Heute gewinnen pflanzliche Arzneimittel im Zeichen einer verstärkten Hinwendung zu natürlichen, relativ nebenwirkungsarmen Medikamenten zunehmend an Bedeutung, so auch die über Jahrtausende hinweg traditionell angewandte Ginsengwurzel (Panax ginseng) und der Indische Weihrauch (Boswellia serrata). Neben der Struktur- und Extraktanalytik konzentriert sich die Forschung in zunehmenden Maße darauf, die zahlreichen pharmakologisch untersuchten und klinisch beobachteten Wirkungen dieser beiden Arzneipflanzen einzelnen Inhaltsstoffen zuzuordnen. Bei der Ginsengwurzel gestaltet sich dies jedoch besonders schwierig. Dies ist begründet durch die große Anzahl strukturell ähnlicher Ginsenoside sowie durch deren unterschiedlicher Metabolismus. Zwar ist aus In-vitro-Experimenten bekannt, daß die Degradation über die stufenweise Deglukosylierung stattfindet, allerdings ist bislang nicht geklärt, ob intakte Ginsenoside überhaupt resorbiert werden und welche der vielen in vitro ermittelten Degradationsprodukte tatsächlich den systemischen Kreislauf erreichen. Anders als bei Ginseng, kann die therapeutische Wirkung des Indischen Weihrauches wohl definierten Inhaltsstoffen, AKBA und KBA, zugeschrieben werden. Dennoch mangelt es hier an verlässlichen pharmakokinetischen Daten, da bislang keine validierte bioanalytische Methode zur Verfügung stand. Im Rahmen der Bioanalytik von Ginsenosiden und Boswellliasäuren kamen in der vorliegenden Arbeit die Nano-ESI-MS(n)-Technik sowie die HPLC-Analytik zur Anwendung. Bereits bei der Strukturanalyse von Ginsenosiden erwies sich die Kombination der Nano-ESI-Technik mit MS(n)-Experimenten in einer Quadrupol-Ionenfalle als besonders vorteilhaft. Im Vergleich zu konventionellem ESI bietet Nano-ESI nicht nur den Vorzug, mit kleinsten Substanzmengen lange Messungen durchführen zu können, sondern auch den Vorteil einer effektiveren, weniger diskreminierenden Ionisation. Sowohl die hohe Sensitivität der Nano-Elektrosprayionisierung bei der Analyse von glykosidischen Verbindungen als auch die umfangreichen Strukturinformationen infolge mehrerer aufeinanderfolgender stoßinduzierter Fragmentierungen machen diese Technik zu einer attraktiven und effizienten Methode zur Analyse von Ginsenosiden. In MS(n)-Experimenten äußert sich das charakteristische Fragmentierungsverhalten der Ginsenoside in der sequentiellen Abspaltung der Zuckereinheiten in sukkzessiven Fragmentierungsschritten. Mit dieser Methode konnten die Zuckerketten an verschiedenen Positionen des Protopanaxadiol- bzw. Protopanaxatriolaglykons der Ginsenoside identifiziert, die glykosidischen Verknüpfungen innerhalb der einzelnen Zuckereinheiten durch spezifische Ringfragmente bestimmt und die genaue(n) Verknüpfungsposition(en) enzymatisch eingeführter Galaktose(n) lokalisiert werden. Bisher wurden allerdings Nano-ESI-MS/MS bzw. MS(n)-Untersuchungen primär an wässrigen oder organischen Lösungen von isolierten / aufgereinigten Stoffen oder Stoffgemischen durchgeführt. In dieser Arbeit wurde erstmals diese Technik in der Bioanalytik zur Identifizierung von Ginsenosiden und deren Degradationsprodukte in Humanplasma und -urin angewandt. Obwohl die optimale Analytkonzentration für die Nano-Elektrosprayionisierung im allgemeinen bei 10-5M liegt, ist es gelungen, die Ginsenoside anhand ihrer spezifischen Fragmentionen im MS/MS Modus bis zu einer Konzentration von 2 ng/mL (10-8M) in biologischen Matrices nachzuweisen. Auch wenn die Molekülionenpeaks bei diesen geringen Konzentrationen im Rauschen untergehen, können die Ginsenoside durch selektive Isolierung der gewünschten Vorläuferionen und deren anschließende Fragmentierung in der Quadrupol-Ionenfalle auf der Basis der Detektion spezifischer Fragmente identifiziert werden. Da bei der Fragmentierung der gleichen Vorläuferionenmasse in Leerplasma bzw. Urin keine charakteristischen Fragmentionen gebildet werden, handelt es sich somit um einen spezifischen Nachweis der Ginsenoside in biologischen Matrices. Vor dem Hintergrund dieser vielversprechenden Vorversuche wurde eine Pilotstudie zum qualitativen Screening von Ginsenosiden und deren Metaboliten in Humanplasma und –urin durchgeführt. Es konnte gezeigt werden, daß Protopanaxatriol-Ginsenoside sowohl im Magen hydrolysiert als auch intestinal degradiert werden. Schon in den ersten Stunden nach der einmaligen oralen Einnahme von Ginsana G115 Kapseln wurden die Hydrolyseprodukte G-Rh1 und hydratisiertes G-Rh1 in Humanplasma detektiert. Die schnelle Resorption dieser beiden Verbindungen aus dem oberen Gastrointestinaltrakt deutet auf die Hydrolyse des Ginsenosides Rg1 im Magen hin. Das spätere Auftreten eines weiteren monoglukosylierten Protopanaxatriols, des Degradationsproduktes G-F1, liefert den ersten In-Vivo-Hinweis auf einen intestinalen Metabolismus von Protopanaxatriol-Ginsenoside. Im Gegensatz zu den Protopanaxatriolginsenosiden passieren die Protopanaxadiol-Ginsenoside den Magen unverändert, wie aus der Abwesenheit jeglicher Protopanaxadiol-Degradationsprodukte im Plasma und Urin in den ersten Stunden nach der Applikation geschlossen werden kann. Erst im unteren Gastrointestinaltrakt werden Protopanaxadiol-Ginsenoside durch intestinale Bakterien zu „Compound-K“ abgebaut und anschließend resorbiert. Der Nachweis von Ginsenosid Rb1 im Plasma, sowie weiterer Ginsenoside im Urin eines Probanden zeigt, daß auch Ginsenoside in ihrer intakten Form resorbiert werden können. Dennoch sind weitere Studien hierzu notwendig, um zu klären, ob die Resorption intakter Ginsenoside die Regel oder eher eine Ausnahme darstellt. Mit der Identifizierung des Hydrolyseproduktes G-Rh1, der Degradationsprodukte G-F1 sowie „Compound-K“ in Humanplasma und -urin konnte schließlich die Frage geklärt werden, welche der zahlreichen in vitro bestimmten Degradationsprodukte tatsächlich den systemischen Kreislauf erreichen. Damit ist die Basis für eine spätere Quantifizierung dieser Verbindungen nach ihrer Isolierung bzw. Herstellung und Charakterisierung als Referenzsubstanzen geschaffen. Außerdem können diese neuen Erkenntnisse helfen, pharmakologische Ergebnisse aus In-vitro-Versuchen mit In-vivo-Daten besser zu korrelieren, da sie erste Hinweise geben, welche der in vitro getesteten Substanzen für die in vivo beobachteten Effekte verantwortlich sein könnten. Bisher