Refine
Year of publication
Document Type
- Article (31)
- Preprint (2)
- Conference Proceeding (1)
Language
- English (34) (remove)
Has Fulltext
- yes (34)
Is part of the Bibliography
- no (34)
Keywords
- Herb induced liver injury (2)
- Actaea cimicifuga (1)
- Artendiversität (1)
- Berci needle (1)
- Black cohosh (1)
- Black cohosh induced liver injury (1)
- Buchenwald (1)
- Causality assessment (1)
- Charged-particle density (1)
- Cognitive impairment (1)
Institute
- Medizin (14)
- Physik (12)
- Frankfurt Institute for Advanced Studies (FIAS) (7)
- Informatik (5)
- Biowissenschaften (2)
- Biochemie und Chemie (1)
- ELEMENTS (1)
- Geowissenschaften (1)
Rationale: Potassium (K) is a major component of several silicate minerals and seawater, and, therefore, constraining past changes in the potassium cycle is a promising way of tracing large-scale geological processes on Earth. However, [K] measurement using inductively coupled plasma mass spectrometry (ICP-MS) is challenging due to an ArH+ interference, which may be of a similar magnitude to the K+ ion beam in samples with <0.1% m/m [K].
Methods: In this work, we investigated the effect of the ArH+ interference on K/Ca data quality by comparing results from laser-ablation (LA)-ICP-MS measured in medium and high mass resolution modes and validating our LA results via solution ICP-optical emission spectroscopy (OES) and solution ICP-MS measurements. To do so, we used a wide range of geological reference materials, with a particular focus on marine carbonates, which are potential archives of past changes in the K cycle but are typically characterised by [K] < 200 μg/g. In addition, we examine the degree to which trace-element data quality is driven by downhole fractionation during LA-ICP-MS measurements.
Results: Our results show that medium mass resolution (MR) mode is sufficiently capable of minimising the effect of the ArH+ interference on K+. However, the rate of downhole fractionation for Na and K varies between different samples as a result of their differing bulk composition, resulting in matrix-specific inaccuracy. We show how this can be accounted for via downhole fractionation corrections, resulting in an accuracy of better than 1% and a long-term reproducibility (intermediate precision) of <6% (relative standard deviation) in JCp-1NP using LA-ICP-MS in MR mode.
Conclusion: Our [K] measurement protocol is demonstrably precise and accurate and applicable to a wide range of materials. The measurement of K/Ca in relatively low-[K] marine carbonates is presented here as a key example of a new application opened up by these advances.
This paper reports on Monte Carlo simulation results for future measurements of the moduli of time-like proton electromagnetic form factors, |GE | and |GM|, using the ¯pp → μ+μ− reaction at PANDA (FAIR). The electromagnetic form factors are fundamental quantities parameterizing the electric and magnetic structure of hadrons. This work estimates the statistical and total accuracy with which the form factors can be measured at PANDA, using an analysis of simulated data within the PandaRoot software framework. The most crucial background channel is ¯pp → π+π−,due to the very similar behavior of muons and pions in the detector. The suppression factors are evaluated for this and all other relevant background channels at different values of antiproton beam momentum. The signal/background separation is based on a multivariate analysis, using the Boosted Decision Trees method. An expected background subtraction is included in this study, based on realistic angular distribuations of the background contribution. Systematic uncertainties are considered and the relative total uncertainties of the form factor measurements are presented.
Measurements of the π±, K±, and proton double differential yields emitted from the surface of the 90-cm-long carbon target (T2K replica) were performed for the incoming 31 GeV/c protons with the NA61/SHINE spectrometer at the CERN SPS using data collected during 2010 run. The double differential π± yields were measured with increased precision compared to the previously published NA61/SHINE results, while the K± and proton yields were obtained for the first time. A strategy for dealing with the dependence of the results on the incoming proton beam profile is proposed. The purpose of these measurements is to reduce significantly the (anti)neutrino flux uncertainty in the T2K long-baseline neutrino experiment by constraining the production of (anti)neutrino ancestors coming from the T2K target.
