Refine
Year of publication
- 2010 (1) (remove)
Document Type
- Doctoral Thesis (1)
Language
- English (1)
Has Fulltext
- yes (1)
Is part of the Bibliography
- no (1)
Institute
- Medizin (1)
Aim: To study the changes in leiomyoma volume following uterine artery embolization (UAE) and to correlate these changes with the initial leiomyoma volume and location within the uterus and to evaluate the impact of preprocedural prediction of the best tube angle obliquity for visualization of the uterine artery origin using 3D-reconstructed contrast-enhanced MR angiography (CE-MRA) on the radiation dose, fluoroscopy time and contrast medium volume used during UAE. Materials and Methods: The study was performed in two parts. The first part was retrospectively done on 28 patients (age range: 37-57 years, mean: 48 years, SD: 4.81) in whom UAE was performed. All leiomyomas in all patients were evaluated. In total, 84 leiomyomas were evaluated. MRI studies were performed before, 3 months and 1 year after UAE. The volumes and location of each leiomyoma in each patient were evaluated in consensus by two radiologists. The second part included 40 consecutive patients (age range: 37-56 years, mean: 46 years, SD: 4.49) and was done in a controlled prospective/retrospective manner. In 20 sample patients (prospective part) pre-procedural prediction of the best tube angle obliquity was predicted using 3D-reconstructed CE-MRA and provided to the interventionalist. 3D-reconstruction was done using Inspace application. The radiation dose, fluoroscopy time and contrast medium volume for those patients were compared with the data of the last 20 procedures (control) performed by the same interventionalist (retrospective part). Results: For the first part the mean pre-embolization volume was 51.6 cm3 range:0.72-371.1cm3, SD=79.3). At 3-month follow-up 83 (98.8%) leiomyomas showed a mean volume reduction of 52.62% (range: 12.79–96.67%, SD=21.85) and 1 leiomyoma (1.2%) increased in volume. At 1-year follow-up 5 (6%) leiomyomas were not detectable, 72 (85.7%) showed a further mean of 20.5% (range: 2.52–58.72%, SD=11.92) volume reduction compared to the 3-month follow-up volume and 7 (8.3%) leiomyomas increased in volume. A statistically significant (p=0.026 at 3-month, p=0.0046 at 1-year) difference in percentage of volume change was observed based on leiomyoma location; submucous leiomyomas showed the largest volume reduction. The initial leiomyoma volume showed a weak negative correlation (Spearman's correlation-coefficient =-0.35 at 3m and -0.36 at 1y) with the leiomyoma volume change. For the second part the tube angle prediction resulted in a significant reduction of the radiation dose utilized (p<0.001), fluoroscopy time (p=0.002) and contrast medium volume (p<0.001) for the sample patients when compared with the control patients. The overall radiation dose was reduced from a mean of 11044 μGym2 to a mean of 4172.5 μGym2, fluoroscopy time was reduced from a mean of 15.45 minutes to 8.81 minutes and contrast medium volume was reduced from a mean of 135 ml to 75 ml. Conclusion: UAE results in significant leiomyoma volume reduction at 3-month and 1- year follow-up. The leiomyoma location plays an important role in volume changes while the initial leiomyoma volume plays a minor role. Pre-procedural prediction of the best tube angle obliquity for visualization of the origin of the uterine artery using 3D-reconstructed CE-MRA results in a significant reduction of the radiation dose, fluoroscopy time and contrast medium volume used during UAE.