As the successor of the EUROTRANS project, the MAX project is aiming to continue the R&D effects for a European Accelerator-Driven System and to bring the conceptual design to reality. The layout of the driver linac for MAX will follow the reference design made for the XT-ADS phase of the EUROTRANS project. For the injector part, new design strategies and approaches, e.g. half resonant frequency, half transition-energy between the RFQ and the CH-DTL, and using the 4-rod RFQ structure instead of the originally proposed 4-vane RFQ, have been conceived and studied to reach a more reliable CW operation at reduced costs. In this paper, the design and simulation results of the MAX injector are presented.
EUROTRANS is a European research program for the transmutation of high level nuclear waste in an accelerator-driven system (ADS). As proposed, the driver linac needs to deliver a 2.5–4 mA, 600 MeV continuous-wave (CW) proton beam and later a 20 mA, 800 MeV one to the spallation target in the prototype-scale and industrial-scale demonstration phases, respectively. This paper is focusing on the conceptual studies performed with respect to the 17 MeV injector. First, the special beam dynamics strategies and methods, which have been developed and applied to design a current-variable injector up to 30 mA for allowing an easy upgrade without additional R&D costs, will be introduced. Then the error study made for evaluating the tolerance limits of the designed injector will be presented as well.
This work is focused on the anomalous skin effect in copper and how it affects the efficiency of copper-cavities in the temperature range 40-50 K. The quality factor Q of three coaxial cavities was measured over the temperature range from 10 K to room temperature in the experiment. The three coaxial cavities have the same structure, but different lengths, which correspond to resonant frequencies: around 100 MHz, 220 MHz and 340 MHz. Furthermore, the effects of copper-plating and additional baking in the vacuum oven on the quality factor Q are studied in the experiment. The motivation is to check the feasibility of an efficient, pulsed, ion linac, operated at cryogenic temperatures.
A test stand for optical beam tomography was developed. As a new non-destructive beam-diagnostic system for high current ion beams, the test stand will be installed in the low energy beam transport section (LEBT) of the Frankfurt Neutron Source (FRANZ) behind the chopper system. The test stand consists of a rotatable vacuum chamber with a mounted CCD camera. The maximum rotation angle amounts to 270°. In a first phase the optical beam profile measurement and 3D density reconstruction is tested with a time independent 10 keV He beam. The measurements and performance of data processing algorithms are compared with the beam transport simulations. In a later phase the performance with time dependent beams (120 keV, 200 mA) at a repetition rate of 250 kHz and a duty cycle of 2.5% has to be evaluated. An overview of the first phase results is shown.
The HITRAP linear decelerator currently being set up at GSI will provide slow, few keV/u highly charged ions for atomic physics experiments. The expected beam intensity is up to 105 ions per shot. To optimize phase and amplitude of the RF systems intensity, bunch length and kinetic energy of the particles need to be monitored. The bunch length that we need to fit is about 2 ns, which is typically measured by capacitive pickups. However, they do not work for the low beam intensities that we face. We investigated the bunch length with a fast CVD diamond detector working in single particle counting mode. Averaging over 8 shots yields a clear, regular picture of the bunched beam. Energy measurements by capacitive pickups are limited by the presence of intense primary and partially decelerated beam and hence make tuning of the IH-structure impossible. The energy of the decelerated fraction of the beam behind the first deceleration cavity was determined to about 10 % accuracy with a permanent dipole magnet combined with a MCP. Better detector calibration should help reaching the required 1%. Design of the detectors as well as the results of the measurements will be presented.
The development of a non- destructive measurement method for ion beam parameters has been treated in various projects. Although results are promising, the high complexity of beam dynamics has made it impossible to implement a real time process control up to now. In this paper we will propose analysing methods based on the dynamics of Cellular Nonlinear Networks (CNN) that can be implemented on pixel parallel CNN based architectures and yield satisfying results even at low resolutions.
In case of 4-Rod-type RFQ’s the quadrupole electrodes are excited by a series of coupled RF oscillators. As the contact planes between both electrode pairs differ, there remains an oscillating electric potential along the beam axis. This results in remarkably high longitudinal field components between the electrode ends and the RFQ tank end walls. In contrast, the electrodes of a 4-Vane RFQ are equally charged to ±|V0∕2| and only feature a quadrupole on-axis field. The entrance gap fields were investigated to serve as a longitudinal prebuncher instead of causing additional longitudinal emittance growth. The effects of the entrance gap field have been validated in beam dynamics simulations. The exit fields have to be taken into consideration for a calculation of the exact RFQ output energy.
Based on the positive results of the 0.63 m unmodulated 325 MHz Ladder-RFQ prototype from 2013 to 2016 [1, 2], a modulated 3.3m Ladder-RFQ (s. Fig. 1) has been designed and built for the acceleration of up to 100 mA protons from 95 keV to 3.0 MeV at the FAIR p-Linac [3, 4]. In this paper, we will show the results of manufacturing as well as low level RF measurements of the Ladder-RFQ including flatness and frequency tuning.
Space charge lenses use a confined electron cloud for the focusing of ion beams. The focusing strength is given by the electron density whereas the density distribution influences the mapping quality of the space charge lens and is related to the confinement. The plasma parameters, loss as well as production mechanisms have a strong impact on plasma beam interactions. A scaled up space charge lens was constructed to investigate the properties of a nonneutral plasmas in detail. New non-interceptive diagnostic has been developed to characterize the collective behaviour of the confined nonneutral plasma in terms of an optimized lens design and parameters. Experimental results will be presented in comparison with numerical simulations.
Space charge lenses using a stable electron cloud for focusing low energy heavy ion beams are an alternative concept to conventional ion optics. Due to external fields electrons are confined inside the lens’ volume. In case of a homogeneously distributed electron cloud the linear electric space charge field enables beam focusing free of aberration. Since the mapping quality of the lens is related to the confinement, non-destructive diagnostics has been developed to determine the plasma parameters and to characterize the collective behavior of the confined nonneutral plasma. Moreover, a scaled up space charge lens was constructed for a detailed investigation of the nonneutral plasma properties as well as beam interactions with a stable confined electron cloud. Experimental results will be presented in comparison with numerical simulations.