients required immediate mechanical pelvic stabilization and direct pre-peritoneal pelvic packing. Of these, 12 patients (30.8%) underwent a postoperative angio-embolization. The following vessels were identified as bleeding sources: superior gluteal artery (n = 6), obturator artery (n = 2), internal pudendal artery (n = 2), unnamed branches of the internal iliac artery (n = 3). A selective embolization was successful in 11 patients; in 1 patient, an unilateral complete occlusion of the internal iliac artery was performed to control the bleeding. Mean time from hospital admission to the surgical procedure was 52.8 ± 14.7 min and the mean time from admission to angio-embolization was 189.1 ± 55.5 min. The in-hospital mortality rate of patients with angio-embolization was 25.0% (n = 3). Of these, 2 patients died due to multiple organ failure and 1 patient due to severe head injury. Conclusion: Secondary angio-embolization after external pelvic fixation and pre-peritoneal pelvic packing was effective in controlling ongoing bleeding. The most frequently detected bleeding vessel was the superior gluteal artery, which is difficult to surgically address, further highlighting the importance of angio-embolization in the management algorithm.
Introduction: The aim of this article is to show a new concept of indication and application of the MUTARS® RS Cup System in primary and revision hip arthroplasty. This integrated system is applicable for different acetabular cup replacements in patients with acetabular fractures or instable defects, as well as periprosthetic acetabular fractures. The MUTARS® RS Cup System is a cementless revision cup for insertion into the acetabulum with an integrated polyethylene cup, which fits to a regular or bipolar head. This system replaces the conventional approach for acetabular revision with a Burch-Schneider ring, in which a normal polyethylene cup is cemented. This interface with its complications is avoided with this system of a titanium revision cup with integrated polyethylene cup. Steps of preoperative planning and the intraoperative implementation will be highlighted in this article.
Material and methods: This system was applied in 49 patients with 52 MUTARS® RS Cup Implantations in 30 males, 22 females, with an average age of 76,1 years (36,9–94,4 years).
Results and discussion: The system shows a good operative feasibility, as well as a reliable handling and safe method for stable treatment of non-reconstructable acetabular fractures or acetabular incongruencies and instabilities.
Objective: Skin and soft tissue infections (SSTI) are a commonly known entity of diseases associated with difficult treatment procedures. The current gold standard when there is a rapidly progressing infection of soft tissues with a risk of sepsis is radical surgical debridement accompanied by systemic antibiotic therapy. In clinical settings, local antibiotics alone or formulated within carrier material are commonly used alongside this therapy regimen. One possibility of local antibiotic application is the fixation of colistin with fibrin glue spray. It is not yet sufficiently researched how the local antibiotic concentrations remain as high as possible over time.
Methods: We conducted an animal study including 29 male Wistar rats inducing sterile back sores reaching the muscle fascia. We sprayed only colistin, simultaneously or consecutively, with fibrin glue in different groups in order to measure the tissue concentration of the antibiotic applied locally.
Results: After liquid chromatography and quadrupole mass spectrometry analysis, it could be demonstrated that in comparison to the colistin group, tissue concentrations of colistin stayed significantly higher in the wound tissue when it was fixed with fibrin glue. This was observed in both groups, the simultaneous as well as in the consecutively fibrin glue sprayed groups after colistin application.
Conclusion: The fixation of colistin with the fibrin-glue-spray technique as a carrier for local antibiotic therapy is an easy and inexpensive method and shows promising potential for the treatment of SSTI.
The Masquelet technique for the treatment of large bone defects is a two-stage procedure based on an induced membrane. We eliminate the first surgical step by using a decellularized dermal skin graft (Epiflex®) populated with bone marrow mononuclear cells (BMC), as a replacement for the induced membrane. The aim of this study was to demonstrate the feasibility of this technology and provide evidence of equivalent bone healing in comparison to the induced membrane-technique. Therefore, 112 male Sprague–Dawley rats were allocated in six groups and received a 10 mm femoral defect. Defects were treated with either the induced membrane or decellularized dermis, with or without the addition of BMC. Defects were then filled with a scaffold (β-TCP), with or without BMC. After a healing time of eight weeks, femurs were taken for histological, radiological and biomechanical analysis. Defects treated with Epiflex® showed increased mineralization and bone formation predominantly in the transplanted dermis surrounding the defect. No significant decrease of biomechanical properties was found. Vascularization of the defect could be enhanced by addition of BMC. Considering the dramatic reduction of a patient’s burden by the reduced surgical stress and shortened time of treatment, this technique could have a great impact on clinical practice.