No association between Parkinson disease and autoantibodies against NMDA-type glutamate receptors
(2019)
Background: IgG-class autoantibodies to N-Methyl-D-Aspartate (NMDA)-type glutamate receptors define a novel entity of autoimmune encephalitis. Studies examining the prevalence of NMDA IgA/IgM antibodies in patients with Parkinson disease with/without dementia produced conflicting results. We measured NMDA antibodies in a large, well phenotyped sample of Parkinson patients without and with cognitive impairment (n = 296) and controls (n = 295) free of neuropsychiatric disease. Detailed phenotyping and large numbers allowed statistically meaningful correlation of antibody status with diagnostic subgroups as well as quantitative indicators of disease severity and cognitive impairment.
Methods: NMDA antibodies were analysed in the serum of patients and controls using well established validated assays. We used anti-NMDA antibody positivity as the main independent variable and correlated it with disease status and phenotypic characteristics.
Results: The frequency of NMDA IgA/IgM antibodies was lower in Parkinson patients (13%) than in controls (22%) and higher than in previous studies in both groups. NMDA IgA/IgM antibodies were neither significantly associated with diagnostic subclasses of Parkinson disease according to cognitive impairment, nor with quantitative indicators of disease severity and cognitive impairment. A positive NMDA antibody status was positively correlated with age in controls but not in Parkinson patients.
Conclusion: It is unlikely albeit not impossible that NMDA antibodies play a significant role in the pathogenesis or progression of Parkinson disease e.g. to Parkinson disease with dementia, while NMDA IgG antibodies define a separate disease of its own.
The Transition Radiation Detector (TRD) was designed and built to enhance the capabilities of the ALICE detector at the Large Hadron Collider (LHC). While aimed at providing electron identification and triggering, the TRD also contributes significantly to the track reconstruction and calibration in the central barrel of ALICE. In this paper the design, construction, operation, and performance of this detector are discussed. A pion rejection factor of up to 410 is achieved at a momentum of 1 GeV/c in p-Pb collisions and the resolution at high transverse momentum improves by about 40% when including the TRD information in track reconstruction. The triggering capability is demonstrated both for jet, light nuclei, and electron selection.
Purpose: The aim of this official guideline coordinated and published by the German Society for Gynecology and Obstetrics (DGGG) and the German Cancer Society (DKG) was to optimize the screening, diagnosis, therapy and follow-up care of breast cancer.
Methods: The process of updating the S3 guideline dating from 2012 was based on the adaptation of identified source guidelines which were combined with reviews of evidence compiled using PICO (Patients/Interventions/Control/Outcome) questions and the results of a systematic search of literature databases and the selection and evaluation of the identified literature. The interdisciplinary working groups took the identified materials as their starting point to develop recommendations and statements which were modified and graded in a structured consensus procedure.
Recommendations: Part 1 of this short version of the guideline presents recommendations for the screening, diagnosis and follow-up care of breast cancer. The importance of mammography for screening is confirmed in this updated version of the guideline and forms the basis for all screening. In addition to the conventional methods used to diagnose breast cancer, computed tomography (CT) is recommended for staging in women with a higher risk of recurrence. The follow-up concept includes suggested intervals between physical, ultrasound and mammography examinations, additional high-tech diagnostic procedures, and the determination of tumor markers for the evaluation of metastatic disease.
We present measurements of ρ0, ω and K∗0 spectra in π−+ C production interactions at 158 GeV / c and ρ0 spectra at 350 GeV / c using the NA61/SHINE spectrometer at the CERN SPS. Spectra are presented as a function of the Feynman’s variable xF in the range 0<xF<1 and 0<xF<0.5 for 158 and 350 GeV / c respectively. Furthermore, we show comparisons with previous measurements and predictions of several hadronic interaction models. These measurements are essential for a better understanding of hadronic shower development and for improving the modeling of cosmic ray air showers.