Cataract surgery is one of the oldest and the most frequent outpatient clinic operations in medicine performed worldwide. The clouded human crystalline lens is replaced by an artificial intraocular lens implanted into the capsular bag. During the last six decades, cataract surgery has undergone rapid development from a traumatic, manual surgical procedure with implantation of a simple lens to a minimally invasive intervention increasingly assisted by high technology and a broad variety of implants customized for each patient’s individual requirements. This review discusses the major advances in this field and focuses on the main challenge remaining – the treatment of presbyopia. The demand for correction of presbyopia is increasing, reflecting the global growth of the ageing population. Pearls and pitfalls of currently applied methods to correct presbyopia and different approaches under investigation, both in lens implant technology and in surgical technology, are discussed.
Purpose: To report a case of autoimmune keratitis in a patient with mycobacterium tuberculosis (MBT).
Methods: An 84-year-old male with pulmonary tuberculosis (TB) was admitted with chronic, non-healing bilateral ulcerations of the inferior peripheral cornea associated with stromal and subconjunctival nodules.
Results: Clinical examination revealed circumscribed peripheral corneal ulceration with whitish nodules in adjacent stromal and subconjunctival tissue. Microbiological cultures of the corneal tissue were negative for MBT and other microbial pathogens; however, enzyme-linked immunosorbent assay (ELISA) of blood and corneal samples showed significantly elevated levels of IgM and IgA against MBT. In addition to systemic anti-tuberculosis therapy, the patient was treated topically with Polyspectran® eye drops, Dexamethasone eye drops, and Bepanthen® ointment, for 2 weeks. Both eyes showed dramatic improvement after 2 weeks.
Conclusion: The present report demonstrates that MBT is able to initiate delayed autoimmune response within the corneal tissue during an intensive phase of anti-tuberculosis treatment.
Purpose: To evaluate the efficacy of the virtual reality training simulator Eyesi to prepare surgeons for performing pars plana vitrectomies and its potential to predict the surgeons’ performance.
Methods: In a preparation phase, four participating vitreoretinal surgeons performed repeated simulator training with predefined tasks. If a surgeon was assigned to perform a vitrectomy for the management of complex retinal detachment after a surgical break of at least 60 hours it was randomly decided whether a warmup training on the simulator was required (n = 9) or not (n = 12). Performance at the simulator was measured using the built-in scoring metrics. The surgical performance was determined by two blinded observers who analyzed the video-recorded interventions. One of them repeated the analysis to check for intra-observer consistency. The surgical performance of the interventions with and without simulator training was compared. In addition, for the surgeries with simulator training, the simulator performance was compared to the performance in the operating room.
Results: Comparing each surgeon’s performance with and without warmup trainingshowed a significant effect of warmup training onto the final outcome in the operating room. For the surgeries that were preceeded by the warmup procedure, the performance at the simulator was compared with the operating room performance. We found that there is a significant relation. The governing factor of low scores in the simulator were iatrogenic retinal holes, bleedings and lens damage. Surgeons who caused minor damage in the simulation also performed well in the operating room.
Conclusions: Despite the large variation of conditions, the effect of a warmup training as well as a relation between the performance at the simulator and in the operating room was found with statistical significance. Simulator training is able to serve as a warmup to increase the average performance.
Purpose: To correlate inflammatory and proangiogenic key cytokines from undiluted vitreous of treatment-naïve central retinal vein occlusion (CRVO) patients with SD-OCT parameters.
Methods: Thirty-five patients (age 71.1 years, 24 phakic, 30 nonischemic) underwent intravitreal combination therapy, including a single-site 23-gauge core vitrectomy. Twenty-eight samples from patients with idiopathic, non-uveitis floaterectomy served as controls. Interleukin 6 (IL-6), monocyte chemoattractant protein-1 (MCP-1), and vascular endothelial growth factor (VEGF-A) levels were correlated with the visual acuity (logMar), category of CRVO (ischemic or nonischemic) and morphologic parameters, such as central macular thickness-CMT, thickness of neurosensory retina-TNeuro, extent of serous retinal detachment-SRT and disintegrity of the IS/OS and others.
