Refine
Year of publication
Document Type
- Preprint (576)
- Article (368)
- Conference Proceeding (4)
Has Fulltext
- yes (948)
Is part of the Bibliography
- no (948)
Keywords
- Heavy Ion Experiments (18)
- Hadron-Hadron scattering (experiments) (11)
- LHC (10)
- Heavy-ion collision (6)
- ALICE experiment (4)
- Hadron-Hadron Scattering (4)
- Heavy Ions (4)
- Quark-Gluon Plasma (4)
- ALICE (3)
- Jets and Jet Substructure (3)
Institute
- Physik (928)
- Frankfurt Institute for Advanced Studies (FIAS) (854)
- Informatik (820)
- Medizin (17)
- Informatik und Mathematik (3)
- Hochschulrechenzentrum (2)
- Biochemie und Chemie (1)
- Erziehungswissenschaften (1)
Die Zunahme an Gewalttaten, insbesondere durch Kinder und Jugendliche, wird in der öffentlichen und pädagogischen Diskussion weithin beklagt. Zwar zeigen zeitvergleichende Analysen, dass von einer dramatischen Erhöhung der Gewalhandlungen keine Rede sein kann; eher ist die öffentliche Sensibilität für derartige Vorfälle gestiegen. Andererseits gibt es erschreckende Beispiele für besonders brutale Übergriffe, die im öffentlichen Bewusstsein naturgemäß dominieren. Eindeutig zugenommen haben in den letzten Jahren politisch motivierte Gewalttaten, insbesondere mit rechtsextremistischem Hintergrund. Doch unabhängig davon, ob und wo die Zahl der Gewalthandlungen angestiegen ist, beinhaltet jede einzelne Tat einen Angriff auf die Menschenwürde und die politische Kultur und ruft deshalb nach Gegenmaßnahmen.
Hypersecretion and chronic phlegm are major symptoms of chronic obstructive pulmonary disease (COPD) but animal models of COPD with a defined functional hypersecretion have not been established so far. To identify an animal model of combined morphological signs of airway inflammation and functional hypersecretion, rats were continuously exposed to different levels of sulfur dioxide (SO2, 5 ppm, 10 ppm, 20 ppm, 40 ppm, 80 ppm) for 3 (short-term) or 20–25 (long-term) days. Histology revealed a dose-dependent increase in edema formation and inflammatory cell infiltration in short-term-exposed animals. The submucosal edema was replaced by fibrosis after long-term-exposure. The basal secretory activity was only significantly increased in the 20 ppm group. Also, stimulated secretion was significantly increased only after exposure to 20 ppm. BrdU-assays and AgNOR-analysis demonstrated cellular metaplasia and glandular hypertrophy rather than hyperplasia as the underlying morphological correlate of the hypersecretion.
In summary, SO2-exposure can lead to characteristic airway remodeling and changes in mucus secretion in rats. As only long-term exposure to 20 ppm leads to a combination of hypersecretion and airway inflammation, only this mode of exposure should be used to mimic human COPD. Concentrations less or higher than 20 ppm or short term exposure do not induce the respiratory symptom of hypersecretion. The present model may be used to characterize the effects of new compounds on mucus secretion in the background of experimental COPD.
Background: Platelet activating factor and tachykinins (substance P, neurokinin A, neurokinin B) are important mediators contributing to increased airway secretion in the context of different types of respiratory diseases including acute and chronic asthma. Leukotriene receptor antagonists are recommended as add-on therapy for this disease. The cys-leukotriene-1 receptor antagonist montelukast has been used in clinical asthma therapy during the last years. Besides its inhibitory action on bronchoconstriction, only little is known about its effects on airway secretions. Therefore, the aim of this study was to evaluate the effects of montelukast on platelet activating factor- and tachykinin induced tracheal secretory activity.
Methods: The effects of montelukast on platelet activating factor- and tachykinin induced tracheal secretory activity in the rat were assessed by quantification of secreted 35SO4 labelled mucus macromolecules using the modified Ussing chamber technique.
Results: Platelet activating factor potently stimulated airway secretion, which was completely inhibited by the platelet activating factor receptor antagonist WEB 2086 and montelukast. In contrast, montelukast had no effect on tachykinin induced tracheal secretory activity.
Conclusion: Cys-leukotriene-1 receptor antagonism by montelukast reverses the secretagogue properties of platelet activating factor to the same degree as the specific platelet activating factor antagonist WEB 2086 but has no influence on treacheal secretion elicited by tachykinins. These results suggest a role of montelukast in the signal transduction pathway of platelet activating factor induced secretory activity of the airways and may further explain the beneficial properties of cys-leukotriene-1 receptor antagonists.
The supersilylated ethene trans-(tBu3Si)HC=CH(SitBu3) (triclinic, P ī) is accessible from the reaction of tBu3SiCHBr2 with nBuLi at −78 °C in THF or Et2 O. The reaction of Li(H2NCH2CH2NH2)C≡CH with tBu3SiBr leads to the formation of (tBu3Si)C≡CH and (tBu3Si)C≡C(SitBu3). X-Ray quality crystals of (tBu3Si)C≡C(SitBu3) (triclinic, P ī) were obtained by recrystallization from hexane. In contrast to the structures of the disilane tBu3Si-SitBu3 and the disiloxane tBu3Si-O-SitBu3, the sterically crowded ethene trans-(tBu3Si)HC=CH(SitBu3) and ethyne (tBu3Si)C≡C(SitBu3) feature dihedral angles of 60° in the solid-state structures.