wurde Nano-ESI-MS(n) in der Bioanalytik pflanzlicher Arzneistoffe nicht eingesetzt. In dieser Arbeit wurde diese Technik erstmals zum Screening von Ginsenosiden und deren Degradationsprodukte in Humanplasma und –urin benutzt. Darüber hinaus konnte gezeigt werden, daß Nano-ESI-MS(n) auch eine empfindliche und sensitive Methode zur Identifizierung und zum Nachweis anderer medizinisch relevanter glykosidischer Verbindungen in biologischen Matrices darstellt, woraus sich neue Perspektiven für den Einsatz dieser Technik in der Metabolitenforschung sowie in der Bioanalytik pflanzlicher Xenobiotika ergeben. In den letzten Jahren rückte auch der Indische Weihrauch immer mehr in den Mittelpunkt des wissenschaftlichen sowie therapeutischen Interesses. Aufgrund der selektiven Hemmung der 5-Lipoxygenase gewinnen AKBA und KBA, als neue entzündungshemmende Verbindungen, zunehmend an Bedeutung. Während die quantitative Analytik der Boswelliasäuren in Extrakten und in verschiedenen Fertigarzneimitteln erhebliche Fortschritte erzielen konnte, fehlten auf dem Gebiet der Bioanalytik bislang validierte analytische Methoden zur Durchführung pharmakokinetischer Studien. Vor diesem Hintergrund wurde eine HPLC-Methode zur Bestimmung von KBA in Humanplasma entwickelt und validiert. Die Methode ist durch eine einfache Probenvorbereitung gekennzeichnet, die sich auf eine Festphasenextraktion der KBA aus der komplex zusammengesetzten biologischen Matrix beschränkt. Im Anschluß an die chromatographische Trennung auf einer RP-C18 Säule erfolgt die Quantifizierung der KBA mittels UV-Detektion bei 250 nm. Um eine adäquate Bestimmung der KBA in Humanplasma zu gewährleisten, wurde eine umfassende Validierung durchgeführt. Alle ermittelten Validierungsparameter, wie Spezifität, Linearität, Präzision, Richtigkeit, Reproduzierbarkeit, untere Quantifizierungsgrenze und Stabilität lagen innerhalb der vorgegebenen Grenzen. Damit erfüllt die entwickelte HPLC-Methode die allgemein gültigen Anforderungen an die Validierung bioanalytischer Methoden. Mit der Erstellung einer Plasmakonzentrations-Zeit-Kurve im Rahmen einer ersten Pilotstudie konnte diese Methode zudem ihre praktische Anwendbarkeit unter Beweis stellen. Somit steht für zukünftige pharmakokinetische Studien eine validierte HPLC-Analytik zur Bestimmung von KBA, einer der Hauptwirkstoffe des Indischen Weihrauches, zur Verfügung, die sich durch hohe Spezifität, Reproduzierbarkeit und Präzision auszeichnet. Verlässliche Daten zur Pharmakokinetik am Menschen sind heute von besonderer Bedeutung, da sie helfen, die Dosierung zu optimieren, die biopharmazeutischen Eigenschaften von Präparaten zu verbessern und die Sicherheit bei der Anwendung zu erhöhen. Insbesondere im Hinblick auf bereits festgestellte Interaktionen von pflanzlichen Arzneimitteln mit Medikamenten reicht es nicht mehr aus, wenn sich pflanzliche Arzneimittel, wie beispielsweise Ginseng und Indischer Weihrauch, nur auf ihre langjährigen tradierten Anwendungserfahrungen berufen. So wird auch bei Phytopharmaka in verstärktem Maße eine wissenschaftliche Absicherung durch bioanalytische Forschung erwartet. Mit der Identifizierung der Ginsenoside und deren Degradationsprodukte im Menschen, der erstmaligen Anwendung von Nano-ESI-MS(n) in der Metabolitenforschung und der Entwicklung einer validierten bioanalytischen Methode zur Bestimmung der 11-Keto-Beta-Boswelliasäure in Humanplasma wurde diesen Erfordernissen Rechnung getragen.
Seit der erstmaligen Beschreibung der MALDI (Matrix-Assisted-Laser-Desorption/Ionisation) durch Michael Karas und Franz Hillenkamp, welche die massenspektrometrische Analyse auch großer Proteine über 100 kDa erlaubt, fand diese Technik sowohl unter den Massenspektrometrie-Gruppen als auch in Biochemischen Laboratorien rasche Verbreitung. MALDI kann inzwischen auf eine breite Palette von Biomolekülen angewendet werden und stellt heute - neben Elektrospray (ESI) -eine der beiden gebräuchlichsten massenspektrometrischen Methoden überhaupt dar. In ähnlicher Weise erlangte das Gebiet der Proteomics, der "systematischen Erforschung der zahlreichen und unterschiedlichsten Eigenschaften von Proteinen in paralleller Weise mit der Zielsetzung einer detaillierten Beschreibung der Struktur, Funktion und Steuerung biologischer Systeme im gesunden und krankhaften Zustand" eine Schlüsselstellung in der Biologie und damit einen erheblichen Einfluss auf alle Gebiete der Biologie, der Pharmazie und medizinisch verwandter Bereiche. In der Tat sind Proteine an allen biologischen Aktivitäten beteiligt und weisen die vielfaltigsten Eigenschaften auf, die in ihrer Gesamtheit zu unserem Verständnis biologischer Systeme beitragen. Die systematische Untersuchung dieser Eigenschaften macht das Gebiet der Proteomics aus und beinhaltet die Erforschung der Sequenz, Menge, Modifikationen, Wechselwirkungen mit anderen Proteinen, der biologischen Aktivität, sub-zellulären Verteilung und dreidimensionalen Struktur. .... Letztlich wäre es für den Analytiker wünschenswert, aiie Schritte der MS-basierten Proteomics im Detail zu verstehen und damit vollständig zu beherrschen. Im Rahmen der vorliegenden Arbeit wurden deshalb die drei entscheidenden Probenvorbereitungsschritte der MALDI-MS - gestützten Pmteomics näher untersucht. Proteinverdau: Der gebräuchliche Ansatz der MS-basierten Proteomics beinhaltet im ersten Schritt den (enzymatischen) Verdau der Proteinprobe, meist mit Trypsin aufgrund seiner sauber definierten Schnittstellen auf der C-terminalen Seite der basischen Aminosäuren Arginin (R) und Lysin (K) bei pH um 8. Dazu wurden in den vergangenen Jahrzehnten etliche Protokolle entwickelt, die auf eine möglichst vollständige Proteolyse und damit hohe Ausbeute an Spaltpeptiden abzielen. Probenaufreinigung: Als Bindeglied zwischen Proteinisolierung und MS-Analyse kommt der Aufieinigung des beim Verdau anfallenden Peptidgemischs entscheidende Bedeutung zu, da die Reinheit der Proben letzten Endes ausschlaggebend für die Qualität der Spektren ist. Auch hier sind kontinuierliche Anstrengungen zur Verbesserung im Gange, wobei in den letzten Jahren insbesondere auch spezielle Aufreinigungsmethoden für den Mikro-Maßstab beschrieben wurden, die den Bedürfnissen der Proteomics besonders entgegenkommen. Probenpräparation: Der letzte