Universitätspublikationen
Refine
Year of publication
- 2020 (16) (remove)
Document Type
- Article (16)
Language
- English (16) (remove)
Has Fulltext
- yes (16) (remove)
Is part of the Bibliography
- no (16)
Keywords
- COVID-19 (2)
- Patient blood management (2)
- (cardiac) surgery (1)
- Children (1)
- Critical care (1)
- Fluid therapy (1)
- Immunomodulatory agents (1)
- Michael acceptor (1)
- Mortality (1)
- Multiplate (1)
Institute
- Medizin (16) (remove)
Introduction: In recent years, resource-saving handling of allogeneic blood products and a reduction of transfusion rates in adults has been observed. However, comparable published national data for transfusion practices in pediatric patients are currently not available. In this study, the transfusion rates for children and adolescents were analyzed based on data from the Federal Statistical Office of Germany during the past 2 decades. Methods: Data were queried via the database of the Federal Statistical Office (Destasis). The period covered was from 2005 to 2018, and those in the sample group were children and adolescents aged 0–17 years receiving inpatient care. Operation and procedure codes (OPS) for transfusions, procedures, or interventions with increased transfusion risk were queried and evaluated in detail. Results: In Germany, 0.9% of the children and adolescents treated in hospital received a transfusion in 2018. A reduction in transfusion rates from 1.02% (2005) to 0.9% (2018) was observed for the total collective of children and adolescents receiving inpatient care. Increases in transfusion rates were recorded for 1- to 4- (1.41–1.45%) and 5- to 10-year-olds (1.24–1.33%). Children under 1 year of age were most frequently transfused (in 2018, 40.2% of the children were cared for in hospital). Transfusion-associated procedures such as chemotherapy or machine ventilation and respiratory support for newborns and infants are on the rise. Conclusion: Transfusion rates are declining in children and adolescents, but the reasons for increases in transfusion rates in other groups are unclear. Prospective studies to evaluate transfusion rates and triggers in children are urgently needed.
Purpose: Trauma is the leading cause of death in children. In adults, blood transfusion and fluid resuscitation protocols changed resulting in a decrease of morbidity and mortality over the past 2 decades. Here, transfusion and fluid resuscitation practices were analysed in severe injured children in Germany.
Methods: Severely injured children (maximum Abbreviated Injury Scale (AIS) ≥ 3) admitted to a certified trauma-centre (TraumaZentrum DGU®) between 2002 and 2017 and registered at the TraumaRegister DGU® were included and assessed regarding blood transfusion rates and fluid therapy.
Results: 5,118 children (aged 1–15 years) with a mean ISS 22 were analysed. Blood transfusion rates administered until ICU admission decreased from 18% (2002–2005) to 7% (2014–2017). Children who are transfused are increasingly seriously injured. ISS has increased for transfused children aged 1–15 years (2002–2005: mean 27.7–34.4 in 2014–2017). ISS in non-transfused children has decreased in children aged 1–15 years (2002–2005: mean 19.6 to mean 17.6 in 2014–2017). Mean prehospital fluid administration decreased from 980 to 549 ml without affecting hemodynamic instability.
Conclusion: Blood transfusion rates and amount of fluid resuscitation decreased in severe injured children over a 16-year period in Germany. Restrictive blood transfusion and fluid management has become common practice in severe injured children. A prehospital restrictive fluid management strategy in severely injured children is not associated with a worsened hemodynamic state, abnormal coagulation or base excess but leads to higher hemoglobin levels.
Background: Approximately one in three patients suffers from preoperative anaemia. Even though haemoglobin is measured before surgery, anaemia management is not implemented in every hospital. Objective: Here, we demonstrate the implementation of an anaemia walk-in clinic at an Orthopedic University Hospital. To improve the diagnosis of iron deficiency (ID), we examined whether reticulocyte haemoglobin (Ret-He) could be a useful additional parameter. Material and Methods: In August 2019, an anaemia walk-in clinic was established. Between September and December 2019, major orthopaedic surgical patients were screened for preoperative anaemia. The primary endpoint was the incidence of preoperative anaemia. Secondary endpoints included Ret-He level, red blood cell (RBC) transfusion rate, in-hospital length of stay and anaemia at hospital discharge. Results: A total of 104 patients were screened for anaemia. Preoperative anaemia rate was 20.6%. Intravenous iron was supplemented in 23 patients. Transfusion of RBC units per patient (1.7 ± 1.2 vs. 0.2 ± 0.9; p = 0.004) and hospital length of stay (13.1 ± 4.8 days vs. 10.6 ± 5.1 days; p = 0.068) was increased in anaemic patients compared to non-anaemic patients. Ret-He values were significantly lower in patients with ID anaemia (33.3 pg [28.6–40.2 pg]) compared to patients with ID (35.3 pg [28.9–38.6 pg]; p = 0.015) or patients without anaemia (35.4 pg [30.2–39.4 pg]; p = 0.001). Conclusion: Preoperative anaemia is common in orthopaedic patients. Our results proved the feasibility of an anaemia walk-in clinic to manage preoperative anaemia. Furthermore, our analysis supports the use of Ret-He as an additional parameter for the diagnosis of ID in surgical patients.