Introduction: The induced membrane technique for the treatment of large bone defects is a two-step procedure. In the first operation, a foreign body membrane is induced around a spacer, then, in the second step, several weeks or months later, the spacer is removed and the Membrane pocket is filled with autologous bone material. Induction of a functional biological membrane might be avoided by initially using a biological membrane. In this study, the effect of a human acellular dermis (hADM, Epiflex, DIZG gGmbH) was evaluated for the treatment of a large (5 mm), plate-stabilised femoral bone defect.
Material and Methods: In an established rat model, hADM was compared to the two-stage induced membrane technique and a bone defect without membrane cover. Syngeneous spongiosa from donor animals was used for defect filling in all groups. The group size in each case was n = 5, the induction time of the membrane was 3–4 weeks and the healing time after filling of the defect was 8 weeks.
Results: The ultimate loads were increased to levels comparable with native bone in both membrane groups (hADM: 63.2% ± 29.6% of the reference bone, p < 0.05 vs. no membrane, induced membrane: 52.1% ± 25.8% of the reference bone, p < 0.05 vs. no membrane) and were significantly higher than the control group without membrane (21.5%). The membrane groups were radiologically and histologically almost completely bridged by new bone formation, in contrast to the control Group where no closed osseous bridging could be observed.
Conclusion: The use of the human acellular dermis leads to equivalent healing results in comparison to the two-stage induced membrane technique. This could lead to a shortened therapy duration of large bone defects.
Introduction: Microsurgery courses, taught external to surgical training programs, are essential for acquiring the high level of technical skill required for clinical proficiency.
Methods: The Frankfurt microsurgery course is a 5-day, intensive course that teaches arterial and venous anastomosis using end-to-end, end-to-side, one-way-up, continuous-suture, and vessel graft techniques. During the course, the instructor records the level of skill (in-course data) achieved by each trainee by assessing anastomosis completion and patency. Demographic information is also collected. Post-course trainees are invited to complete an online survey (post-course data) to get their opinions of the courses’ effectiveness.
Results: The in-course “skill achievement” and post-course “course effectiveness” data are presented below. In-course data: 94.8 and 59.9% of participants completed patent end-to-end arterial and venous anastomoses, respectively, while 85.4% performed a patent end-to-side anastomosis. 96.1 and 57.1% of participants who attempted arterial and venous anastomoses using the one-way-up technique were successful, as were 90.9% of those attempting continuous-suture technique. Patent venous grafts were performed by 54.7% of participants.
Post-course data: All respondents indicated significant improvement of their microsurgical skills after taking the course. 66.7% of respondents considered the full-time presence of the instructor to be the most valuable aspect of the course. All respondents would highly recommend the course to colleagues.
Conclusion: The microcourse significantly increased trainees’ clinical microsurgery skills, confidence, and the number of clinical cases they perform. Of all the anastomosis techniques taught, venous anastomosis and grafting were the most difficult to learn. The presence of a full-time experienced instructor was most important.
Treatment of large bone defects is one of the great challenges in contemporary orthopedic and traumatic surgery. Grafts are necessary to support bone healing. A well-established allograft is demineralized bone matrix (DBM) prepared from donated human bone tissue. In this study, a fibrous demineralized bone matrix (f-DBM) with a high surface-to-volume ratio has been analyzed for toxicity and immunogenicity. f-DBM was transplanted to a 5-mm, plate-stabilized, femoral critical-size-bone-defect in Sprague-Dawley (SD)-rats. Healthy animals were used as controls. After two months histology, hematological analyses, immunogenicity as well as serum biochemistry were performed. Evaluation of free radical release and hematological and biochemical analyses showed no significant differences between the control group and recipients of f-DBM. Histologically, there was no evidence of damage to liver and kidney and good bone healing was observed in the f-DBM group. Reactivity against human HLA class I and class II antigens was detected with mostly low fluorescence values both in the serum of untreated and treated animals, reflecting rather a background reaction. Taken together, these results provide evidence for no systemic toxicity and the first proof of no basic immunogenic reaction to bone allograft and no sensitization of the recipient.