Refine
Document Type
- Article (26) (remove)
Has Fulltext
- yes (26)
Is part of the Bibliography
- no (26)
Keywords
- Branching fraction (4)
- LHC (3)
- ALICE (2)
- Acuris (2)
- BESIII (2)
- Charmed mesons (2)
- Electroweak interaction (2)
- Hadronic decays (2)
- Lepton colliders (2)
- Leptonic, semileptonic & radiative decays (2)
Institute
- Physik (20)
- Frankfurt Institute for Advanced Studies (FIAS) (6)
- Informatik (6)
- Medizin (3)
Relative fractions and phases of the intermediate decays are determined. With the detection efficiency estimated by the results of the amplitude analysis, the branching fraction of Dþ s → K−Kþπþπ0 decay is measured to be ð5.42 0.10stat 0.17systÞ%.
By using 6.32 fb−1 of data collected with the BESIII detector at center-of-mass energies between 4.178 and 4.226 GeV, we perform an amplitude analysis of the decay D+s ! K0S + 0 and determine the relative fractions and phase differences of different intermediate processes, which include K0S (770)+, K0S (1450)+, K (892)0 +, K (892)+ 0, and K (1410)0 +. With the detection efficiency based on the amplitude analysis results, the absolute branching fraction is measured to be B(D+s ! K0S + 0) = (5.43 ± 0.30stat ± 0.15syst) × 10−3.
Objectives: A conometric concept was recently introduced in which conical implant abutments hold the matching crown copings by friction alone, eliminating the need for cement or screws. The aim of this in vitro study was to assess the presence of microgap formation and bacterial leakage at the Acuris conometric restorative interface of three different implant abutment systems. Material and methods: A total of 75 Acuris samples of three implant-abutment systems (Ankylos, Astra Tech EV, Xive) were subjected to microbiological (n = 60) and scanning electron microscopic (SEM) investigation (n = 15). Bacterial migration into and out of the conical coupling system were analyzed in an anaerobic workstation for 48, 96, 144, and 192 h. Bacterial DNA quantification using qrt-PCR was performed at each time point. The precision of the conometric coupling and internal fit of cemented CAD/CAM crowns on corresponding Acuris TiN copings were determined by means of SEM. Results: qrt-PCR results failed to demonstrate microbial leakage from or into the Acuris system. SEM analysis revealed minute punctate microgaps at the apical aspect of the conometric junction (2.04 to 2.64 µm), while mean cement gaps of 12 to 145 µm were observed at the crown-coping interface. Conclusions: The prosthetic morse taper connection of all systems examined does not allow bacterial passage. Marginal integrity and internal luting gap between the ceramic crown and the coping remained within the clinically acceptable limits. Clinical relevance: Conometrically seated single crowns provide sufficient sealing efficiency, relocating potential misfits from the crown-abutment interface to the crown-coping interface.
The Born cross sections of the e+e− → D*+D*− and e+e− → D*+D− processes are measured using e+e− collision data collected with the BESIII experiment at center-of-mass energies from 4.085 to 4.600 GeV, corresponding to an integrated luminosity of 15.7 fb−1. The results are consistent with and more precise than the previous measurements by the Belle, Babar and CLEO collaborations. The measurements are essential for understanding the nature of vector charmonium and charmonium-like states.
Seit gut zwanzig Jahren sind keine Zweifel mehr erlaubt: Heinrich Heine ist in seine deutsche Heimat wieder definitiv heimgekehrt, und die große Heine-Ökumene scheint angebrochen. Denn wohl erstmalig in der Geschichte herrscht heute im deutschsprachigen Raum ein universeller und ungebrochener Konsens zu dem Dichter, daß er jedem, der die wechselhafte Geschichte dieses ungezogen Lieblings der Grazien in seinem Vaterlande kennt, fast verdächtig anmuten muß: Traut man doch gerade als alter Heine-Kämpe da dem Frieden, ja bisweilen den Augen nicht. Und so triumphal der Einzug - und selbst sein Heros Napoleon hat in Düsseldorf wohl keinen triumphaleren gehalten - , den der inzwischen allseits Gefeierte beispielsweise 1997 zum zweihundersten Jubiläum in seiner Geburtstadt hielt, das mit allem gebührenden Glanz und Gloria als mediale Event und internationales wissenschaftliches Happening, gar als germanistisches Love-In begangen wurde, überkam den eingefleischten Heine-Verehrer bei aller Genugtuung dabei doch fast ein leichtes Unbehagen, ein fast nostalgisches Heimweh nach jener nicht allzu fernen, doch nun versunken
anmutenden Äone, wo, wie die verklärende Erinnerung es suggeriert, um und über den Dichter noch so aufwühlend wie aufschlußreich gestritten wurde.
