Refine
Has Fulltext
- yes (25)
Is part of the Bibliography
- no (25)
Keywords
- COVID-19 (5)
- SARS-CoV-2 (3)
- AIDS (1)
- Accelerators & Beams (1)
- Accelerators & storage rings (1)
- Antibody avidity (1)
- Antiretroviral therapy (1)
- Atomic & molecular beams (1)
- Atomic, Molecular & Optical (1)
- B.1.617.1 (1)
Institute
- Medizin (22)
- ELEMENTS (2)
- Physik (2)
- Biochemie, Chemie und Pharmazie (1)
Highlights
• Open pulmonary tuberculosis patient discharge policy was not reviewed for decades.
• After smear-negativity conversion, substantial cultural positivity may remain.
• It remains unclear, whether smear-negative patients still may be infective.
• The clinical relevance of this finding warrants further investigation.
Abstract
Objectives: Patients with open pulmonary tuberculosis (opTB) are subject to strict isolation rules. Sputum smear microscopy is used to determine infectivity, but sensitivity is lower than for culture. This study aimed to investigate the clinical relevance of this mismatch in contemporary settings.
Methods: Differential results between microscopy and culture were determined at the time of microscopic sputum conversion, from all patients with opTB between 01/2013 and 12/2017. In addition, data on HIV, multi/extensive drug-resistant TB status, time to smear- and cultural-negativity conversion were analyzed; and a Kaplan-Meier curve was developed.
Results: Of 118 patients with opTB, 58 had demographic data available for microbiological and clinical follow-up analysis; among these, 26 (44.8%) had still at least one positive culture result. Median time from opTB-treatment initiation to full microscopic sputum- or culture conversion, was 16.5 days (range 2-105), and 20 days (1-105), respectively (median difference: +3.5 days). Sixteen days after de-isolation, >90% had converted culturally. HIV- or multi/extensive drug-resistant TB status did not impact conversion time.
Conclusion: When patients with opTB were de-isolated after 3 negative sputum smear microscopy tests, a substantial part still revealed cultural growth of Mycobacterium tuberculosis complex, but it remains unclear, whether smear-negative and culturally-positive individuals on therapy are really infective. Thus, the clinical relevance of this finding warrants further investigation.
Background: In recent months, Omicron variants of SARS-CoV-2 have become dominant in many regions of the world, and case numbers with Omicron subvariants BA.1 and BA.2 continue to increase. Due to numerous mutations in the spike protein, the efficacy of currently available vaccines, which are based on Wuhan-Hu 1 isolate of SARS-CoV-2, is reduced, leading to breakthrough infections. Efficacy of monoclonal antibody therapy is also likely impaired.
Methods: In our in vitro study using A549-AT cells constitutively expressing ACE2 and TMPRSS2, we determined and compared the neutralizing capacity of vaccine-elicited sera, convalescent sera and monoclonal antibodies against authentic SARS-CoV-2 Omicron BA.1 and BA.2 compared with Delta.
Findings: Almost no neutralisation of Omicron BA.1 and BA.2 was observed using sera from individuals vaccinated with two doses 6 months earlier, regardless of the type of vaccine taken. Shortly after the booster dose, most sera from triple BNT162b2-vaccinated individuals were able to neutralise both Omicron variants. In line with waning antibody levels three months after the booster, only weak residual neutralisation was observed for BA.1 (26%, n = 34, 0 median NT50) and BA.2 (44%, n = 34, 0 median NT50). In addition, BA.1 but not BA.2 was resistant to the neutralising monoclonal antibodies casirivimab/imdevimab, while BA.2 exhibited almost a complete evasion from the neutralisation induced by sotrovimab.
Interpretation: Both SARS-CoV-2 Omicron subvariants BA.1 and BA.2 escape antibody-mediated neutralisation elicited by vaccination, previous infection with SARS-CoV-2, and monoclonal antibodies. Waning immunity renders the majority of tested sera obtained three months after booster vaccination negative in BA.1 and BA.2 neutralisation. Omicron subvariant specific resistance to the monoclonal antibodies casirivimab/imdevimab and sotrovimab emphasizes the importance of genotype-surveillance and guided application.