entscheidende Schritt vor der MALDI-Analyse besteht im ,,Spotting", dem Auftrag der zu analysierenden Probe zusammen mit der Matrix und deren Co-Kristallisation auf dem Probenteller. Hier bestimmen u.a. die Wahl der Matrix, der verwendeten Lösungsmittel sowie die Zugabe verschiedener Additive das Ergebnis. Obwohl der Einfluss der Matrix und Additiven auf den Desorptionsprozess einleuchtend und aus empirischen Erfahrungen seit langem bekannt ist, fehlt einem rationalen Vorgehen hier insofern die Grundlage, als dass leider noch immer kein Desorptions- und Ionisationsmechanismus gesichert ist. .... Zusammenfassend ist festzuhalten, dass die vorliegenden Untersuchungen viele interessante Details und neue Ideen lieferten, die zur Verbesserung der MALDI-TOF-Analytik bei Proteomics beitragen können, so etwa: - die Portierung der einfachen, schnelle und preiswerten Probenaufreinigung mittels PVDF- und Nitrozellulosemembranen auf titerplattenbasierte Robotersysteme, bei denen eine automatisierte Zugabe der geeigneten Membranstücke, gefolgt von einfachen Wasch- und Extraktions-Schritten das Probenhandling wesentlich erleichtern sollten, - eine mögliche Verbesserung der Proteinidentifizierung durch Selektion eher hydrophiler Peptide durch neue Materialien wie HILIC, da die Mehrzahl der zur herangezogenen Peptide eher hydrophoben Charakter besitzt, - die weitere Verwendung und Erweiterung der im Rahmen dieser Arbeit erstellten Datenbanken zur Aufklärung der Zusammenhänge zwischen Peptidsequenz, der damit verbundenen physikochemischen Eigenschaften und Selektivitäts- / Unterdrückungseffekten bei der MALDI-MS.
Das Ziel der vorliegenden Arbeit war es, MALDI-Massenspektrometrie als robuste Analysenmethode für die quantitative Analyse niedermolekularer Verbindungen aus komplexen biologischen Matrizes zu etablieren. Zu Beginn der Arbeit wurden drei typische Fragestellungen im Bereich der Lebensmittelanalytik, der medizinischen Forschung und der klinischen Chemie ausgewählt, um die Methodik anhand dieser Modellsysteme zielgerichtet zu entwickeln und zu bewerten. Für jede dieser Fragestellungen wird routinemäßig ein hoher Probendurchsatz verlangt und damit werden hohe Anforderungen an die Probenvorbereitung gestellt, da diese einfach, schnell, reproduzierbar, Matrix-tolerant und automatisierbar sein muss um die Weiterentwicklung zur Hochdurchsatzanalytik zu erlauben.
Der quantitative Nachweis von Melamin und seinen Derivaten wurde aufgrund des Aufkommens von Milchprodukten, die mit diesen Verbindungen kontaminiert waren, ein wichtiger Bestandteil der Analytik dieser Lebensmittel. Insbesondere an diesem Beispiel zeigte sich der Vorteil des Einsatzes von MALDI-Massenspektrometrie zur Analyse kleiner Moleküle. Aufgrund der höheren Toleranz gegenüber Puffern und Salzen konnte die Probenvorbereitungszeit der für die FDA entwickelten Methode zur Quantifizierung von Melamin in Milchpulver mittels LC-ESI von ca. 140 min auf 90 min reduziert werden, da auf die zeitaufwendige Flüssigchromatographie verzichtet werden konnte. So wurde Melamin mit einem LLOQ von 0,5 ppm quantifiziert, was unterhalb der Vorgaben der WHO (2,5 ppm in Milichpulver und 1 ppm in Babynahrung) lag. Cyanursäure, ein Derivat von Melamin welches für die Bildung schwerlöslicher Komplexe in der Niere mitverantwortlich gemacht wird, konnte ebenfalls mit der entwickelten MALDI-MS Methode quantifiziert werden. Allerdings war die ermittelte Bestimmungsgrenze mit 15 ppm um den Faktor 30 schlechter als bei Melamin. Die Nachweisgrenze bei MALDI-MS ist stark von der MALDI-Matrix abhängig und die Verwendung von Sinapinsäure war eine gute Kompromisslösung, um die Analyten in einem Spot im positiven und negativen Reflektormodus zu analysieren. Allerdings wurde diese Matrix zur Analyse von Analyten im positiven Reflektormodus entwickelt. Bislang wurden nur wenige Matrizes für MALDI-MS im negativen Reflektormodus beschrieben, um z.B. Säuren besser nachweisen zu können. Forschung in diesem Bereich wird neue Möglichkeiten zur Detektion negativ geladener kleiner Moleküle ergeben.
Des Weiteren wurden im Rahmen dieser Arbeit auch Lösungen für klinische Fragestellungen wie etwa den Nachweis von Methylphenidat im Plasma und Gehirn von Ratten oder der Dried Blood Spot Analytik entwickelt. Bei beiden Methoden wurde jeweils nur eine einfache Flüssig-Flüssig-Extraktion zur Probenvorbereitung angewendet und sie ließen sich sehr gut auf Realproben übertragen.
Methylphenidat konnte im Plasma im Konzentrationsbereich von 0,1-40 ng/mL und im Hirnhomogenat im Konzentrationsbereich von 0,4-40 ng/mL quantifiziert werden, was gut im Konzentrationsbereich der Realproben von mit Methylphenidat gefütterten Ratten lag. Dazu standen das Plasma und die Gehirne von fünf Ratten zur Verfügung. Es wurde eine lineare Korrelation zwischen der MPH-Konzentration im Gehirnhomogenat und im Plasma gefunden, was basierend auf den bis dato bekannten Literaturergebnissen ein zu erwartendes Ergebnis war, aber zukünftig mit einer größeren Anzahl von Versuchstieren verifiziert werden sollte. Während der Methodenentwicklung war auch bei diesem Projekt die Auswahl der MALDI-Matrix ausschlaggebend für den Erfolg der Messungen. Im MALDI-Massenspektrum interferierte das Signal des Natriumaddukts von CHCA mit dem Signal von MPH. Für dieses Problem kamen zwei mögliche Lösungen in Betracht. Erstens die Quantifizierung mit ClCCA als MALDI-Matrix, da hier keine Interferenzen auftraten. In ersten Vorversuchen konnte MPH so in einem Konzentrationsbereich von 1-48 ng/mL mit einer exzellenten Linearität von R2=0,9992 quantifiziert werden. Eine zweite mögliche Problemlösung war die Verwendung von Tandem-Massenspektrometrie. Hierzu wurden Fragmentionen-Massenspektren der überlagerten Signale aufgenommen. MPH und der verwendete interne Standard MPH-d9 zeigten dabei spezifische Fragmentionensignale, über die quantifiziert wurde. Da die Sensitivität um den Faktor 100 im Vergleich zu MS-Spektren von CHCA und ClCCA gesteigert werden konnte, wurde die weitere Methodenentwicklung basierend auf der Tandem-Massenspektrometrie mit der MALDI-Matrix CHCA durchgeführt. Überdies sind MS/MS-Versuche unter Verwendung von ClCCA als MALDI-Matrix für kleine Moleküle sehr erfolgsversprechend und sollten in weiteren Forschungsarbeiten durchgeführt werden.
