Refine
Year of publication
- 2019 (3) (remove)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- Exercise challenge at an ambient temperature (1)
- Exercise challenge in a cold chamber (1)
- Exercise-induced bronchoconstriction (1)
- Methacholine challenge test (1)
- alcoholic liver disease (1)
- alcoholic liver injury (1)
- biomarkers (1)
- drug induced liver injury (1)
- herb induced liver injury (1)
- liver injury (1)
Institute
- Medizin (2)
- Frankfurt Institute for Advanced Studies (FIAS) (1)
- Informatik (1)
- Physik (1)
Background: Physical activity is an important part of life, and hence exercise-induced bronchoconstriction (EIB) can reduce the quality of life. A standardized test is needed to diagnose EIB. The American Thoracic Society (ATS) guidelines recommend an exercise challenge in combination with dry air. We investigated the feasibility of a new, ATS guidelines conform exercise challenge in a cold chamber (ECC) to detect EIB. The aim of this study was to investigate the surrogate marker reaction to methacholine, ECC and exercise challenge in ambient temperature for the prediction of a positive reaction and to re-evaluate the reproducibility of the response to an ECC.
Methods: Seventy-eight subjects aged 6 to 40 years with suspected EIB were recruited for the study. The subjects performed one methacholine challenge, two ECCs, and one exercise challenge at an ambient temperature. To define the sensitivity and specificity of the predictor, a receiver-operating characteristic curve was plotted. The repeatability was evaluated using the method described by Bland and Altman (95% Limits of agreement).
Results: The following cut-off values showed the best combination of sensitivity and specificity: the provocation dose causing a 20% decrease in the forced expiratory volume in 1 s (PD20FEV1) of methacholine: 1.36 mg (AUC 0.69, p < 0.05), the maximal decrease in FEV1 during the ECC: 8.5% (AUC 0.78, p < 0.001) and exercise challenges at ambient temperatures: FEV1 5.2% (AUC 0.64, p = 0.13). The median decline in FEV1 was 14.5% (0.0–64.2) during the first ECC and 10.7% (0.0–52.5) during the second ECC. In the comparison of both ECCs, the Spearman rank correlation of the FEV1 decrease was r = 0.58 (p < 0.001). The 95% limits of agreement (95% LOAs) for the FEV1 decrease were − 17.7 to 26.4%.
Conclusions: The surrogate markers PD20FEV1 of methacholine and maximal decrease in FEV1 during ECC can predict a positive reaction in another ECC, whereas the maximal FEV1 decrease in an exercise challenge at an ambient temperature was not predictive. Compared with previous studies, we can achieve a similar reproducibility with an ECC.
Clinical trial registration: NCT02026492 (retrospectively registered 03/Jan/2014).
Liver injuries caused by the use of exogenous compounds such as drugs, herbs, and alcohol are commonly well diagnosed using laboratory tests, toxin analyses, or eventually reactive intermediates generated during metabolic degradation of the respective chemical in the liver and subject to covalent binding by target proteins. Conditions are somewhat different for idiosyncratic drug induced liver injury (DILI), for which metabolic intermediates as diagnostic aids are rarely available. Although the diagnosis of idiosyncratic DILI can well be established using the validated, liver specific, structured, and quantitative RUCAM (Roussel Uclaf Causality Assessment Method), there is an ongoing search for new diagnostic biomarkers that could assist in and also confirm RUCAM-based DILI diagnoses. With respect to idiosyncratic DILI and following previous regulatory letters of recommendations, selected biomarkers reached the clinical focus, including microRNA-122, microRNA-192, cytokeratin analogues, glutamate dehydrogenase, total HMGB-1 (High Mobility Group Box), and hyperacetylated HMGB-1 proteins. However, the new parameters total HMGB-1, and even more so the acetylated HMGB-1, came under critical scientific fire after misconduct at one of the collaborating partner centers, leading the EMA to recommend no longer the exploratory hyperacetylated HMGB1 isoform biomarkers in clinical studies. The overall promising nature of the recommended biomarkers was considered by EMA as highly dependent on the outstanding results of the now incriminated biomarker hyperacetylated HMGB-1. The EMA therefore correctly decided to officially retract its Letter of Support affecting all biomarkers listed above. New biomarkers are now under heavy scrutiny that will require re-evaluations prior to newly adapted recommendations. With Integrin beta 3 (ITGB3), however, a new diagnostic biomarker may emerge, possibly being drug specific but tested in only 16 patients; due to substantial remaining uncertainties, final recommendations would be premature. In conclusion, most of the currently recommended new biomarkers have lost regulatory support due to scientific misconduct, requiring now innovative approaches and re-evaluation before they can be assimilated into clinical practice.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.