Universitätspublikationen
Refine
Year of publication
Document Type
- Article (27)
- Conference Proceeding (5)
Has Fulltext
- yes (32)
Is part of the Bibliography
- no (32)
Keywords
- DMEK (5)
- Amblyopia (3)
- Dose response (3)
- Eccentric fixation (3)
- Efficiency (3)
- Occlusion treatment (3)
- Fuchs endothelial dystrophy (2)
- Scheimpflug imaging (2)
- Visual quality (2)
- corneal edema (2)
- corneal transplantation (2)
- Arteria ophthalmica (1)
- Augenerkrankungen (1)
- Autoimmune response (1)
- Blindness (1)
- CBA (1)
- CRVO (1)
- Corneal tomography (1)
- DSAEK (1)
- Education (1)
- Endocrinology (1)
- Eye diseases (1)
- EyesiNet (1)
- Filler (1)
- Glabella (1)
- IL-6 (1)
- Kidney diseases (1)
- Lehre (1)
- MCP-1 (1)
- Mini-monovision (1)
- Netzhaut (1)
- Non-diffractive EDOF-IOL (1)
- Occlusion (1)
- Ocular tuberculosis (1)
- Ophthalmoplegia (1)
- Optical phenomena (1)
- Phlyctenule (1)
- Presbyopia (1)
- Pseudophakia (1)
- Refractive changes (1)
- Refractive lense exchange (1)
- Retina (1)
- Retinal diseases (1)
- SD-OCT (1)
- Scrofulous keratitis (1)
- Student (1)
- Type 2 diabetes (1)
- VEGF (1)
- Vitreous samples (1)
- anterior chamber depth changes (1)
- cataract surgery (1)
- corneas (1)
- deswelling (1)
- diabetic macular edema (1)
- effective lens position (1)
- fluocinolone acetonide (1)
- keratoplasty (1)
- microdosing (1)
- microkeratome (1)
- pseudoexfoliative syndrome (1)
- repeat DMEK (1)
Institute
- Medizin (32)
There is limited knowledge on the prevalence and risk factors of diabetic retinopathy (DR) in dialysis patients. We have investigated the association between diabetes mellitus and lipid-related biomarkers and retinopathy in hemodialysis patients. We reviewed 1,255 hemodialysis patients with type 2 diabetes mellitus (T2DM) who participated in the German Diabetes and Dialysis Study (4D Study). Associations between categorical clinical, biochemical variables and diabetic retinopathy were examined by logistic regression. On average, patients were 66 ± 8 years of age, 54% were male and the HbA1c was 6.7% ± 1.3%. DR, found in 71% of the patients, was significantly and positively associated with fasting glucose, HbA1c, time on dialysis, age, systolic blood pressure, body mass index and the prevalence of other microvascular diseases (e.g. neuropathy). Unexpectedly, DR was associated with high HDL cholesterol and high apolipoproteins AI and AII. Patients with coronary artery disease were less likely to have DR. DR was not associated with gender, smoking, diastolic blood pressure, VLDL cholesterol, triglycerides, and LDL cholesterol. In summary, the prevalence of DR in patients with type 2 diabetes mellitus requiring hemodialysis is higher than in patients suffering from T2DM, who do not receive hemodialysis. DR was positively related to systolic blood pressure (BP), glucometabolic control, and, paradoxically, HDL cholesterol. This data suggests that glucose and blood pressure control may delay the development of DR in patients with diabetes mellitus on dialysis.
Purpose: To evaluate the potential impact of rebubbling on the anterior segment parameters and refractive outcomes in patients with graft detachment following uneventful DMEK for Fuchs endothelial dystrophy (FED).
Methods: Retrospective institutional cohort study of comparing 34 eyes of 31 patients with rebubbling for graft detachment following Descemet membrane endothelial keratoplasty (DMEK) to 33 eyes of 28 patients with uneventful DMEK. Main outcome parameters were various corneal parameters obtained by Scheimpflug imaging, refractive outcome, corrected distance visual acuity (CDVA), and endothelial cell density (ECD).
Results: Anterior and posterior corneal astigmatism, corneal densitometry, central corneal thickness, and anterior chamber depth and volume showed no significant differences. Preoperative distribution of astigmatism axis orientations showed a high proportion of anterior corneal with-the-rule astigmatism (71%) in eyes requiring rebubbling. Mean postoperative cylinder in the rebubbling group (1.21 ± 0.85 D) was significantly higher compared to the controls (p = 0.04), while differences in spherical equivalent (SE) were insignificant (p = 0.24). Postoperative CDVA was 0.11 ± 0.11 in the control group compared to 0.21 ± 0.17 in the rebubbling group (p = 0.03). Eyes with subsequent rebubbling demonstrated a significantly higher endothelial cell loss (56% versus 37%) (p < 0.001).