Results: The mean IL-6 was 64.7pg/ml (SD ± 115.8), MCP-1 1015.7 ( ± 970.1), and VEGF-A 278.4 ( ± 512.8), which was significantly higher than the control IL-6 6.2 ± 3.4pg/ml (P=0.06), MCP-1 253.2 ± 73.5 (P<0.0000001) and VEGF-A 7.0 ± 4.9 (P<0.0006). All cytokines correlated highly with one another (correlation coefficient r=0.82 for IL-6 and MCP-1; r=0.68 for Il-6 and VEGF-A; r=0.64 for MCP-1 and VEGF-A). IL-6 correlated significantly with CMT, TRT, SRT, dIS/OS, and dELM. MCP-1 correlated significantly with SRT, dIS/OS, and dELM. VEGF-A correlated not with changes in SD-OCT, while it had a trend to be higher in the ischemic versus the nonischemic CRVO group (P=0.09).
Conclusions: The inflammatory cytokines were more often correlated with morphologic changes assessed by SD-OCT, whereas VEGF-A did not correlate with CRVO-associated changes in SD-OCT. VEGF inhibition alone may not be sufficient in decreasing the inflammatory response in CRVO therapy.
Hintergrund: Im Rahmen der Erforschung von Mechanismen der Presbyopie-Entstehung hat das Interesse an Methoden zur Linsendensitometrie wieder zugenommen. Für spezielle Fragestellungen sind flexible Untersuchungsmethoden notwendig.
Methoden: Basierend auf Aufnahmen mit der Scheimpflug-Kamera Pentacam HR (Oculus, Wetzlar) wurde ein MATLAB-Programm (V7.0, The MathWorks) erstellt, um größere Datenmengen automatisiert auszuwerten. Die Erkennung der Pupillenmitte als Referenzpunkt erfolgt mittels eines Randerkennungsalgorithmus. Als Kennzahlen dienen klassische Parameter der beschreibenden Statistik (Mittel, Minimum, Maximum, Standardabweichung und Variationskoeffizient) für einen definierten rechteckigen Bereich und für die zentrale vertikale Achse.
Ergebnisse: In einer Präliminarserie von 18 Augen war eine automatisierte Messung mit korrekter Pupillenerkennung in 80% der Fälle möglich. Verglichen mit der hersteller-eigenen Software (Pentacam 6.03r11) besitzt das eigene Programm eine erweiterte Spannweite der Messwerte. Die Messwerte können automatisch nach Excel (Microsoft) exportiert werden. Ein modularer Aufbau ermöglicht eine flexible Erweiterung für weitere Fragestellungen (z.B. Quantifizierung von Kern- und Rindentrübungen).
Schlussfolgerungen: Mittels eines selbst programmierten MATLAB-basierten Programmes kann eine automatisierte Messung und Analyse von linsndensitometrischen Parametern durchgeführt werden.
Purpose: Amblyopia with eccentric fixation, especially when not diagnosed early, is a therapeutic challenge, as visual outcome is known to be poorer than in amblyopia with central fixation. Consequently, treatment after late diagnosis is often denied. Electronic monitoring of occlusion provides us the chance to gain first focussed insight into age-dependent dose response and treatment efficiency, as well as the shift of fixation in this rare group of paediatric patients. Methods: In our prospective pilot study, we examined amblyopes with eccentric fixation during 12 months of occlusion treatment. We evaluated their visual acuity, recorded patching duration using a TheraMon®-microsensor, and determined their fixation with a direct ophthalmoscope. Dose-response relationship and treatment efficiency were calculated. Results: The study included 12 participants with strabismic and combined amblyopia aged 2.9–12.4 years (mean 6.5). Median prescription of occlusion was 7.7 h/day (range 6.6–9.9) and median daily received occlusion was 5.2 h/day (range 0.7–9.7). At study end, median acuity gain was 0.6 log units (range 0–1.6) and residual interocular visual acuity difference (IOVAD) 0.3 log units (range 0–1.8). There was neither significant acuity gain nor reduction in IOVAD after the 6th month of treatment. Children younger than 4 years showed best response with lowest residual IOVAD at study end. Efficiency calculation showed an acuity gain of approximately one line from 100 h of patching in the first 2 months and half a line after 6 months. There was a significant decline of treatment efficiency with age (p = 0.01). Foveolar fixation was achieved after median 3 months (range 1–6). Three patients (> 6 years) did not gain central fixation. Conclusion: Eccentric fixation is a challenge to therapy success. Based on electronic monitoring, our study quantified for the first time the reduction of treatment efficiency with increasing age in amblyopes with eccentric fixation. Despite some improvement in patients up to 8 years, older patients showed significantly lower treatment efficiency. In younger patients with good adherence, despite poor initial acuity, central fixation and low residual IOVAD could be attained after median 3 months. Hence, the necessity of early diagnosis and intensive occlusion should be emphasized.