Funding: This study was supported in part by the Goethe-Corona-Fund of the Goethe University Frankfurt (M.W.) and the Federal Ministry of Education and Research (COVIDready; grant 02WRS1621C (M.W.).
Introduction Disseminated infection due to non-tuberculous mycobacteria has been a major factor of mortality and comorbidity in HIV patients. Until 2018, U.S. American guidelines have recommended antimycobacterial prophylaxis in patients with low CD4 cell counts, a practice that has not been adopted in Europe. This study aimed at examining the impact of disseminated NTM disease on clinical outcome in German HIV patients with a severe immunodeficiency. Materials and methods In this retrospective case control study, HIV patients with disseminated NTM disease were identified by retrospective chart review and matched by their CD4 cell counts to HIV patients without NTM infection in a 1:1 alocation. Primary endpoints were mortality and time to first rehospitalisation. In addition, other opportunistic diseases, as well as antimycobacterial and antiretroviral treatments were examined. Results Between 2006 and 2016, we identified 37 HIV patients with disseminated NTM disease. Most of them were suffering from infections due to M. avium complex (n = 31, 77.5%). Time to event analysis showed a non-significant trend to higher mortality in patients with disseminated NTM disease (p = 0.24). Rehospitalisation took place significantly earlier in patients with disseminated NTM infections (median 40.5 days vs. 109 days, p<0.0001). Conclusion In this retrospective case control study, we could demonstrate that mortality is not significantly higher in HIV patients with disseminated NTM disease in the ART era, but that they require specialised medical attention in the first months following discharge.
Background: Due to the coronavirus disease 2019 (COVID-19) pandemic, interventions in the upper airways are considered high-risk procedures for otolaryngologists and their colleagues. The purpose of this study was to evaluate limitations in hearing and communication when using a powered air-purifying respirator (PAPR) system to protect against severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) transmission and to assess the benefit of a headset. Methods: Acoustic properties of the PAPR system were measured using a head and torso simulator. Audiological tests (tone audiometry, Freiburg speech test, Oldenburg sentence test (OLSA)) were performed in normal-hearing subjects (n = 10) to assess hearing with PAPR. The audiological test setup also included simulation of conditions in which the target speaker used either a PAPR, a filtering face piece (FFP) 3 respirator, or a surgical face mask. Results: Audiological measurements revealed that sound insulation by the PAPR headtop and noise, generated by the blower-assisted respiratory protection system, resulted in significantly deteriorated hearing thresholds (4.0 ± 7.2 dB hearing level (HL) vs. 49.2 ± 11.0
Background: Antibody detection of SARS-CoV-2 requires an understanding of its variation, course, and duration.
Methods: Antibody response to SARS-CoV-2 was evaluated over 5–430 days on 828 samples across COVID-19 severity levels, for total antibody (TAb), IgG, IgA, IgM, neutralizing antibody (NAb), antibody avidity, and for receptor-binding-domain (RBD), spike (S), or nucleoprotein (N). Specificity was determined on 676 pre-pandemic samples.
Results: Sensitivity at 30–60 days post symptom onset (pso) for TAb-S/RBD, TAb-N, IgG-S, IgG-N, IgA-S, IgM-RBD, and NAb was 96.6%, 99.5%, 89.7%, 94.3%, 80.9%, 76.9% and 92.8%, respectively. Follow-up 430 days pso revealed: TAb-S/RBD increased slightly (100.0%); TAb-N decreased slightly (97.1%); IgG-S and IgA-S decreased moderately (81.4%, 65.7%); NAb remained positive (94.3%), slightly decreasing in activity after 300 days; there was correlation with IgG-S (Rs = 0.88) and IgA-S (Rs = 0.71); IgG-N decreased significantly from day 120 (15.7%); IgM-RBD dropped after 30–60 days (22.9%). High antibody avidity developed against S/RBD steadily with time in 94.3% of patients after 430 days. This correlated with persistent antibody detection depending on antibody-binding efficiency of the test design. Severe COVID-19 correlated with earlier and higher antibody response, mild COVID-19 was heterogeneous with a wide range of antibody reactivities. Specificity of the tests was ≥99%, except for IgA (96%).
