Universitätspublikationen
Filtern
Dokumenttyp
Sprache
- Englisch (5) (entfernen)
Volltext vorhanden
- ja (5) (entfernen)
Gehört zur Bibliographie
- nein (5)
Schlagworte
- dental implant (5) (entfernen)
Institut
- Medizin (5)
Porous tantalum trabecular metal biomaterial has a similar structure to trabecular bone, and was recently added to titanium dental implants as a surface enhancement. The purpose of this prospective pilot study was to describe 5-year survival results and crestal bone level changes around immediately-provisionalized Trabecular Metal Dental Implants. Eligible patients were adults in need of ≥1 implants in the posterior jaw. A non-occluding single acrylic provisional crown was in place for up to 14 days before final restoration. Clinical evaluations with radiographs were conducted at each follow-up visit (1 month, 3 months, 6 months, and 1 to 5 years). The primary endpoint was implant survival, characterized using the Kaplan-Meier method. The secondary endpoint was changes in crestal bone level, evaluated using a paired t-test to compare mean crestal bone levels between the baseline, 6-month, and annual follow-up values. In total, 30 patients (37 implants) were treated. Mean patient age was 45.5 years, and 63% were female. There was one implant failure; cumulative survival at 5 years was 97.2%. After the initial bone loss of 0.40 mm in the first 6 months, there were no statistically significant changes in crestal bone level over time up to 5 years of follow-up.
Aim: To evaluate the influence of the width of keratinized tissue (KT) on the prevalence of peri-implant diseases, and soft- and hard-tissue stability.
Materials and methods: Clinical studies reporting on the prevalence of peri-implant diseases (primary outcome), plaque index (PI), modified plaque index (mPI), bleeding index (mBI), bleeding on probing (BOP), probing pocket depths (PD), mucosal recession (MR), and marginal bone loss (MBL) and/or patient-reported outcomes (PROMs; secondary outcomes) were searched. The weighted mean differences (WMD) were estimated for the assessed clinical and radiographic parameters by employing a random-effect model that considered different KT widths (i.e., <2 and ≥2 mm).
Results: Twenty-two articles describing 21 studies (15 cross-sectional, five longitudinal comparative studies, and one case series with pre–post design) with an overall high to low risk of bias were included. Peri-implant mucositis and peri-implantitis affected 20.8% to 42% and at 10.5% to 44% of the implants with reduced or absent KT (i.e., <2 mm or 0 mm). The corresponding values at the implant sites with KT width of ≥2 mm or >0 mm were 20.5% to 53% and 5.1% to 8%, respectively. Significant differences between implants with KT < 2 mm and those with KT ≥ 2 mm were revealed for WMD for BOP, mPI, PI, MBL, and MR all favoring implants with KT ≥ 2 mm.
Conclusion: Reduced KT width is associated with an increased prevalence of peri-implantitis, plaque accumulation, soft-tissue inflammation, mucosal recession, marginal bone loss, and greater patient discomfort.
Objectives: To evaluate peri-implant tissue dimensions following nonsurgical (NS) and surgical therapy (S) employing different decontamination protocols of advanced ligature-induced peri-implantitis in dogs.
Material & Methods: Peri-implantitis defects (n = 5 dogs, n = 30 implants) were randomly and equally allocated in a split-mouth design to NS or S treatment using either an Er:YAG laser (ERL), an ultrasonic device (VUS), or plastic curettes + local application of metronidazole gel (PCM), respectively. Horizontal bone thickness (hBT) and soft tissue thickness (hMT) were measured at different reference points: (v0) at the marginal portion of the peri-implant mucosa (PM); (v1) at 50% of the distance from PM to bone crest (BC); (v2) at the BC; (v3) at the most coronal extension of the bone-to-implant contact. Vertical peri-implant tissue height was calculated from PM to BC.
Results: All of the treatment groups showed a gradual hMT increase from v0 to the v2 reference point, followed by a reduction from v2 to the v3 region. The S-VUS subgroup tended to be associated with higher hMT values at the v0 region than the NS-VUS subgroup (0.44 mm versus 0.31 mm). PM-BC distance varied from 2.22 to 2.83 mm in the NS group, and from 2.07 to 2.38 in the S group.
Conclusion: Vertical and horizontal peri-implant tissue dimensions were similar in different treatment groups.
Purpose: Bacterial biofilms are a major problem in the treatment of infected dental and orthopedic implants. The purpose of this study is to investigate the cleaning effect of an electrolytic approach (EC) compared to a powder-spray system (PSS) on titanium surfaces. Materials and Methods: The tested implants (different surfaces and alloys) were collated into six groups and treated ether with EC or PSS. After a mature biofilm was established, the implants were treated, immersed in a nutritional solution, and streaked on Columbia agar. Colony-forming units (CFUs) were counted after breeding and testing (EC), and control (PSS) groups were compared using a paired sample t-test. Results: No bacterial growth was observed in the EC groups. After thinning to 1:1,000,000, 258.1 ± 19.9 (group 2), 264.4 ± 36.5 (group 4), and 245.3 ± 40.7 (group 6) CFUs could be counted in the PSS groups. The difference between the electrolytic approach (test groups 1, 3, and 5) and PSS (control groups 2, 4, and 6) was statistically extremely significant (p-value < 2.2 × 10−16). Conclusion: Only EC inactivated the bacterial biofilm, and PSS left reproducible bacteria behind. Within the limits of this in vitro test, clinical relevance could be demonstrated.
Purpose: The aim of this study is to record material- and surface-dependent heat dissipation during the process of inserting implants into native animal bone. Materials and Methods: Implants made of titanium and zirconium that were identical in macrodesign were inserted under controlled conditions into a bovine rib tempered to 37 °C. The resulting surface temperature was measured on two bone windows by an infrared camera. The results of the six experimental groups, ceramic machined (1), sandblasted (2), and sandblasted and acid-etched surfaces (3) versus titanium implants with the corresponding surfaces (4, 5, and 6) were statistically tested. Results: The average temperature increase, 3 mm subcrestally at ceramic implants, differed with high statistical significance (p = 7.163 × 10−9, resulting from group-adjusted linear mixed-effects model) from titanium. The surface texture of ceramic implants shows a statistical difference between group 3 (15.44 ± 3.63 °C) and group 1 (19.94 ± 3.28 °C) or group 2 (19.39 ± 5.73 °C) surfaces. Within the titanium implants, the temperature changes were similar for all surfaces. Conclusion: Within the limits of an in vitro study, the high temperature rises at ceramic versus titanium implants should be limited by a very slow insertion velocity.