We report a measurement of the observed cross sections of e+ e− → J/ψX based on 3.21 fb − 1 of data accumulated at energies from 3.645 to 3.891 GeV with the BESIII detector operated at the BEPCII collider. In analysis of the cross sections, we measured the decay branching fractions of B(ψ(3686) → J/ψX) = (64.4 ± 0.6 ± 1.6)% and B(ψ(3770) → J/ψX) = (0.5 ± 0.2 ± 0.1)% for the first time. The energy-dependent line shape of these cross sections cannot be well described by two Breit-Wigner (BW) amplitudes of the expected decays ψ (3686) → J/ψX and ψ(3770) → J/ψX. Instead, it can be better described with one more BW amplitude of the decay R(3760)→ J/ψX. Under this assumption, we extracted the R (3760) mass M R (3760 ) = 3766.2 ± 3.8 ± 0.4 MeV/c2, total width Γ tot R ( 3760 ) = 22.2 ± 5.9 ± 1.4 MeV, and product of leptonic width and decay branching fraction
ΓeeR(3760) B[R(3760) → J/ψX] = (79.4 ± 85.5 ± 11.7) eV. The significance of the R(3760) is 5.3σ. The first uncertainties of these measured quantities are from fits to the cross sections and second systematic.
This paper reports on Monte Carlo simulation results for future measurements of the moduli of time-like proton electromagnetic form factors, |GE | and |GM|, using the ¯pp → μ+μ− reaction at PANDA (FAIR). The electromagnetic form factors are fundamental quantities parameterizing the electric and magnetic structure of hadrons. This work estimates the statistical and total accuracy with which the form factors can be measured at PANDA, using an analysis of simulated data within the PandaRoot software framework. The most crucial background channel is ¯pp → π+π−,due to the very similar behavior of muons and pions in the detector. The suppression factors are evaluated for this and all other relevant background channels at different values of antiproton beam momentum. The signal/background separation is based on a multivariate analysis, using the Boosted Decision Trees method. An expected background subtraction is included in this study, based on realistic angular distribuations of the background contribution. Systematic uncertainties are considered and the relative total uncertainties of the form factor measurements are presented.
Es ist nicht üblich, Brecht und Celan in einem Atemzug zu nennen. Zu sehr dominiert die Vorstellung von dem hermetischen Lyriker hier, der eher mit Hölderlin, Mallarmé und Rilke in Zusammenhang gebracht wird und sich in der raffinierten und weltabgewandten Verschlüsselung ausgedrückt haben soll, und dem operativen Dichter dort, der, um in das politische Handgemenge unmittelbar eingreifen zu können und dort seine Wirkungen zu erzielen, sich einer möglichst kommunikativen und transparenten Sprache verschrieb. Woher sollten sich dann ihre Sphären je berühren? Indes, sie berühren sich, und nicht zuletzt dadurch, dass Celan selber noch in seiner letzten und zunehmend umdüsterten Lebensphase sich wiederholt und ausdrücklich auf Brecht bezogen hat.
Encouraging clinical results were reported on a novel cone-in-cone coupling for the fixation of dental implant-supported crowns (Acuris, Dentsply Sirona Implants, Mölndal, Sweden). However, the presence or absence of a microgap and a potential bacterial leakage at the conometric joint has not yet been investigated. A misfit and a resulting gap between the conometric components could potentially serve as a bacterial reservoir that promotes plaque formation, which in turn may lead to inflammation of the peri-implant tissues. Thus, a two-fold study set-up was designed in order to evaluate the bidirectional translocation of bacteria along conometrically seated single crowns. On conometric abutments filled with a culture suspension of anaerobic bacteria, the corresponding titanium nitride-coated (TiN) caps were fixed by friction. Each system was sterilized and immersed in culture medium to provide an optimal environment for microbial growth. Positive and negative controls were prepared. Specimens were stored in an anaerobic workstation, and total and viable bacterial counts were determined. Every 48 h, samples were taken from the reaction tubes to inoculate blood agar plates and to isolate bacterial DNA for quantification using qrt-PCR. In addition, one Acuris test system was subjected to scanning electron microscopy (SEM) to evaluate the precision of fit of the conometric coupling and marginal crown opening. Throughout the observational period of one week, blood agar plates of the specimens showed no viable bacterial growth. qrt-PCR, likewise, yielded a result approaching zero with an amount of about 0.53 × 10−4 µg/mL DNA. While the luting gap/marginal opening between the TiN-cap and the ceramic crown was within the clinically acceptable range, the SEM analysis failed to identify a measurable microgap at the cone-in-cone junction. Within the limits of the in-vitro study it can be concluded that the Acuris conometric interface does not allow for bacterial translocation under non-dynamic loading conditions.