Die Dried Blood Spot Technik als alternative Probenvorbereitung bietet eine Reihe von Vorteilen, wie etwa den einer einfacheren Lagerung und eines einfacheren Transports einer großen Menge von Proben. Darüber hinaus werden nur wenige Mikroliter Blut verwendet, was vorteilhaft ist bei z B. klinischen Studien oder dem Therapeutic Drug Monitoring. Diese Art der Probennahme ist somit eine perfekte Ergänzung für weitere quantitative Analysen von Methylphenidat in Rattenblut. Den Ratten würden nur wenige Mikroliter Blut entnommen werden, was ihr Überleben sichert und der Transport der Proben auf dem Postweg wäre wesentlich einfacher. Um eine allgemein verwendbare DBS-MALDI-MS-Methode zu entwickeln, wurden neben Methylphenidat auch bekannte Analyten aus dem Bereich des Dopings sowie Lamotrigin, Coffein und Theophyllin als Beispiele für das Therapeutic Drug Monitoring verwendet. Es wurden verschiedene Lösungsmittel zur Extraktion eingesetzt, wobei sich eine Kombination aus Methyl-tert-Butylether und Ethanol, sowie Aceton als am besten geeignet erwies. Einige Analyten wie Coffein, Theophyllin und Lamotrigin wurden bis zu einer Konzentration von 0,5 μg/mL quantifiziert. Diese Bestimmungsgrenze ist bei Analyten aus dem Bereich des Dopings wie z.B. Salbutamol, Methylphenidat oder Clenbuterol, deren therapeutisch wirksame Plasmakonzentration im Bereich von wenigen Nanogramm pro Milliliter Blut liegt, um den Faktor 15-500 zu hoch. Diese Analyten waren bis zu einer Konzentration von 5 μg/mL im Blut mittels MALDI-MS problemlos nachweisbar. Um die Sensitivität zu erhöhen, ist es allerdings sinnvoll, die Extraktion zukünftig für die einzelnen Analyten zu optimieren, sie mittels Festphasenextraktion oder LC anzureichern und MS/MS-Spektren aufzunehmen. Für die Analyten Coffein, Theophyllin und Lamotrigin, deren therapeutisch wirksame Plasmakonzentration im ein- bis zweistelligen Mikrogramm-pro-Milliliter Bereich liegt, eignete sich die entwickelte Methode sehr gut. Es wurde eine Methodenvalidierung durchgeführt, wobei die validierten Parameter den Vorgaben der FDA entsprachen.
Da die Auswahl der MALDI-Matrix bei den verschiedenen Methodenentwicklungen jeweils ein kritischer Faktor war, wurden abschließend eine Auswahl von Analyten mit einer Molekülmasse bis ca. 600 Da mit verschiedenen MALDI-Matrizes präpariert. Ein Großteil der Analyten wurde am sensitivsten mit ClCCA nachgewiesen. Im Rahmen dieser Versuche wurde auch erstmals ein Strukturanalogon von ClCCA, und zwar ClCCA-Tetrazol, als alternative MALDI-Matrix eingesetzt, bei welchem die Carboxylgruppe durch einen Tetrazolring ausgetauscht wurde. Diese zeigte eine sehr homogene Kristallisation und für einige Analyten eine bis zu Faktor 3 höhere Signalintensität im Vergleich zu ClCCA. Außerdem war auffällig, dass einige Analyten unter bestimmten Präparationsbedingungen wie z B. der Graphite Supported Preparation sensitiver mittels MALDI-MS nachweisbar waren. Bei anderen Analyten verschlechterten sich die Analysenergebnisse. Graphit verändert stark die Kristallisation der MALDI-Matrix und es wird vermutet, dass sich dies auf den Einbau der Analyten in die Matrixkristalle auswirkt. Es konnte bislang aber noch nicht abschließend geklärt werden, wie genau die Präparation der Proben Einfluss auf den Einbau der Analyten in die Matrix nimmt. Eine Untersuchung dieser Phänomene sollte daher Gegenstand weiterer Forschungsprojekte sein.
Zusammenfassend stellt die MALDI-Massenspektrometrie eine schnelle und robuste Methode zur Quantifizierung einer Vielzahl kleiner Moleküle in komplexen biologischen Matrizes dar.