Conclusion: Sensitivity of anti-SARS-CoV-2 assays was determined by test design, target antigen, antibody avidity, and COVID-19 severity. Sustained antibody detection was mainly determined by avidity progression for RBD and S. Testing by TAb and for S/RBD provided the highest sensitivity and longest detection duration of 14 months so far.
Background: In the past, protease inhibitors (PIs) and the reverse transcriptase inhibitor abacavir were identified increasing the risk for thromboembolic complications and cardiovascular events (CVE) of HIV infected patients taking a combination antiretroviral therapy (cART). Results of the previous HIV-PLA I-study lead to the assumption that platelet activation could play a substantial role in increasing CVE risks.
Methods: The open label, monocentric HIV-PLA II-study investigated HIV-1-infected, therapy-naïve adults (n=45) starting with cART, consisting either of boosted PI (atazanavir, n= 6, darunavir, n=11), NNRTI (efavirenz, n=14) or integrase inhibitor (raltegravir, n=14), each plus tenofovir/emtricitabine co-medication. Main exclusion criteria were tobacco smoking, the intake of NSAIDs or abacavir or past CVE. Platelet adhesive molecule p-selectin (CD62P) and FITC anti-human Integrin α-IIb/Integrin β-3 (CD41/CD61) antibody (PAC-1) binding, monocyte CD11b/monocyte-associated CD41 expression and the endogenous thrombin potential (ETP) were assessed ex vivo-in vitro at baseline, weeks 4, 12 and 24. Therapy regimens were blinded to the investigators for laboratory and statistical analyses.
Results: CD11b and ETP showed no significant changes or differences between all study groups. In contrast, the mean + SD mean fluorescence units (MFI) of CD62P and PAC-1 increased significantly in patients taking PI, indicating an enhanced potential for thrombocyte activation and aggregation.
Conclusion: CD62P expression, detecting the ɑ-platelet degranulation of pro-inflammatory and pro-thrombotic factors and adhesive proteins, and PAC-1 expression, representing a marker for conformation changes of the GIIb/IIIa receptor, increased significantly in patients taking HIV protease inhibitors. The findings of this study revealed a yet unknown pathway of platelet activation, possibly contributing to the increased risk for CVE under HIV protease inhibitor containing cART.
Clinical Trial Registration No.: DRKS00000288.
Hintergrund: Ab Frühjahr 2020 kam es zur weltweiten Verbreitung von SARS-CoV‑2 mit der heute als erste Welle der Pandemie bezeichneten Phase ab März 2020. Diese resultierte an vielen Kliniken in Umstrukturierungen und Ressourcenverschiebungen. Ziel unserer Arbeit war die Erfassung der Auswirkungen der Pandemie auf die universitäre Hals-Nasen-Ohren(HNO)-Heilkunde für die Forschung, Lehre und Weiterbildung. Material und Methoden: Die Direktorinnen und Direktoren der 39 Universitäts-HNO-Kliniken in Deutschland wurden mithilfe einer strukturierten Online-Befragung zu den Auswirkungen der Pandemie im Zeitraum von März bis April 2020 auf die Forschung, Lehre und die Weiterbildung befragt. Ergebnisse: Alle 39 Direktorinnen und Direktoren beteiligten sich an der Umfrage. Hiervon gaben 74,4 % (29/39) an, dass es zu einer Verschlechterung ihrer Forschungstätigkeit infolge der Pandemie gekommen sei. Von 61,5 % (24/39) wurde berichtet, dass pandemiebezogene Forschungsaspekte aufgegriffen wurden. Von allen Kliniken wurde eine Einschränkung der Präsenzlehre berichtet und 97,5 % (38/39) führten neue digitale Lehrformate ein. Im Beobachtungszeitraum sahen 74,4 % der Klinikdirektoren die Weiterbildung der Assistenten nicht gefährdet. Schlussfolgerung: Die Ergebnisse geben einen Einblick in die heterogenen Auswirkungen der Pandemie. Die kurzfristige Bearbeitung pandemiebezogener Forschungsthemen und die Einführung innovativer digitaler Konzepte für die studentische Lehre belegt eindrücklich das große innovative Potenzial und die schnelle Reaktionsfähigkeit der HNO-Universitätskliniken, um auch während der Pandemie ihre Aufgaben in der Forschung, Lehre und Weiterbildung bestmöglich zu erfüllen.
