Universitätspublikationen
Refine
Year of publication
- 2020 (6) (remove)
Language
- English (6)
Has Fulltext
- yes (6) (remove)
Is part of the Bibliography
- no (6)
Keywords
- Anti-CMV IgG (1)
- CMVepidemiology (1)
- COVID-19 (1)
- Congenital CMVinfection (1)
- Cytomegalovirus (CMV) (1)
- Human immunodeficiency virus (HIV) (1)
- SARS-CoV-2 (1)
- Seroprevalence (1)
- coronavirus (1)
- qRT-PCR detection (1)
Institute
- Medizin (6)
Background: In the pandemic, testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) by real-time polymerase chain reaction is one of the pillars on which countermeasures are based. Factors limiting the output of laboratories interfere with the effectiveness of public health measures. Conserving reagents by pooling samples in low-probability settings is proposed but may cause dilution and loss of sensitivity. Blood transfusion services had experience in performance of high throughput nucleic acid testing (NAT) analysis and can support the national health system by screening of the inhabitants for SARS-COV-2.
Methods: We evaluated a new approach of a multiple-swab method by simultaneously incubating multiple respiratory swabs in a single tube. Analytical sensitivity was constant up to a total number of 50 swabs. It was consequently applied in the testing of 50 symptomatic patients (5-sample pools) as well as 100 asymptomatic residents of a nursing home (10-sample pools).
Results: The novel method did not cause false-negative results with nonsignificantly differing cycle threshold values between single-swab and multiple-swab NAT. In two routine applications, all minipools containing positive patient samples were correctly identified.
Conclusions: The new method enables countries to increase the total number of testing significantly. The multiple-swab method is able to screen system relevant groups of employees frequently. The example in Germany shows that blood transfusion services can support general health systems with their experience in NAT and their high-throughput instruments. Screening of a huge number of inhabitants is currently the only option to prevent a second infection wave and enable exit strategies in many countries.
Background In the pandemic, testing for SARS-CoV-2 by RT-PCR in one of the pillars on which countermeasures are based. Factors limiting the output of laboratories interfere with the effectiveness of public health measures. Conserving reagents by pooling samples in low-probability settings is proposed, but may cause dilution and loss of sensitivity.
Methods We tested an alternate approach (FACT) by simultaneously incubating multiple respiratory swabs in a single tube. This protocol was evaluated by serial incubation of a respiratory swab in up to 10 tubes. The analytics validity of this concept was demonstrated in a five-sample mini pool set-up. It was consequently applied in the testing of 50 symptomatic patients (five-sample pools) as well as 100 asymptomatic residents of a nursing home (ten-sample pools).
Results Serial incubation of a respiratory swab in up to 10 tubes did not lead to a significant decline in viral concentration. The novel FACT-protocol did not cause a false negative result in a five-sample mini-pool setup, with non-significantly differing Ct values between single sample and mini-pool NAT. In two routine applications, all mini pools containing positive patient samples were correctly identified.
Conclusions Our proposed FACT-protocol did not cause a significant loss in analytic or diagnostic sensitivity compared to single sample testing in multiple setups. It reduced the amount of reagents needed by up to 40%, and also reduced hands-on time. This method could enhance testing efficiency, especially in groups with a low pretest-probability, such as systemically relevant professional groups.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can spread from symptomatic patients with COVID-19, but also from asymptomatic individuals. Therefore, robust surveillance and timely interventions are essential for the control of virus spread within the community. In this regard the frequency of testing and speed of reporting, but not the test sensitivity alone, play a crucial role. In order to reduce the costs and meet the expanding demands in real-time RT-PCR (rRT-PCR) testing for SARS-CoV-2, complementary assays, such as rapid antigen tests, have been developed. Rigorous analysis under varying conditions is required to assess the clinical performance of these tests and to ensure reproducible results. We evaluated the sensitivity and specificity of a recently licensed rapid antigen test using 137 clinical samples in two institutions. Test sensitivity was between 88.2-89.6% when applied to samples with viral loads typically seen in infectious patients. Of 32 rRT-PCR positive samples, 19 demonstrated infectivity in cell culture, and 84% of these samples were reactive with the antigen test. Seven full-genome sequenced SARS-CoV-2 isolates and SARS-CoV-1 were detected with this antigen test, with no cross-reactivity against other common respiratory viruses. Numerous antigen tests are available for SARS-CoV-2 testing and their performance to detect infectious individuals may vary. Head-to-head comparison along with cell culture testing for infectivity may prove useful to identify better performing antigen tests. The antigen test analyzed in this study is easy-to-use, inexpensive, and scalable. It can be helpful in monitoring infection trends and thus has potential to reduce transmission.
This case series assessed a commercial airline flight from Tel Aviv, Israel, to Frankfurt, Germany, that occurred on March 9th, 2020. Among 102 passengers on a Boeing 737-900 aircraft were 24 members of a tourist group. Starting 7 days earlier, the group had contact with a hotel manager who later received a diagnosis of coronavirus disease 2019 (COVID-19). No member of the group had received a diagnosis of COVID-19 before the flight, and no measures to prevent transmission (eg, wearing of masks) had been applied. The flight duration was 4 hours 40 minutes.
The novel coronavirus SARS-CoV-2 is the causative agent of the acute respiratory disease COVID-19, which has become a global concern due to its rapid spread. Meanwhile, increased demand for testing has led to a shortage of reagents and supplies and compromised the performance of diagnostic laboratories in many countries. Both the World Health Organization (WHO) and the Center for Disease Control and Prevention (CDC) recommend multi-step RT-PCR assays using multiple primer and probe pairs, which might complicate the interpretation of the test results, especially for borderline cases. In this study, we describe an alternative RT-PCR approach for the detection of SARS-CoV-2 RNA that can be used for the probe-based detection of clinical isolates in diagnostics as well as in research labs using a low-cost SYBR green method. For the evaluation, we used samples from patients with confirmed SARS-CoV-2 infections and performed RT-PCR assays along with successive dilutions of RNA standards to determine the limit of detection. We identified an M-gene binding primer and probe pair highly suitable for the quantitative detection of SARS-CoV-2 RNA for diagnostic and research purposes.
Human cytomegalovirus (CMV) is a significant cause of morbidity and mortality in patient groups at risk. We have previously shown that the anti-CMV IgG seroprevalence in an urban region of Germany has changed over the last decades. Overall, a decline from 63.7 to 57.25% had been observed between 1988–1997 and 1998–2008 (p < 0,001). Here, we continuously follow the trends to the most recent decade 2009 to 2018. In a retrospective analysis, we determined the seroprevalence of CMV IgG antibodies in our patient cohort, stratified by gender and selected groups at risk (e.g., patients with HIV infection; women of childbearing age). The overall prevalence of anti-CMV IgG non-significantly declined further from 57.25% in 1998–2008 to 56.48% in 2009–2018 (p = 0.881). Looking at gender differences, overall CMV seroprevalence in males declined to 52.82% (from 55.54% in 1998–2008; p = 0.0254), while it non-significantly increased in females to 59.80%. The high seroprevalence in patients with a known HIV infection further increased from 87.46% in 1998–2008 to 92.93% in the current period (p = 0.9999). In women of childbearing age, no significant changes over the last three decades could be observed. The CMV seroprevalence in oncological patients was determined to be 60.64%. Overall, the former significant decline of CMV seroprevalence between the decades 1988–1997 and 1998–2008 in this urban region of Germany slowed down to a non-significant decrease of 0.77% (1998–2008 vs. 2009–2018). This might be an indicator that CMV seroprevalence has reached a plateau.