Top-down and bottom-up approaches are the general methods used to analyse proteomic samples today, however, the bottom-up approach has been dominant in the last decade. Establishing a bottom-up method involves not only the choice of adequate instruments and the optimisation of the experimental parameters, but also choosing the right experimental conditions and sample preparation steps. LC-ESI MS/MS has widely been used in this field due to its advanced automation. The primary objective of the present study was to establish a sensitive high-throughput nLC-MALDI MS/MS method for the identification and characterisation of proteins in biological samples. The method establishment included optimisation and validation of parameters such as the capillaries in the HPLC systems, gradient slopes, column temperature, spotting frequencies or the MS and MS/MS acquisition methods. The optimisation was performed using two HPLC-systems (Agilent 1100 series and Proxeon Easy nLC system), three spotters and the 4800 MALDI-TOF/TOF analyzer. Furthermore, samples preparation protocols were modified to fit to the established nLCMALDI- TOF/TOF-platform. The potentials of this method was demonstrated by the successful analysis of complex protein samples isolated from lipid particles, pre-adipocytes/adipocytes tissues, membrane proteins and proteins pulled-down from protein-proteins interaction studies. Despite the small amount of proteins in the lipid particles or oil bodies, and the challenges encountered in studying such proteins, 41(6 novel + 14 mammal specific + 21 visceral specific) proteins were added to the already existing proteins of the secretome of human subcutaneous (pre)adipocytes and 6 novel proteins localised in the yeast lipid particles. Protein-protein interaction studies present another area of application. Here the analytical challenges are mostly due to the loss of binding partner upon sample clean-up and to differentiate from non-specific background. Novel interaction partners for AF4•MLL and AF4 protein complex were identified. Furthermore, a novel sample protocol for the analysis of membrane proteins, based on the less specific protease, elastase, was established. Compared to trypsin, a higher sequence coverage and higher coverage of the transmembrane domains were achieved. The use of this enzyme in proteomics has been limited because of its non specific cleavage. However, from the results obtained in these studies, elastase was found to cleave preferentially at the C-terminal site of the amino acids AVLIST. The advantage of the established protocol over conventional protocols is that the same enzyme can be used for shaving of the soluble dormains of intact proteins in membranes and the digestion of the hydrophobic domain after solubilisation. Furthermore, the solvents used are compatible with the nLC-MALDI method setup. In addition, it was also shown that for less specific enzymes, a higher mass accuracy is required to reduce the rate of false positive identifications, since current search engines are not perfectly adapted for these types of enzymes. A brief statistical analysis of the MS/MS data obtained from the LC-MALDI TOF/TOF system showed that for less specific enzymes, under high-energy collision conditions, approximately 43 % of the fragment ions could not be matched to the known y- b type ions and their resultant internal fragments. This limitation greatly influenced the search results. However, this limitation can be overcome by modifying the N-terminal amino acids with basic moieties such as TMT. The use of elastase as a digestion enzyme in proteomic workflow further increased the complexity of the sample. Therefore, orthogonal multidimensional separation was necessary. Offgel-IEF was used as the separation technique for the first dimension. Here peptides are separated according to the pI. However, the acquired samples could not be loaded to the nLC due to the high viscosity of the concentrated samples when using the standard protocol. In order to achieve compatibility of the Offgel-IEF to the nLC-MALDI-TOF/TOF-platform, the separation protocol of the Offgel-IEF was modified by omitting the glycerol, which was the cause of the viscous solution. The novel glycerol free protocol is advantageous over the conventional method because the samples could directly be picked-up and loaded onto the pre-column without resulting in an increase in back pressure or a subsequent pre-column clogging. The glycerol free protocol was then assessed using purple membrane and membrane fraction of C. glutamicum. The results obtained were comparable to those applied in published reports. Therefore, the absence of glycerol did not affect the separation efficiency of the Offgel-IEF. In addition the applicability of elastase and the glycerol free Offgel-IEF for quantitation of membrane proteins was assessed. Most of the unique peptides identified were in the acidic region and 85 % were focused only into one fraction and approximately 95 % in only two fractions. These results are in accordance with previously published results (Lengqvist et al., 2007). When compared with theoretical digests of the proteins identified in this study, it can be concluded that basic moiety (TMT) on the peptide backbone, did not affect the separation efficiency of the Offgel-IEF. In an applied study, changes in the protein content of yeast strain grown in two different media were relatively quantified. For example, prominent proteins, such as the hexose tranporter proteins responsible for transporting glucose accross the membrane, were successfully quantified. Last but not least, the nLC-MALDI-TOF/TOF platform also served as a basis for the development of a high-throughput method for the identification of protein phosphorylation. The establishment of such a method using MALDI has been challenging due to the lack of sensitive matrices, such as CHCA for non-modified peptides, which exhibit a homogenous crystallisation and thus yield stable signal intensity over a long period of time in an automated setup. The first step of this method was the establishment of a matrix/matrix mixture with better crystal morphology and higher analyte signal intensity than the matrix of choice, i.e. DHB. From MS and MS/MS measurements of standard phosphopeptides, a combination of FCCA and CHAC in a 3:1 ratio and 3 mM NH4H2PO4 facilitated high analyte signal intensities and good fragmentation behaviour. Combining a custom-packed biphasic column for the enrichment of phosphopeptides, the applicability of the matrix mixture was assessed in anautomated phosphopeptide analysis using standard phosphopeptides spiked to a 20-fold excess BSA digest. These analyses showed that this method is reproducibile and both flow throughs can be analysed. Applying the method to the analysis of 2 standard phosphoproteins, alpha/beta-casein, and a leukemia related protein, ENL, 13 phosphopeptides from both alpha/beta-Casein and 13 phosphopeptides with 6 phosphorylation sites from the ENL were identified. As a general conclusion, it can be stated that the nLC-MALDI-TOF/TOF method established here in various modifications for different analytical purposes is a robust platform for proteomic analyses.
Untersuchung hochmolekularer Proteinkomplexe in menschlichen Leukämien mittels Proteomics-Werkzeugen
(2009)
Funktionelle Multiproteinkomplexe stellen im Sinne von Proteomics das kleinste isolierbare Proteom dar. Die Untersuchung von Proteinkomplexen gibt uns die Möglichkeit, Funktionen innerhalb der Zelle oder des Zellkompartiments genauer zu verstehen. Erst durch das Verständnis der einzelnen kleinen Zusammenspiele innerhalb einer Zelle, können wir die Auswirkungen auf ein betreffendes Organ und damit auf den Körper betrachten. Wir erhalten dadurch auch Informationen über die Funktion von spezifischen Genen und können so Erklärungsansätze für Gendefekte finden und über mögliche Therapieansätze nachdenken. Neben den Hefe-Zwei-Hybrid-Analysen und dem Nachweis von Protein-Interaktionen mittels Immunopräzipitationsexperimenten stellt die Massenspektrometrie seit den 90er Jahren ein essentielles Werkzeug der Proteom-Forschung dar. Sie entwickelte sich zu einem etablierten Verfahren für die Charakterisierung von Biomolekülen und ermöglicht die Identifizierung unbekannter Proteine eines Komplexes. Das MLL-Gen auf Chromosom 11 Bande q23 ist in zahlreiche, reziproke chromosomale Translokationen verwickelt, die mit der Entstehung von akuten Leukämien assoziiert sind. Chromosomale Translokationen des MLL-Gens werden aufgrund ihrer sehr schlechten Prognose und Therapierbarkeit als Hochrisiko-Leukämien eingestuft. Bis heute konnten 64 Translokations-Partnergene identifiziert