Conclusion: Apart from higher cylinder values, refractive outcome and corneal parameters assessed by Scheimpflug imaging were comparable in eyes with rebubbling and controls. However, a reduced visual acuity and an increased endothelial cell loss should be taken into consideration prior to rebubbling especially in eyes with circumscribed graft detachment.
Purpose: Filler injections for aesthetic purposes are very popular, but can have far-reaching and irreversible consequences. This report describes the course of a patient with devastating complications after glabellar hyaluronic acid injection, their pathomechanism, management and outcome.
Observations: A healthy, 43-year-old woman underwent her first hyaluronic acid injection in the glabella and went blind on her left eye immediately thereafter. Massaging of the injection area and observation were performed, before she presented with swelling of the left forehead and upper lid, ptosis, complete ophthalmoplegia and blindness in our hospital. Immediate massaging of the globe and systemic therapy including acetylsalicylic acid, tinzaparin sodium and cortisone was initiated and hyaluronidase injections in the injection area were performed. In the further course, the patient developed necrotic and hemorrhagic skin and mucosal lesions, lagophthalmos, anterior and posterior segment ischemia and globe hypotonia with consecutive globe deformation. In the follow-up of 2.5 months, lid swelling, lagophthalmos and ptosis resolved and keratopathy improved but blindness, skin lesions and strabismus with reduced eye motility were still present and madarosis and early enophthalmos were detected.
Conclusions and Importance: The outcome of ophthalmic artery occlusion after hyaluronic acid filler injection is poor. Sufficient knowledge about facial anatomy, the implementation of filler injections and the management of complications is essential for the practitioner. The patient should be clarified about potential and even rare risks of these procedures.
Purpose: The use of a non-diffractive extended-depth-of-focus (EDOF) intraocular lens (IOL) with slight myopia of −0.5 D on the non-dominant eye increases the spectacle independence and has good subjective tolerance with optical phenomena comparable to those of a monofocal IOL. This case report describes the course of a myopic patient who underwent refractive lens exchange, didn't tolerate mini-monovision and received IOL exchange therefore.
Observations: A healthy, 62-year-old male with myopia of approximately −5 D underwent refractive lens exchange with a non-diffractive EDOF-IOL on both eyes with slight myopia on the non-dominant left eye (mini-monovision). The operation was performed without any complications, postoperative treatment was due to the clinic's standard procedure. Two weeks postoperative the patient presented with uncorrected distance visual acuity of 0.0 logMAR, a subjective refraction of −0.25/−0.25/142° and corrected distance visual acuity of 0.1 logMAR on the right eye. On the left eye, distance visual acuity was 0.4 logMAR with a subjective refraction of −0.5/−0.75/9° (intended mini-monovision) and corrected distance visual acuity of 0.0 logMAR. Binocular distance visual acuity was 0.0 logMAR. The patient complained about the occurrence of optical phenomena at dim light while driving a car and subjective reduced visual acuity. After an IOL exchange on the left eye with the implantation of the same type of non-diffractive EDOF-IOL aimed for emmetropia, the patient was symptom-free and reported no more subjective complaints.
Conclusions: Despite the satisfying subjective and objective visual outcome which is proven in multiple studies, the subjective perception of a mini-monovision with a non-diffractive EDOF-IOL can vary individually. A preoperative assessment of the patient's needs and tolerance of a mini-monovision is crucial for a satisfying postoperative outcome.
Purpose: To report a case of autoimmune keratitis in a patient with mycobacterium tuberculosis (MBT).
Methods: An 84-year-old male with pulmonary tuberculosis (TB) was admitted with chronic, non-healing bilateral ulcerations of the inferior peripheral cornea associated with stromal and subconjunctival nodules.
Results: Clinical examination revealed circumscribed peripheral corneal ulceration with whitish nodules in adjacent stromal and subconjunctival tissue. Microbiological cultures of the corneal tissue were negative for MBT and other microbial pathogens; however, enzyme-linked immunosorbent assay (ELISA) of blood and corneal samples showed significantly elevated levels of IgM and IgA against MBT. In addition to systemic anti-tuberculosis therapy, the patient was treated topically with Polyspectran® eye drops, Dexamethasone eye drops, and Bepanthen® ointment, for 2 weeks. Both eyes showed dramatic improvement after 2 weeks.
Conclusion: The present report demonstrates that MBT is able to initiate delayed autoimmune response within the corneal tissue during an intensive phase of anti-tuberculosis treatment.