Purpose: Amblyopia with eccentric fixation, especially when not diagnosed early, is a therapeutic challenge, as visual outcome is known to be poorer than in amblyopia with central fixation. Consequently, treatment after late diagnosis is often denied. Electronic monitoring of occlusion provides us the chance to gain first focussed insight into age-dependent dose response and treatment efficiency, as well as the shift of fixation in this rare group of paediatric patients. Methods: In our prospective pilot study, we examined amblyopes with eccentric fixation during 12 months of occlusion treatment. We evaluated their visual acuity, recorded patching duration using a TheraMon®-microsensor, and determined their fixation with a direct ophthalmoscope. Dose-response relationship and treatment efficiency were calculated. Results: The study included 12 participants with strabismic and combined amblyopia aged 2.9–12.4 years (mean 6.5). Median prescription of occlusion was 7.7 h/day (range 6.6–9.9) and median daily received occlusion was 5.2 h/day (range 0.7–9.7). At study end, median acuity gain was 0.6 log units (range 0–1.6) and residual interocular visual acuity difference (IOVAD) 0.3 log units (range 0–1.8). There was neither significant acuity gain nor reduction in IOVAD after the 6th month of treatment. Children younger than 4 years showed best response with lowest residual IOVAD at study end. Efficiency calculation showed an acuity gain of approximately one line from 100 h of patching in the first 2 months and half a line after 6 months. There was a significant decline of treatment efficiency with age (p = 0.01). Foveolar fixation was achieved after median 3 months (range 1–6). Three patients (> 6 years) did not gain central fixation. Conclusion: Eccentric fixation is a challenge to therapy success. Based on electronic monitoring, our study quantified for the first time the reduction of treatment efficiency with increasing age in amblyopes with eccentric fixation. Despite some improvement in patients up to 8 years, older patients showed significantly lower treatment efficiency. In younger patients with good adherence, despite poor initial acuity, central fixation and low residual IOVAD could be attained after median 3 months. Hence, the necessity of early diagnosis and intensive occlusion should be emphasized.
Purpose: Amblyopia with eccentric fixation, especially when not diagnosed early, is a therapeutic challenge, as visual outcome is known to be poorer than in amblyopia with central fixation. Consequently, treatment after late diagnosis is often denied. Electronic monitoring of occlusion provides us the chance to gain first focussed insight into age-dependent dose response and treatment efficiency, as well as the shift of fixation in this rare group of paediatric patients. Methods: In our prospective pilot study, we examined amblyopes with eccentric fixation during 12 months of occlusion treatment. We evaluated their visual acuity, recorded patching duration using a TheraMon®-microsensor, and determined their fixation with a direct ophthalmoscope. Dose-response relationship and treatment efficiency were calculated. Results: The study included 12 participants with strabismic and combined amblyopia aged 2.9–12.4 years (mean 6.5). Median prescription of occlusion was 7.7 h/day (range 6.6–9.9) and median daily received occlusion was 5.2 h/day (range 0.7–9.7). At study end, median acuity gain was 0.6 log units (range 0–1.6) and residual interocular visual acuity difference (IOVAD) 0.3 log units (range 0–1.8). There was neither significant acuity gain nor reduction in IOVAD after the 6th month of treatment. Children younger than 4 years showed best response with lowest residual IOVAD at study end. Efficiency calculation showed an acuity gain of approximately one line from 100 h of patching in the first 2 months and half a line after 6 months. There was a significant decline of treatment efficiency with age (p = 0.01). Foveolar fixation was achieved after median 3 months (range 1–6). Three patients (> 6 years) did not gain central fixation. Conclusion: Eccentric fixation is a challenge to therapy success. Based on electronic monitoring, our study quantified for the first time the reduction of treatment efficiency with increasing age in amblyopes with eccentric fixation. Despite some improvement in patients up to 8 years, older patients showed significantly lower treatment efficiency. In younger patients with good adherence, despite poor initial acuity, central fixation and low residual IOVAD could be attained after median 3 months. Hence, the necessity of early diagnosis and intensive occlusion should be emphasized.