Due to an increasing awareness of the potential hazardousness of air pollutants, new laws, rules and guidelines have recently been implemented globally. In this respect, numerous studies have addressed traffic-related exposure to particulate matter using stationary technology so far. By contrast, only few studies used the advanced technology of mobile exposure analysis. The Mobile Air Quality Study (MAQS) addresses the issue of air pollutant exposure by combining advanced high-granularity spatial-temporal analysis with vehicle-mounted, person-mounted and roadside sensors. The MAQS-platform will be used by international collaborators in order 1) to assess air pollutant exposure in relation to road structure, 2) to assess air pollutant exposure in relation to traffic density, 3) to assess air pollutant exposure in relation to weather conditions, 4) to compare exposure within vehicles between front and back seat (children) positions, and 5) to evaluate "traffic zone"- exposure in relation to non-"traffic zone"-exposure. Primarily, the MAQS-platform will focus on particulate matter. With the establishment of advanced mobile analysis tools, it is planed to extend the analysis to other pollutants including including NO2, SO2, nanoparticles, and ozone.
The first measurement of two-pion Bose–Einstein correlations in central Pb–Pb collisions at √sNN=2.76 TeV at the Large Hadron Collider is presented. We observe a growing trend with energy now not only for the longitudinal and the outward but also for the sideward pion source radius. The pion homogeneity volume and the decoupling time are significantly larger than those measured at RHIC.
Inclusive transverse momentum spectra of primary charged particles in Pb–Pb collisions at √sNN=2.76 TeV have been measured by the ALICE Collaboration at the LHC. The data are presented for central and peripheral collisions, corresponding to 0–5% and 70–80% of the hadronic Pb–Pb cross section. The measured charged particle spectra in |η|<0.8 and 0.3<pT<20 GeV/c are compared to the expectation in pp collisions at the same sNN, scaled by the number of underlying nucleon–nucleon collisions. The comparison is expressed in terms of the nuclear modification factor RAA. The result indicates only weak medium effects (RAA≈0.7) in peripheral collisions. In central collisions, RAA reaches a minimum of about 0.14 at pT=6–7 GeV/c and increases significantly at larger pT. The measured suppression of high-pT particles is stronger than that observed at lower collision energies, indicating that a very dense medium is formed in central Pb–Pb collisions at the LHC.
The inclusive charged particle transverse momentum distribution is measured in proton–proton collisions at s=900 GeV at the LHC using the ALICE detector. The measurement is performed in the central pseudorapidity region (|η|<0.8) over the transverse momentum range 0.15<pT<10 GeV/c. The correlation between transverse momentum and particle multiplicity is also studied. Results are presented for inelastic (INEL) and non-single-diffractive (NSD) events. The average transverse momentum for |η|<0.8 is 〈pT〉INEL=0.483±0.001 (stat.)±0.007 (syst.) GeV/c and 〈pT〉NSD=0.489±0.001 (stat.)±0.007 (syst.) GeV/c, respectively. The data exhibit a slightly larger 〈pT〉 than measurements in wider pseudorapidity intervals. The results are compared to simulations with the Monte Carlo event generators PYTHIA and PHOJET.
A test stand for optical beam tomography was developed. As a new non-destructive beam-diagnostic system for high current ion beams, the test stand will be installed in the low energy beam transport section (LEBT) of the Frankfurt Neutron Source (FRANZ) behind the chopper system. The test stand consists of a rotatable vacuum chamber with a mounted CCD camera. The maximum rotation angle amounts to 270°. In a first phase the optical beam profile measurement and 3D density reconstruction is tested with a time independent 10 keV He beam. The measurements and performance of data processing algorithms are compared with the beam transport simulations. In a later phase the performance with time dependent beams (120 keV, 200 mA) at a repetition rate of 250 kHz and a duty cycle of 2.5% has to be evaluated. An overview of the first phase results is shown.
A non-interceptive optical diagnostic system on the basis of beam tomography, was developed for the planned Frankfurt Neutron Source (FRANZ). The proton driver linac of FRANZ will provide energies up to 2.0 MeV. The measurement device will non-interceptively derive required beam parameters at the end of the LEBT at beam energies of 120 keV and a current of 200 mA. On a narrow space of 351.2 mm length a rotatable tomography tank will perform a multi-turn tomography with a high and stable vacuum pressure. The tank allows to plug different measurement equipment additionally to the CCD Camera installed, to perform optical beam tomography. A collection of developed algorithms provides information about the density distribution, shape, size, location and emittance on the basis of CCD images. Simulated, as well as measured data have been applied to the evaluation algorithms to test the reliability of the beam. The actual contribution gives an overview on the current diagnostic possibilities of this diagnostic system.