werden, wobei das AF4-Gen mit 42% bei allen untersuchten Leukämien und mit ca. 66% bei ALL (akute lymphatische Leukämie) den größten Prozentsatz ausmacht. Bei der Translokation t(4;11) sind das MLL-Gen auf Chromosom 11 und das AF4-Gen auf Chromosom 4 beteiligt. Akute Leukämien mit einer t(4;11)-Translokation treten häufig bei Säuglingen und Kleinkindern auf und betreffen vorwiegend den lymphatischen Zweig des blutbildenden Systems. Durch die Translokation entstehen zwei neue Derivatchromosomen – Derivat 11 (MLL•AF4, der11) und Derivat 4 (AF4•MLL, der4). Beide Fusionsgene verfügen über einen intakten Leserahmen und führen zur Expression der zwei Fusionsproteine MLL•AF4 (der11) und AF4•MLL (der4). Der pathomolekulare Mechanismus der t(4;11)-vermittelten ALL ist bis heute noch nicht hinreichend geklärt. Funktionen des der11-Fusionsproteins werden zwar schon intensiv erforscht, aber es gibt noch keine Erkenntnisse über die Funktion des der4-Fusionsproteins. Ähnlich sah die Situation zu Beginn dieser Arbeit für das AF4-Protein aus. Während schon einige Daten zur Funktion des MLL-Multiproteinkomplexes vorlagen, gab es nur wenige Informationen über die Funktion von AF4. Im Zuge dieser Arbeit wurden der AF4- und der der4-Multiproteinkomplex mittels affinitätschromatographischer Methoden aus transient transfizierten 293T-Zellen erfolgreich isoliert. Eine Größenbestimmung der Komplexe über eine Größenausschlusschromatographiesäule ergab für beide Komplexe eine Größe von ca. 2 MDa. Die Charakterisierung der beteiligten Interaktionspartner erfolgte mittels nLC-MALDI-MS/MS, Western Blot Analyse und Immunopräzipitation. Es konnte gezeigt werden, dass AF4 zusammen mit den Proteinen ENL/AF9, CDK9, CCNT1, AF10, DOT1L und der RNA-Polymerase II in einem Komplex vorliegt. Bereits 2007 konnte dieser Komplex in einem Mausmodell isoliert werden. Damit fungiert der AF4-Komplex auch in humanen Zellen als Stimulator der RNA-Polymerase-II-abhängigen transkriptionellen Elongation und vermittelt eine DOT1L-abhängige H3K79-Methylierung, die einen aktiven Transkriptionsstatus aufrechterhält. Zusätzlich konnten 6 neue Interaktionspartner identifiziert werden (AF5q31, BDR4, DDX6, HEXIM1, NFkB1/RELA und NPM1). Die Anwesenheit von BRD4 und HEXIM1 lässt vermuten, dass der AF4-Komplex in einem aktiven und einem inaktiven Zustand vorliegen kann. Außerdem wird der AF4-Komplex möglicherweise über den NFkB-Signalweg reguliert bzw. durch die Anwesenheit von NFkB1 an dessen Zielgene rekrutiert. Die Untersuchung des der4-Komplexes zeigte, dass er sich aus Mitgliedern der beiden Wildtyp-Proteinkomplexe zusammensetzt. So wurden die Proteine P-TEFb, HEXIM1, NFkB1, NPM1, DDX6 und das AF4 selbst aus dem AF4-Komplex sowie ASH2L, RBBP5, WDR5, DPY-30, CBP, HCF-1 und HCF-2 aus dem MLL-Komplex identifiziert. Der der4-Komplex weist somit partielle Eigenschaften des AF4- und MLL-Wildtyp-Proteins auf. Diese Eigenschaften sind ausreichend für eine kompetitive Situation zwischen dem der4-Komplex und den beiden AF4- und MLL-Wildtyp-Komplexen. Die Gleichgewichte dieser Wildtyp-Komplexe werden vermutlich gestört. Für beide Komplexe wurde mit Hilfe eines in vitro Histon-Methyltransferase-Assays eine Histon-Methyltransferase-Aktivität nachgewiesen. Für den AF4-Komplex muss zusätzlich eine bisher noch unbekannte Methyltransferase-Aktivität angenommen werden, da eine Methylierung des Histons H3 in den ersten 46 Aminosäuren gezeigt werden konnte, die sich nicht auf die Methyltransferase-Aktivität des DOT1L-Proteins im AF4-Komplex zurückführen lässt. Die H3K4-Methyltransferase-Aktivität des der4-Komplexes wird auf die Anwesenheit des SET-Domänen-Komplexes (ASH2L, WDR5, RBBP5 und DPY-30) zurückgeführt. Im Zusammenhang mit dem AF4-Protein wurde auch der ENL-Komplex untersucht. Mittels Western Blot konnten die Interaktionspartner AF4, CDK9, CCNT1, RNA-Polymerase II, NFkB1 und RING1 identifiziert werden. Damit ist auch das ENL mit dem globalen positiven transkriptionellen Elongationsfaktor P-TEFb assoziiert und beeinflusst die RNA-Polymerase-II-abhängige transkriptionelle Elongation.
Als Teil der Atmungskette des hyperthermophilen Bakteriums Aquifex aeolicus besteht die NADH:Ubichinon-Oxidoreduktase aus 13 Untereinheiten, die durch 24 unterschiedliche Gene codiert werden. Im Rahmen dieser Arbeit wurde für den massenspektrometrischen Nachweis dieser Untereinheiten nach der Aufreinigung des Komplexes eine SDS-PAGE durchgeführt, an die sich eine tryptische Proteolyse und eine Messung per MALDI MS und MS/MS anschlossen. Mit dieser analytischen Strategie war es möglich, jede nicht-homologe Untereinheit nachzuweisen und 20 von 24 genombasierten Isoformen eindeutig zu identifizieren. Selbst kleine bzw. sehr hydrophobe Untereinheiten mit vielen Transmembranhelices konnten mit Hilfe dieser Methode analysiert werden. Die hohe Anzahl an präsenten, unterschiedlichen Isoformen und die vorherrschenden Verunreinigungen durch Fremdproteine (z.B. ATP-Synthase) könnten Indizien dafür sein, dass bis jetzt keine hinreichend stabile und reproduzierbare Enzympräparation gelungen ist, um eine Kristallstrukturanalyse durchzuführen. Im Allgemeinen kann der Ablauf eines solchen Proteomics-Experiments in drei Teile gegliedert werden: die Auftrennung eines Protein- oder Peptidgemischs zur Verringerung der Probenkomplexität, die Identifikation des Proteins per Massenspektrometrie und die damit verbundene bioinformatische Datenanalyse. Neben chromatographischen Methoden ist die Elektrophorese in Polyacrylamidgelen immer noch das am häufigsten angewandte Trennverfahren im Proteomics-Bereich. Vor der MS-Messung werden die aufgetrennten Proteine in der Regel direkt in der Gelmatrix verdaut. Die Qualität der Ergebnisse wird stark durch Proteinmenge und die auftretenden Probenverluste beeinflusst. Diese werden beispielsweise durch eine unzureichende Peptidextraktion aus dem Gel hervorgerufen. Im Rahmen dieser Dissertation wurde ein neues Gelsystem entwickelt, dass vor allem für die Proteolyseeffizienz, die Peptidextraktion und somit auch für die anschließende massenspektrometrische Messung von Vorteil ist. Das Monomer Acrylamid wird hierzu mit den beiden Quervernetzern N,N-Methylenbisacrylamid (MBA) und Ethylenglykoldiacrylat (EDA) polymerisiert. Es entsteht ein Gel, dessen Poren durch die basische Hydrolyse der Esterbindungen des EDAs vergrößert werden können, ohne die dreidimensionale Grundstruktur des Gels zu zerstören.   Die gemischten Gele mit MBA und EDA als Crosslinkern sind sowohl für Tris-Glycin- als auch Tris-Tricin-Puffersysteme einsetzbar. Die Evaluierung der Daten erfolgte meist gegen ein Standardgel mit T= 14% und C= 2,6%. Durch eine experimentell ermittelte Anpassung der Mischgele auf T+10% und C+45% mit einem MBA/EDA-Verhältnis von 0,5 verhalten sich die beiden Gelsysteme empirisch gleich und zeigen eine übereinstimmende elektrophoretische Trennung und Auflösung. Es gibt keine wesentlichen Nachteile in Bezug auf die Handhabung, die elektrophoretische Trennung und die anschließenden Analysen und Techniken, solange diese in sauren bis leicht basischen pH-Bereichen durchgeführt werden. So wurde das gemischte Gelsystem sowohl bei einer 2D IEF/SDS-PAGE als auch bei einem Western Blot-Experiment angewendet und für vollständig kompatibel befunden. Die gemessenen MS-Daten profitieren im Fall von Trypsin und Elastase erheblich von der besseren Zugänglichkeit des Enzyms zum Substratprotein und der verbesserten Peptidextraktion. Die Gelaufweitung führt zu signifikant besseren Ergebnissen, die größtenteils auf höhere S/N-Werte zurückzuführen sind. Die Signalintensitäten der Peptide sind um den Faktor 5 besser als die des Referenzgels. Der Nachweis von je 1 pmol der Proteine BSA, Serotransferrin und Alkoholdehydrogenase profitiert stark von den zusätzlich erhaltenen Daten, da die Zunahme an identifizierten Peptiden bei der PMF-Suche im Bereich von 40 bis 80% liegt. Auch bei geringen Proteinmengen wie 250 bzw. 50 fmol BSA ist die Anzahl der zugeordneten Signale um den Faktor 2-3 besser. Der in-Gel Verdau von 1 pmol Bacteriorhodopsin mit Elastase zeigt ebenfalls einen Anstieg der Peptidsignale um 60% im Vergleich zum Referenzgel. Da die Proteine im Gel alle mit kolloidalem Coomassie Brilliant Blue angefärbt wurden, kann davon ausgegangen werden, dass sich die guten MS-Ergebnisse auf jede mit diesem Farbstoff visualisierte Probe übertragen lassen. Für den Fluoreszenzfarbstoff RuPBS trifft dies ebenso zu, insgesamt wurden aber weniger Peptide als bei kolloidaler Coomassie Brilliant Blue-Färbung detektiert. Dementsprechend handelt es sich bei Acrylamidgelen mit MBA/EDA-Vernetzung um ein vielversprechendes alternatives Gelsystem, dass auf eine Vielzahl anderer Methoden angewendet werden kann.
