Refine
Year of publication
Document Type
- Article (16)
- Conference Proceeding (3)
Language
- English (19)
Has Fulltext
- yes (19)
Is part of the Bibliography
- no (19)
Keywords
- Accelerators & Beams (2)
- Atomic, Molecular & Optical (2)
- storage rings (2)
- Accelerators & storage rings (1)
- Atomic & molecular beams (1)
- Atoms (1)
- Beam loss (1)
- Charge-transfer collisions (1)
- Circular accelerators (1)
- CsI(Tl) scintillators (1)
Institute
- Physik (17)
- ELEMENTS (14)
- Frankfurt Institute for Advanced Studies (FIAS) (1)
In the next years the Facility for Antiproton and Ion Research FAIR will be constructed at the GSI Helmholtzzentrum fur Schwerionenforschung in Darmstadt, Germany. This new accelerator complex will allow for unprecedented and pathbreaking research in hadronic, nuclear, and atomic physics as well as in applied sciences. This manuscript will discuss some of these research opportunities, with a focus on few-body physics.
The HITRAP linear decelerator currently being set up at GSI will provide slow, few keV/u highly charged ions for atomic physics experiments. The expected beam intensity is up to 105 ions per shot. To optimize phase and amplitude of the RF systems intensity, bunch length and kinetic energy of the particles need to be monitored. The bunch length that we need to fit is about 2 ns, which is typically measured by capacitive pickups. However, they do not work for the low beam intensities that we face. We investigated the bunch length with a fast CVD diamond detector working in single particle counting mode. Averaging over 8 shots yields a clear, regular picture of the bunched beam. Energy measurements by capacitive pickups are limited by the presence of intense primary and partially decelerated beam and hence make tuning of the IH-structure impossible. The energy of the decelerated fraction of the beam behind the first deceleration cavity was determined to about 10 % accuracy with a permanent dipole magnet combined with a MCP. Better detector calibration should help reaching the required 1%. Design of the detectors as well as the results of the measurements will be presented.
8th International Conference on Nuclear Physics at Storage Rings Stori11, October 9-14, 2011 Laboratori Nazionale di Frascati, Italy.
Storage rings offer the possibility of measuring proton- and alpha-induced reactions in inverse kinematics. The combination of this approachwith a radioactive beamfacility allows, in principle, the determination of the respective cross sections for radioactive isotopes. Such data are highly desired for a better understanding of astrophysical nucleosynthesis processes like the p-process. A pioneering experiment has been performed at the Experimental Storage Ring (ESR) at GSI using a stable 96Ru beam at 9-11 AMeV and a hydrogen target. Monte-Carlo simulations of the experiment were made using the Geant4 code. In these simulations, the experimental setup is described in detail and all reaction channels can be investigated. Based on the Geant4 simulations, a prediction of the shape of different spectral components can be performed. A comparison of simulated predictions with the experimental results shows a good agreement and allows the extraction of the cross section.
The process of electron-loss to the continuum (ELC) has been studied for the collision systems U28++H2 at a collision energy of 50 MeV/u, U28++N2 at 30 MeV/u, and U28++Xe at 50 MeV/u. The energy distributions of cusp electrons emitted at an angle of 0∘ with respect to the projectile beam were measured using a magnetic forward-angle electron spectrometer. For these collision systems far from equilibrium charge state, a significantly asymmetric cusp shape is observed. The experimental results are compared to calculations based on first-order perturbation theory, which predict an almost symmetric cusp shape. Some possible reasons for this discrepancy are discussed.
A heavy-ion detector was developed for decay studies in the Experimental Storage Ring (ESR) at the GSI Helmholtz Centre for Heavy Ion Research in Darmstadt, Germany. This detector serves as a prototype for the in-pocket particle detectors for future experiments with the Collector Ring (CR) at FAIR (Facility for Antiproton and Ion Research). The detector includes a stack of six silicon pad sensors, a double-sided silicon strip detector (DSSD), and a CsI(Tl) scintillation detector. It was used successfully in a recent experiment for the detection of the β+-decay of highly charged 142Pm60+ ions. Based on the technique for particle identification and an energy resolution of 0.9% for and 0.5% for E (Full Width at Half Maximum (FWHM)), the detector is well-suited to distinguish neighbouring isobars in the region of interest.
One of the aims of the SPARC collaboration [1] at FAIR is to perform precision atomic physics expe- riments with highly charged heavy ions at the High Energy Storage Ring (HESR). An internal target is indis- pensably an integral part for many such experiments. Ions with different charge states, which are obtained as a result of interaction of an ion beam with the target, need to be effectively separated and detected. In this work we present ion optical studies unambiguously showing the feasibility of SPARC experiments at the HESR.
The 124Xe(p,γ) reaction has been measured for the first time at energies around the Gamow window by using stored ions at the ESR facility. The desired beam energies below 10 MeV/u introduce new experimental challenges like windowless ions detection under UHV conditions, extremely short beam lifetimes and efficient beam deceleration and cooling, all of which have been successfully met.
Accurate spectroscopy of highly-charged high-Z ions in a storage ring is demonstrated to be feasible by the use of specially adapted crystal optics. The method has been applied for the measurement of the 1s Lamb shift in hydrogen-like gold (Au+78) in a storage ring through spectroscopy of the Lyman x-rays. This measurement represents the first result obtained for a high-Z element using high-resolution wavelength-dispersive spectroscopy in the hard x-ray regime, paving the way for sensitivity to higher- order QED effects.