Hintergrund: Die Ophthalmoskopie ist Bestandteil des medizinischen Curriculums, jedoch das Vermitteln der Inhalte oft unbefriedigend, da ein systematisches Lernen von Pathologien und deren Behandlungen dadurch erschwert ist, dass oftmals das passende Patientengut nicht zur Verfügung steht und dadurch gesunde Studenten einander untersuchen müssen. Aus diesem Grund haben wir eine Online-Plattform entwickelt, die in Kombination mit simulationsgestütztem Training sowohl das eigenständige als auch das angeleitete Lernen von Untersuchungsmethoden und Pathologien ermöglicht.
Ziel der Arbeit: Ziel der vorliegenden Arbeit war, ein Format für die Verbesserung der Lehre der direkten und indirekten Ophthalmoskopie im Studierendenunterricht zu evaluieren. Dabei wurden praktische Übungen an Virtual-Reality-basierten Simulatoren mit neu entwickelten und an den Lehrkatalog angepassten theoretischen Inhalten in der Online-Plattform EyesiNet verschränkt.
Material und Methoden: Die Studierenden bearbeiteten am ersten sowie am letzten Praktikumstag zufällig ausgewählte Fälle, die ihnen von den Eyesi Direct- und Eyesi Indirect-Simulatoren präsentiert wurden. Zwischen diesen beiden Einheiten konnten sie sich auf freiwilliger Basis mit den theoretischen Grundlagen typischer ophthalmologischer Krankheitsbilder im EyesiNet beschäftigen.
Ergebnisse: Eyesi Direct: Die Bewertung des Simulators ergab am ersten Praktikumstag für beide Gruppen keinen signifikant unterschiedlichen Wissensstand (p = 0,29). In der Gruppe OHNE Training (n = 54) ergab sich am letzten Praktikumstag mit p = 0,02 eine signifikante Verbesserung dieser Bewertung, jedoch mit einer geringen Effektgröße von 0,1. In der Gruppe MIT Training (n = 32) konnte mit p = 0,0004 eine hoch signifikante Verbesserung mit einer Effektgröße von 0,3 nach Rosenthal festgestellt werden. Eyesi Indirect: Die simulatorgestützte Bewertung ergab am ersten Praktikumstag keinen signifikanten Unterschied im Wissensstand der beiden Gruppen (p = 0,1). Nach dem Training schnitten zwar beide Gruppen etwas besser ab, jedoch ohne signifikanten Unterschied (OHNE Training p = 0,41/MIT Training p = 0,17).
Diskussion: Die Online-Plattform EyesiNet unterstützt beim Erlernen der wichtigsten Erkrankungsbilder. Lerninhalte werden reproduzierbar und auf für alle Lernenden standardisierte Weise zur Verfügung gestellt. Die Fertigkeiten der direkten Ophthalmoskopie sind hierbei deutlich schneller als die der indirekten Ophthalmoskopie zu erlernen.
Purpose: To compare the effective lens position (ELP), anterior chamber depth (ACD) changes, and visual outcomes in patients with and without pseudoexfoliation syndrome (PEX) after cataract surgery.
Design: Prospective, randomized, fellow-eye controlled clinical case series.
Methods: This prospective comparative case series enrolled 56 eyes of 56 consecutive patients with (n = 28) or without PEX (n = 28) and clinically significant cataract who underwent standard phacoemulsification and were implanted with single-piece acrylic posterior chamber intraocular lenses (IOLs). The primary outcome parameters were the ACD referring to the distance between the corneal anterior surface and the lens anterior surface, which is an indicator of the postoperative axial position of the IOL (the so-called ELP) and distance corrected visual acuity (DCVA).
Results: Before surgery, the ACD was 2.54 ± 0.42 mm in the PEX group and 2.53 ± 0.38 mm in the control group (p = 0.941). Postoperatively, the ACD was 4.29 ± 0.71 mm in the PEX group and 4.33 ± 0.72 mm in the normal group, respectively (p = 0.533). There was no significant difference in ACD changes between groups (PEX group: 1.75 ± 0.74 mm, control group: 1.81 ± 0.61 mm, p = 0.806) and DCVA pre- (p = 0.469) and postoperatively (PEX group: 0.11 ± 0.13 logMAR, control group: 0.09 ± 0.17 logMAR, p = 0.245) between groups.
Conclusion: Preoperative and postoperative ACD, as an indicator of ELP, between PEX eyes and healthy eyes after cataract surgery showed no significant difference. Phacoemulsification induced similar changes in eyes with PEX compared to healthy eyes.