Background: With increasing numbers of lamellar keratoplasties, eye banks are challenged to deliver precut lamellar donor tissue. In Europe, the most common technique of corneal storage is organ culture which requires a deswelling process before surgical processing. The aim of this study was to investigate the influence of different deswelling times on the cutting plane quality after microkeratome-assisted lamellar dissection.
Methods: Eight paired donor corneas (16 specimens) not suitable for transplantation were organ cultured under standard conditions at the Eye Bank of the Ludwig-Maximilians Universität, Munich, Germany. Pairs of corneal buttons were analyzed during the deswelling process in dextrane-containing medium. While one cornea was cut at an early time point during the deswelling process and put back into deswelling medium thereafter, the partner cornea was completely deswollen and dissected after 72 hours. Specimens were then further processed for scanning electron microscopy. Surface quality was assessed both digitally using Scanning Probe Imaging Processing software, and manually by three blinded graders.
Results: The corneal buttons processed at the beginning of the deswelling process had a smoother surface when compared to the partner cornea that was cut at the end of the deswelling process. In our setting, no relevant difference was detectable between manual and automated microkeratome dissection.
Conclusion: For lamellar keratoplasty, organ-cultured corneas should be processed at an early stage during the deswelling process. We interpret the smoother dissection plane during early deswelling as a result of mechanical properties in a highly hydrated cornea.
Purpose: To evaluate if repeat Descemet membrane endothelial keratoplasty (DMEK) is appropriate to achieve functional improvements in patients with corneal decompensation from secondary graft failure after primary DMEK.
Methods: This is a retrospective monocentric cohort study including 13 eyes of 13 patients with repeat DMEK for corneal decompensation following primary DMEK. Eyes with primary DMEK only and comparable preoperative corrected distance visual acuity (CDVA) served as control. Main outcome parameter was CDVA. Secondary outcome measures were central corneal thickness (CCT), endothelial cell density, and rebubbling rate (RR).
Results: The average time interval (±SD) between primary and secondary DMEK was 12.5±6 months. Preoperative CDVA (logMAR) was 1.97±0.90 in the repeat DMEK group and 1.38±0.92 in the primary DMEK group. At 6 months, both groups showed significant improvement in visual acuity (repeat DMEK group, 0.49±0.35, P<0.01 and primary DMEK group, 0.40±0.36, P<0.01). CDVA did not differ significantly between both groups at all time points examined (1, 3, and 6 months postoperatively). Mean CCT values at 3 and 6 months postoperatively did not differ significantly between the two groups (P>0.05). The RR was
23% (n=3) in both groups.
Conclusion: Repeat DMEK is a useful therapeutic approach in the setting of corneal decompensation following primary DMEK. Functional results of repeat DMEK, visual acuity in particular, are comparable to patients with single DMEK only.
Purpose: To investigate short-term (3 months follow-up) changes in visual quality following Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy (FED). Methods: In this prospective institutional case series, 51 patients that underwent DMEK for FED were included. Assessment included the Quality of Vision (QoV) questionnaire preoperatively, at 1 month, and 3 months after surgery. Secondary outcome measures were anterior segment parameters acquired by Scheimpflug imaging, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). Results: Glare, hazy vision, blurred vision, and daily fluctuation in vision were the symptoms mostly reported preoperatively. All symptoms demonstrated a significant reduction of item scores for severity, frequency, and bothersome in the course after DMEK (P < 0.01). Glare and fluctuation in vision remained to some extent during the follow-up period (median score = 1). Preoperatively, corneal densitometry correlated moderately to weakly with severity of hazy vision (rs = 0.39; P = 0.03) and frequency (rs = 0.26; P = 0.02) as well as severity (rs = 0.27; P = 0.03) of blurry vision. CDVA and central corneal thickness (CCT) did not correlate with visual complains. Conclusions: Following DMEK for FED, patient-reported visual symptoms assessed by the QoV questionnaire represent a useful tool providing valuable information on the impact of DMEK on visual quality that cannot be directly estimated by morphological parameters and visual acuity only.