Die Proteomforschung wurde die letzten beiden Dekaden maßgeblich durch die Massenspektrometrie geprägt und vorangetrieben. Ohne die Ionisationstechniken MALDI und ESI wäre die Analyse von Peptiden und Proteinen nicht in dem Maße möglich. Durch das Zusammenspiel zwischen Probenvorbereitung und effektiven Trennmethoden mit hochauflösenden Massenspektrometern und Auswertungssoftware können heute problemlos komplexe Proteinmischungen oder ganze Proteome untersucht werden.
Um Proteine in Peptide zu schneiden, wird in den allermeisten Fällen die Protease Trypsin verwendet, deren Eigenschaften in vielerlei Hinsicht die bestmögliche Lösung für die nachfolgende Analyse mit Massenspektrometern bieten. Allerdings stößt die Anwendbarkeit dieses Enzyms bei der Analyse von einigen Proteinen oder Proteinklassen wie Membranproteinen an ihre Grenzen, da nur sehr wenige potentielle Schnittstellen vorhanden sind. In solchen Fällen wurden eine Reihe von weniger spezifischen Enzymen wie Chymotrypsin, Proteinase K oder Elastase in den vergangenen Jahren genutzt, die Proteine auch in für Trypsin weniger gut zugänglichen Bereichen wie Transmembranhelices, in massenspektrometrisch analysierbare Peptide spalten können.
Allerdings stellen die wenig spezifischen Enzyme und die von ihnen generierten Peptide die Massenspektrometrie vor neue Herausforderungen. Für eine Identifizierung benötigen die Peptide eine sehr hohe Massengenauigkeit, daneben sind insbesondere bei der Verwendung von MALDI-Massenspektrometern neutrale und sehr saure Peptide schwerer ionisierbar und analysierbar als basische.
Genügte es bis vor einigen Jahren, nur die Identität einzelner Proteine in komplexen Proben zu bestimmen, hat sich die Fragestellung mittlerweile einem Wandel unterzogen. Heute ist man daran interessiert, wie viel eines bestimmten Proteins vorliegt, besonders im Vergleich mit anderen, unterschiedlich behandelten Proben ist die Regulation von Proteinen von Interesse. Zum Quantifizieren stehen viele unterschiedliche Methoden zur Verfügung. Eine solche stellen die isobaren Derivatisierungsreagenzien TMT und iTRAQ dar, mit denen unterschiedliche Proben nach Peptidfragmentierung quantifiziert werden können.
Fast alle Arbeiten zur Quantifizierung in der Vergangenheit benutzten Trypsin als Protease.
Im Zuge dieser Arbeit sollten die Vorteile, die durch die Verwendung von Elastase bei der Identifizierung von Membranproteinen bereits gezeigt werden konnten, auf die Quantifizierung mit TMT erweitert werden.Wurde in der Vergangenheit noch in manchen Publikationen davon abgeraten, Elastase zu verwenden,weil die Nutzbarkeit der dabei gebildeten komplexen Peptidmischungen in Frage gestellt wurde, konnte in dieser Arbeit gezeigt werden, dass Elastase wie auch Trypsin sich eignen, als Enzym für Quantifizierungsexperimente verwendet zu werden. Dies wurde an Modellproteinen evaluiert und dann auf komplexe Membranproben von Hefezellen erweitert.
Bei Vorexperimenten zur Derivatisierung mit TMT wurde desweiteren festgestellt, dass Peptidklassen, die zuvor nur mit ESI als Ionisationsmethode identifiziert werden konnten, durch die Derivatisierung nun auch mit MALDI zugänglich waren. Die dadurch analysierten kleinen, hydrophoben und sehr sauren Peptide lieferten bei der Kombination mit der underivatisierten Probe einen deutlichen Zugewinn in der Sequenzabdeckung der identifizierten Proteine.
Ein weiterer Teil der Arbeit beschäftigt sich mit der nachträglichen Korrektur von gemessenen Peptidmassen über selbst geschriebene Softwarelösungen für verschiedene Massenspektrometer. Es wurde das Ziel verfolgt, eine möglichst hohe Massengenauigkeit und damit hohe Anzahl an Identifizierungen von Proteinen nach Verdau mit wenig spezifischen Proteasen zu erreichen. Weitere Computerprogramme wurden mit dem Ziel geschrieben, den Arbeitsablauf zu erleichtern und zu verbessern.
Für die früher schon beschriebene Kombination zweier Massenspektrometer mit hoher Massengenauigkeit und Auflösung auf der einen Seite und effizienter Peptidfragmentierung auf der anderen Seite konnte durch Veränderung der Instrumentierung und Software nun eine Automatisierbarkeit geschaffen werden, die es ermöglicht, die Methode standardmäßig bei Routineanalysen zu verwenden.
So ergeben sich viele neue Möglichkeiten neben den oft gewählten Standardprotokollen mit der Analyse tryptischer Verdauansätze mittels LC-ESI-MS/MS, die häufig nur der Einfachheit halber und ohne Anpassung an die eigene Zielsetzung gewählt werden.
