Refine
Year of publication
- 2011 (6) (remove)
Document Type
- Article (4)
- Conference Proceeding (2)
Language
- English (6) (remove)
Has Fulltext
- yes (6)
Is part of the Bibliography
- no (6)
Institute
- Physik (3)
- Medizin (2)
- Frankfurt Institute for Advanced Studies (FIAS) (1)
- Geowissenschaften (1)
- Informatik (1)
Rapidity and transverse momentum dependence of inclusive J/ψ production in pp collisions at √s=7 TeV
(2011)
The ALICE experiment at the LHC has studied inclusive J/ψ production at central and forward rapidities in pp collisions at √s=7 TeV. In this Letter, we report on the first results obtained detecting the J/ψ through the dilepton decay into e+e− and μ+μ− pairs in the rapidity ranges |y|<0.9 and 2.5<y<4, respectively, and with acceptance down to zero pT. In the dielectron channel the analysis was carried out on a data sample corresponding to an integrated luminosity Lint=5.6 nb−1 and the number of signal events is NJ/ψ=352±32(stat.)±28(syst.); the corresponding figures in the dimuon channel are Lint=15.6 nb−1 and NJ/ψ=1924±77(stat.)±144(syst.). The measured production cross sections are σJ/ψ(|y|<0.9)=10.7±1.0(stat.)±1.6(syst.)−2.3+1.6(syst.pol.)μb and σJ/ψ(2.5<y<4)=6.31±0.25(stat.)±0.76(syst.)−1.96+0.95(syst.pol.)μb. The differential cross sections, in transverse momentum and rapidity, of the J/ψ were also measured.
Introduction: Evidence from a number of open-label, uncontrolled studies has suggested that rituximab may benefit patients with autoimmune diseases who are refractory to standard-of-care. The objective of this study was to evaluate the safety and clinical outcomes of rituximab in several standard-of-care-refractory autoimmune diseases (within rheumatology, nephrology, dermatology and neurology) other than rheumatoid arthritis or non-Hodgkin's lymphoma in a real-life clinical setting.
Methods: Patients who received rituximab having shown an inadequate response to standard-of-care had their safety and clinical outcomes data retrospectively analysed as part of the German Registry of Autoimmune Diseases. The main outcome measures were safety and clinical response, as judged at the discretion of the investigators.
Results: A total of 370 patients (299 patient-years) with various autoimmune diseases (23.0% with systemic lupus erythematosus, 15.7% antineutrophil cytoplasmic antibody-associated granulomatous vasculitides, 15.1% multiple sclerosis and 10.0% pemphigus) from 42 centres received a mean dose of 2,440 mg of rituximab over a median (range) of 194 (180 to 1,407) days. The overall rate of serious infections was 5.3 per 100 patient-years during rituximab therapy. Opportunistic infections were infrequent across the whole study population, and mostly occurred in patients with systemic lupus erythematosus. There were 11 deaths (3.0% of patients) after rituximab treatment (mean 11.6 months after first infusion, range 0.8 to 31.3 months), with most of the deaths caused by infections. Overall (n = 293), 13.3% of patients showed no response, 45.1% showed a partial response and 41.6% showed a complete response. Responses were also reflected by reduced use of glucocorticoids and various immunosuppressives during rituximab therapy and follow-up compared with before rituximab. Rituximab generally had a positive effect on patient well-being (physician's visual analogue scale; mean improvement from baseline of 12.1 mm).
Conclusions: Data from this registry indicate that rituximab is a commonly employed, well-tolerated therapy with potential beneficial effects in standard of care-refractory autoimmune diseases, and support the results from other open-label, uncontrolled studies.
Introduction: As the immunosuppressive potency of 15-deoxyspergualin (DSG) has been shown in the therapy of renal transplant rejection and Wegener's granulomatosis, the intention of this study was to evaluate the safety of DSG in the therapy of lupus nephritis (LN). Methods: Patients with histologically proven active LN after prior treatment with at least one immunosuppressant were treated with 0.5 mg/kg normal body weight/day DSG, injected subcutaneously for 14 days, followed by a break of one week. These cycles were repeated to a maximum of 9 times. Doses of oral corticosteroids were gradually reduced to 7.5 mg/day or lower by cycle 4. Response was measured according to a predefined decision pattern. The dose of DSG was adjusted depending on the efficacy and side effects. Results: 21 patients were included in this phase-I/II study. After the first DSG injection, one patient was excluded from the study due to renal failure. 5 patients dropped out due to adverse events or serious adverse events including fever, leukopenia, oral candidiasis, herpes zoster or pneumonia. 11/20 patients achieved partial (4) or complete responses (7), 8 were judged as treatment failures and one patient was not assessable. 12 patients completed all 9 cycles; in those patients, proteinuria decreased from 5.88g/day to 3.37g/day (P = 0.028), Selena-SLEDAI decreased from 17.6 to 11.7. In 13/20 patients, proteinuria decreased by at least 50%; in 7 patients to less than 1g/day. Conclusions: Although the number of patients was small, we could demonstrate that DSG provides a tolerably safe treatment for LN. The improvement in proteinuria encourages larger controlled trials.
Chopper systems are used to pulse charged particle beams. In most cases, electric deflection systems are used to generate beam pulses of defined lengths and appropriate repetition rates. At high beam intensities, the field distribution of the chopper system needs to be adapted precisely to the beam dynamics in order to avoid aberrations. An additional challenge is a robust design which guarantees reliable operation. For the Frankfurt Neutron Source FRANZ, an E×B chopper system is being developed which combines static magnetic deflection with a pulsed electric field in a Wien filter configuration. It will generate proton pulses with a flat top of 50 ns at a repetition rate of 250 kHz for 120 keV, 200 mA beams. For the electric deflection, pre-experiments with static and pulsed fields were performed using a helium ion beam. In pulsed mode operation, ion beams of different energies were deflected with voltages of up to ±6 kV and the resulting response was measured using a beam current transformer. A comparison between experiments and theoretical calculations as well as numerical simulations are presented.
This novel kind of neutron beam facility will provide 1 ns short neutron pulses with an approximately thermal energy distribution around 30 keV. The pulse repetition rate will be up to 250 kHz, the total proton number per pulse will be up to 6×1010 in the final stage, starting with a p – source current of 200 mA. A second target station will allow n – activation experiments by cw beam operation. An intense 2 MeV proton beam will drive a neutron source by the 7 Li (p,n) 7 Be reaction. The facility is under construction at the physics experimental hall of the J.W. Goethe – University. The 1m thick concrete tunnel was installed in 2009. In 2011 all rf amplifiers will be delivered and installed. Successful 200 mA proton source experiments in 2010 at a test stand will be followed by experiments on the 120 kV FRANZ terminal in 2011. The 250 kHz, 100 ns chopper in front of the rf linac is under construction, while the 2 MeV bunch compressor design was finished and the technical design of all components has started. The main accelerator cavity is under construction. First 2 MeV beam tests are expected for end of 2012.
Explosive volcanism affects weather and climate. Primary volcanic ash particles which act as ice nuclei (IN) can modify the phase and properties of cold tropospheric clouds. During the Eyjafjallajökull volcanic eruption we have measured the highest ice nucleus number concentrations (>600 L) in our record of 2 years of daily IN measurements in central Germany. Even in Israel, located about 5000 km away from Iceland, IN were as high as otherwise only during desert dust storms. These measurements are the only ones available on the properties of IN in the Eyjafjallajökull plume. The measured high concentrations and high activation temperature (−8 °C) point to an important impact of volcanic ash on microphysical and radiative properties of clouds through enhanced glaciation.