The capacity of convalescent and vaccine-elicited sera and monoclonal antibodies (mAb) to neutralize SARS-CoV-2 variants is currently of high relevance to assess the protection against infections.
We performed a cell culture-based neutralization assay focusing on authentic SARS-CoV-2 variants B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.427/B.1.429 (Epsilon), all harboring the spike substitution L452R.
We found that authentic SARS-CoV-2 variants harboring L452R had reduced susceptibility to convalescent and vaccine-elicited sera and mAbs. Compared to B.1, Kappa and Delta showed a reduced neutralization by convalescent sera by a factor of 5.71 and 3.64, respectively, which constitutes a 2-fold greater reduction when compared to Epsilon. BNT2b2 and mRNA1273 vaccine-elicited sera were less effective against Kappa, Delta, and Epsilon compared to B.1. No difference was observed between Kappa and Delta towards vaccine-elicited sera, whereas convalescent sera were 1.6-fold less effective against Delta, respectively. Both B.1.617 variants Kappa (+E484Q) and Delta (+T478K) were less susceptible to either casirivimab or imdevimab.
In conclusion, in contrast to the parallel circulating Kappa variant, the neutralization efficiency of convalescent and vaccine-elicited sera against Delta was moderately reduced. Delta was resistant to imdevimab, which however, might be circumvented by a combination therapy with casirivimab together.
The capacity of convalescent and vaccine-elicited sera and monoclonal antibodies (mAb) to neutralize SARS-CoV-2 variants is currently of high relevance to assess the protection against infections. We performed a cell culture-based neutralization assay focusing on authentic SARS-CoV-2 variants B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.427/B.1.429 (Epsilon), all harboring the spike substitution L452R. We found that authentic SARS-CoV-2 variants harboring L452R had reduced susceptibility to convalescent and vaccine-elicited sera and mAbs. Compared to B.1, Kappa and Delta showed a reduced neutralization by convalescent sera by a factor of 8.00 and 5.33, respectively, which constitutes a 2-fold greater reduction when compared to Epsilon. BNT2b2 and mRNA1273 vaccine-elicited sera were less effective against Kappa, Delta, and Epsilon compared to B.1. No difference was observed between Kappa and Delta towards vaccine-elicited sera, whereas convalescent sera were 1.51-fold less effective against Delta, respectively. Both B.1.617 variants Kappa (+E484Q) and Delta (+T478K) were less susceptible to either casirivimab or imdevimab. In conclusion, in contrast to the parallel circulating Kappa variant, the neutralization efficiency of convalescent and vaccine-elicited sera against Delta was moderately reduced. Delta was resistant to imdevimab, which, however, might be circumvented by combination therapy with casirivimab together.
Objectives: To prospectively evaluate lung ultrasound in comparison with radiography and computed tomography (CT) for detecting HIV-related lung diseases.
Methods: Ultrasound examinations in HIV-positive patients were evaluated by three raters; available conventional imaging was evaluated by another rater. Results were compared with each other and the definite diagnosis. Interrater reliability was calculated for each finding.
Results: Eighty HIV-positive patients received lung ultrasound examinations; 74 received conventional imaging. The overall sensitivity was 97.5% for CT, 90.7% for ultrasound and 78.1% for radiography. The most common diagnoses were Pneumocystis jirovecii pneumonia (21 cases) and bacterial pneumonia (17 cases). The most frequent and sensitive ultrasonographic findings were interstitial abnormalities indicated by B-lines, independent of the aetiology. Interrater reliability was high for interstitial abnormalities (ICC=0.82). The interrater reliability for consolidations and effusion increased during the study (r=0.88 and r=0.37, respectively).
Conclusions: Ultrasound is a fast, reliable and sensitive point-of-care tool, particularly in detecting interstitial lung disease, which is common in HIV-associated illness. It does not effectively discriminate between different aetiologies. A longer learning period might be required to reliably identify consolidations and effusions.