Purpose: To investigate short-term (3 months follow-up) changes in visual quality following Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy (FED). Methods: In this prospective institutional case series, 51 patients that underwent DMEK for FED were included. Assessment included the Quality of Vision (QoV) questionnaire preoperatively, at 1 month, and 3 months after surgery. Secondary outcome measures were anterior segment parameters acquired by Scheimpflug imaging, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). Results: Glare, hazy vision, blurred vision, and daily fluctuation in vision were the symptoms mostly reported preoperatively. All symptoms demonstrated a significant reduction of item scores for severity, frequency, and bothersome in the course after DMEK (P < 0.01). Glare and fluctuation in vision remained to some extent during the follow-up period (median score = 1). Preoperatively, corneal densitometry correlated moderately to weakly with severity of hazy vision (rs = 0.39; P = 0.03) and frequency (rs = 0.26; P = 0.02) as well as severity (rs = 0.27; P = 0.03) of blurry vision. CDVA and central corneal thickness (CCT) did not correlate with visual complains. Conclusions: Following DMEK for FED, patient-reported visual symptoms assessed by the QoV questionnaire represent a useful tool providing valuable information on the impact of DMEK on visual quality that cannot be directly estimated by morphological parameters and visual acuity only.
Purpose: To compare the effective lens position (ELP), anterior chamber depth (ACD) changes, and visual outcomes in patients with and without pseudoexfoliation syndrome (PEX) after cataract surgery.
Design: Prospective, randomized, fellow-eye controlled clinical case series.
Methods: This prospective comparative case series enrolled 56 eyes of 56 consecutive patients with (n = 28) or without PEX (n = 28) and clinically significant cataract who underwent standard phacoemulsification and were implanted with single-piece acrylic posterior chamber intraocular lenses (IOLs). The primary outcome parameters were the ACD referring to the distance between the corneal anterior surface and the lens anterior surface, which is an indicator of the postoperative axial position of the IOL (the so-called ELP) and distance corrected visual acuity (DCVA).
Results: Before surgery, the ACD was 2.54 ± 0.42 mm in the PEX group and 2.53 ± 0.38 mm in the control group (p = 0.941). Postoperatively, the ACD was 4.29 ± 0.71 mm in the PEX group and 4.33 ± 0.72 mm in the normal group, respectively (p = 0.533). There was no significant difference in ACD changes between groups (PEX group: 1.75 ± 0.74 mm, control group: 1.81 ± 0.61 mm, p = 0.806) and DCVA pre- (p = 0.469) and postoperatively (PEX group: 0.11 ± 0.13 logMAR, control group: 0.09 ± 0.17 logMAR, p = 0.245) between groups.
Conclusion: Preoperative and postoperative ACD, as an indicator of ELP, between PEX eyes and healthy eyes after cataract surgery showed no significant difference. Phacoemulsification induced similar changes in eyes with PEX compared to healthy eyes.
Purpose: To evaluate the potential impact of rebubbling on the anterior segment parameters and refractive outcomes in patients with graft detachment following uneventful DMEK for Fuchs endothelial dystrophy (FED).
Methods: Retrospective institutional cohort study of comparing 34 eyes of 31 patients with rebubbling for graft detachment following Descemet membrane endothelial keratoplasty (DMEK) to 33 eyes of 28 patients with uneventful DMEK. Main outcome parameters were various corneal parameters obtained by Scheimpflug imaging, refractive outcome, corrected distance visual acuity (CDVA), and endothelial cell density (ECD).
Results: Anterior and posterior corneal astigmatism, corneal densitometry, central corneal thickness, and anterior chamber depth and volume showed no significant differences. Preoperative distribution of astigmatism axis orientations showed a high proportion of anterior corneal with-the-rule astigmatism (71%) in eyes requiring rebubbling. Mean postoperative cylinder in the rebubbling group (1.21 ± 0.85 D) was significantly higher compared to the controls (p = 0.04), while differences in spherical equivalent (SE) were insignificant (p = 0.24). Postoperative CDVA was 0.11 ± 0.11 in the control group compared to 0.21 ± 0.17 in the rebubbling group (p = 0.03). Eyes with subsequent rebubbling demonstrated a significantly higher endothelial cell loss (56% versus 37%) (p < 0.001).
Conclusion: Apart from higher cylinder values, refractive outcome and corneal parameters assessed by Scheimpflug imaging were comparable in eyes with rebubbling and controls. However, a reduced visual acuity and an increased endothelial cell loss should be taken into consideration prior to rebubbling especially in eyes with circumscribed graft detachment.