Die Arbeit zeigt aber auch auf, dass die Verwendung weniger spezifischer Enzyme sowohl eine Optimierung des Arbeitsablaufs als auch eine Datenauswertung benötigt, die die Besonderheiten der Proteasen berücksichtigt. Wenn dies gewährleistet wird, kann vor allem mit dem Zugewinn durch die Derivatisierung mit TMT eine wertvolle Alternative zu Trypsin genutzt werden.
Biopharmazeutika sind heutzutage ein wichtiger Bestandteil des Arzneimittelmarktes. Ihr komplexer Aufbau und ihre Mikroheterogenität erfordern eine genaue strukturelle Charakterisierung auf verschiedenen Ebenen der Moleküle, wobei die Anwendung neuer Methoden von den entsprechenden Richtlinien durchaus erwünscht ist. Die Massenspektrometrie als Analysemethode hat sich in diesem Gebiet bereits fest etabliert. Verschiedenste massenspektrometrische Untersuchungen können an den intakten Biopharmazeutika sowie an größeren und kleineren Bruchstücken derselben durchgeführt werden. Trotzdem wird meist auf wenige, lange etablierte Protokolle zurückgegriffen, die häufig mit langwieriger Probenvorbereitung verbunden sind. Bei der Analyse der Glykosylierung wird immer noch die chromatographische Trennung mit anschließender Detektion durch UV- oder Fluoreszenzmessung bevorzugt.
In dieser Arbeit sollten die Möglichkeiten der Massenspektrometrie bei der Analyse von Biopharmazeutika genauer untersucht werden. Dazu gehört auch, den hohen Informationsgehalt der üblichen chromatographischen Auftrennung von Peptiden aus einem proteolytischen Verdau vollständig zu nutzen. Es wurde gezeigt, dass die manuelle Auswertung der Analyse zusätzliche Ergebnisse bringt, und dass gleichzeitig eine Analyse von posttranslationalen und prozessbedingten Modifikationen möglich ist. Zudem wurde der Verdau mit der Protease Trypsin auf das jeweilige Biopharmazeutikum und auf das Ziel der Analyse optimiert. Da mit Trypsin eine vollständige Sequenzabdeckung nicht erreichbar war, wurden zusätzlich verschiedene weniger spezifische Proteasen angewendet. Alle untersuchten weniger spezifischen Proteasen (Elastase, Chymotrypsin und Thermolysin) waren für eine solche Analyse gut geeignet. Die Komplementarität von MALDI- und ESI-MS-Analysen konnte durch ihre Kombination optimal ausgeschöpft werden. Zudem wurden weitere Methoden zur Erhöhung der Sequenzabdeckung wie die Derivatisierung der Peptide mit TMTzero vorgestellt.
Für die Analyse intakter Biopharmazeutika wurden neben der Größenausschlusschromatograph und gelelektrophoretischen Trennungen sowohl MALDI- als auch ESI-MS-Analysen verwendet. Die Trennung großer Proteinmoleküle in kleinere Untereinheiten erleichterte dabei die massenspektrometrische Analyse maßgeblich. Die Fragmentierung der Biopharmazeutika mittels MALDI-ISD war für die Bestimmung der Protein-N- und C-Termini sehr gut geeignet.
Die Analyse der Glykosylierung wurde an den freien N-Glykanen aus einem PNGaseF-Verdau sowie an Glykopeptiden aus einem Verdau mit Pronase durchgeführt. Die freien N-Glykane konnten zudem für die MALDI-MS-Analyse mit der MALDI-Matrix 3-Aminochinolin direkt auf dem Probenteller derivatisiert werden. Die Derivatisierung und Vermessung der N-Glykane wurde zunächst an verschiedenen Standardoligosacchariden, Humanmilcholigosacchariden und N-Glykanen aus Standardglykoproteinen optimiert. Durch die Fragmentierung der N-Glykane konnten diese sequenziert und isomere Strukturen unterschieden werden.
Bei einem Pronaseverdau wurden Proteine so weit verdaut, dass nur noch einzelne Aminosäuren bzw. Di- oder Tripeptide übrig blieben. Lediglich die Glykosylierungsstellen waren durch die voluminösen Glykanstrukturen vor dem Verdau geschützt und behielten eine kurze Peptidsequenz, die für eine Identifizierung der Glykosylierungsstelle ausreichend war. So konnten die N- und O-Glykopeptide direkt ohne Aufreinigung mittels MALDI-MS aus den Verdauansätzen analysiert werden, ohne dass nicht glykosylierte Peptide störten. Das Verdauprotokoll wurde zunächst an mehreren Standard-N- und -O-Glykoproteinen optimiert und anschließend auf die untersuchten Biopharmazeutika angewendet. N- und O-Glykopeptide konnten sogar nebeneinander analysiert werden. Die hohe Massengenauigkeit des verwendeten MALDI LTQ-Orbitrap Massenspektrometers ließ eine eindeutige Identifizierung der Glykopeptide mit Hilfe eines dafür entwickelten Programms zu. Weiterhin konnte die Identifizierung durch die Fragmentierung der Glykopeptide unterstützt werden.
Somit konnten in dieser Arbeit verschiedene massenspektrometrische Analysen von Biopharmazeutika neu entwickelt, optimiert oder vereinfacht werden. Dabei wurden für jede Strukturebene (intaktes Molekül, größere und kleinere Fragmente) sowohl Ansätze mit MALDI-MS als auch mit ESI-MS verfolgt. Einige Methoden, die in der Proteomforschung bereits Anwendung fanden, konnten erfolgreich auf Biopharmazeutika übertragen werden. Die Arbeit zeigt, dass die Massenspektrometrie ein großes Potential in der Analyse der Biopharmazeutika besitzt, das aber bisher noch nicht vollständig ausgeschöpft wird. Durch die Wahl der richtigen Methoden und der geeigneten Instrumentierung wird eine vollständige strukturelle Charakterisierung ermöglicht.
Das Rauchen von Kokain („Crack“) hat sich in den letzten Jahren weltweit verbreitet und Crack hat eine wichtige Stellung in der Gruppe der harten Drogen eingenommen. Der inhalative Konsum unterscheidet sich von den anderen Formen der Kokain-Aufnahme durch seine schnelle und intensive Wirkung sowie durch einen sehr starken, unkontrollierten Drang zum erneuten Konsum. Schwere gesundheitliche Schäden sind die Folge sowie auch soziale Isolierung und zwischenmenschliche Konflikte. Da zur Finanzierung der Crack-Sucht häufig Straftaten begangen werden, sind diese Fälle forensisch von besonderem Interesse. Im Gegensatz zum nasalen oder intravenösen Konsum entsteht ausschließlich beim Rauchen das Pyrolyseprodukt Anhydroecgoninmethylester (AEME), welches deshalb als Marker für einen Crack-Konsum angesehen wird. Die toxikologischen Aspekte dieser Substanz sind nicht ausreichend untersucht, um dessen toxikologisches Potential abschätzen zu können. Im Rahmen der vorliegenden Arbeit sollten analytische Methoden entwickelt und der Metabolismus von AEME untersucht werden, um Daten an authentischen Proben von Kokainkonsumenten erheben zu können.