Purpose: The use of a non-diffractive extended-depth-of-focus (EDOF) intraocular lens (IOL) with slight myopia of −0.5 D on the non-dominant eye increases the spectacle independence and has good subjective tolerance with optical phenomena comparable to those of a monofocal IOL. This case report describes the course of a myopic patient who underwent refractive lens exchange, didn't tolerate mini-monovision and received IOL exchange therefore.
Observations: A healthy, 62-year-old male with myopia of approximately −5 D underwent refractive lens exchange with a non-diffractive EDOF-IOL on both eyes with slight myopia on the non-dominant left eye (mini-monovision). The operation was performed without any complications, postoperative treatment was due to the clinic's standard procedure. Two weeks postoperative the patient presented with uncorrected distance visual acuity of 0.0 logMAR, a subjective refraction of −0.25/−0.25/142° and corrected distance visual acuity of 0.1 logMAR on the right eye. On the left eye, distance visual acuity was 0.4 logMAR with a subjective refraction of −0.5/−0.75/9° (intended mini-monovision) and corrected distance visual acuity of 0.0 logMAR. Binocular distance visual acuity was 0.0 logMAR. The patient complained about the occurrence of optical phenomena at dim light while driving a car and subjective reduced visual acuity. After an IOL exchange on the left eye with the implantation of the same type of non-diffractive EDOF-IOL aimed for emmetropia, the patient was symptom-free and reported no more subjective complaints.
Conclusions: Despite the satisfying subjective and objective visual outcome which is proven in multiple studies, the subjective perception of a mini-monovision with a non-diffractive EDOF-IOL can vary individually. A preoperative assessment of the patient's needs and tolerance of a mini-monovision is crucial for a satisfying postoperative outcome.
Die exakte Positionierung von Intraokularlinsen in den Kapselsack ist von entscheidender Bedeutung für das postoperative visuelle Ergebnis nach Kataraktoperation oder refraktivem Linsenaustausch. Schon leichte Dezentrierungen können optische Aberrationen hervorrufen welche das Sehen der Patienten negativ beeinflussen. Besonders kommt dieses Phänomen bei sog. Premium Intraokularlinsen mit speziellen Optiken (asphärisch, torisch oder multifokal, sowie Kombinationen dieser) zum Tragen. Diese Optiken können Ihre gewünschte Wirkung nur bei exakter Positionierung entfalten. Eine postoperative Feinpositionierung ist nicht möglich, was die Ansprüche an den Operateur bei Implantation der Linsen erhöht. Minimalinvasive microinzisionelle Operationstechniken bieten heute gute Möglichkeiten, die Implantate exakt zu positionieren. Neben den Dezentrierungen können Intraokularlinsen auch dislozieren, beispielweise durch intra- oder postoperative Kapselrupturen, Linsenverziehungen oder auch Rotation der Implantate. Hier ist ein weiterer chirurgischer Eingriff von Nöten. Der Vortrag stellt dementsprechend verschiedene Videos und praktische Hinweise zur Handhabung postoperativer Linsendislokationen vor.
Introduction: For management of complicated retinal detachments, a pars plana vitrectomy with temporary silicone oil (SO) fill is the method of choice. According to literature, the retinal redetachment rate varies between <10% and >70% with around 36% in our own group (retrospective data analysis, n = 119 eyes).
Methods: The main goal was to reduce the retinal redetachment rate. Standard operating procedures (SOPs) and evaluation protocols (EVALPs) were developed to prospectively analyse risk factors. Lab analysis of SO was performed, and the role of surgical experience was evaluated and investigated with Eyesi®.
Results: We achieved a significant reduction of the retinal redetachment rate (to 6.80%, n = 101, p = 0.002). After surgery with SO injection, neither further membrane peeling (in 16.5%) nor retinal laser coagulation (in 100%) during revision surgery had a significant effect on the reattachment rate (p = 0.167, p = 0.23), while extensive additional laser coagulation reduced visual acuity (p = 0.01). A 3-port approach had to be set up to complete SO removal. A difference in success rate depending on surgical experience was confirmed, and the performance in Eyesi correlated with that in the patients' eye.
Conclusions: A SOP- and EVALP-based management and new strategies to secure the surgical performance seem to be essential for successful surgery.