Background: Cerebral O2 saturation (ScO2) reflects cerebral perfusion and can be measured noninvasively by near-infrared spectroscopy (NIRS). Objectives: In this pilot study, we describe the dynamics of ScO2 during TAVI in nonventilated patients and its impact on procedural outcome. Methods and Results: We measured ScO2 of both frontal lobes continuously by NIRS in 50 consecutive analgo-sedated patients undergoing transfemoral TAVI (female 58%, mean age 80.8 years). Compared to baseline ScO2 dropped significantly during RVP (59.3% vs. 53.9%, p < .01). Five minutes after RVP ScO2 values normalized (post RVP 62.6% vs. 53.9% during RVP, p < .01; pre 61.6% vs. post RVP 62.6%, p = .53). Patients with an intraprocedural pathological ScO2 decline of >20% (n = 13) had higher EuroSCORE II (3.42% vs. 5.7%, p = .020) and experienced more often delirium (24% vs. 62%, p = .015) and stroke (0% vs. 23%, p < .01) after TAVI. Multivariable logistic regression revealed higher age and large ScO2 drops as independent risk factors for delirium. Conclusions: During RVP ScO2 significantly declined compared to baseline. A ScO2 decline of >20% is associated with a higher incidence of delirium and stroke and a valid cut-off value to screen for these complications. NIRS measurement during TAVI procedure may be an easy to implement diagnostic tool to detect patients at high risks for cerebrovascular complications and delirium.
Objectives: The ongoing coronavirus pandemic is challenging, especially in severely affected patients who require intubation and sedation. Although the potential benefits of sedation with volatile anesthetics in coronavirus disease 2019 patients are currently being discussed, the use of isoflurane in patients with coronavirus disease 2019–induced acute respiratory distress syndrome has not yet been reported. Design: We performed a retrospective analysis of critically ill patients with hypoxemic respiratory failure requiring mechanical ventilation. Setting: The study was conducted with patients admitted between April 4 and May 15, 2020 to our ICU. Patients: We included five patients who were previously diagnosed with severe acute respiratory syndrome coronavirus 2 infection. Intervention: Even with high doses of several IV sedatives, the targeted level of sedation could not be achieved. Therefore, the sedation regimen was switched to inhalational isoflurane. Clinical data were recorded using a patient data management system. We recorded demographical data, laboratory results, ventilation variables, sedative dosages, sedation level, prone positioning, duration of volatile sedation and outcomes. Measurements & Main Results: Mean age (four men, one women) was 53.0 (± 12.7) years. The mean duration of isoflurane sedation was 103.2 (± 66.2) hours. Our data demonstrate a substantial improvement in the oxygenation ratio when using isoflurane sedation. Deep sedation as assessed by the Richmond Agitation and Sedation Scale was rapidly and closely controlled in all patients, and the subsequent discontinuation of IV sedation was possible within the first 30 minutes. No adverse events were detected. Conclusions: Our findings demonstrate the feasibility of isoflurane sedation in five patients suffering from severe coronavirus disease 2019 infection. Volatile isoflurane was able to achieve the required deep sedation and reduced the need for IV sedation.
Background: The intraoperative blood loss is estimated daily in the operating room and is mainly done by visual techniques. Due to local standards, the surgical sponge colours can vary (e.g. white in US, green in Germany). The influence of sponge colour on accuracy of estimation has not been in the focus of research yet. Material and methods: A blood loss simulation study containing four “bleeding” scenarios each per sponge colour were created by using expired whole blood donation samples. The blood donations were applied to white and green surgical sponges after dilution with full electrolyte solution. Study participants had to estimate the absorbed blood loss in sponges in all scenarios. The difference to the reference blood loss was analysed. Multivariate linear regression analysis was performed to investigate other influence factors such as staff experience and sponge colour. Results: A total of 53 anaesthesists participated in the study. Visual estimation correlated moderately with reference blood loss in white (Spearman's rho: 0.521; p = 3.748*10−16) and green sponges (Spearman's rho: 0.452; p = 4.683*10−12). The median visually estimated blood loss was higher in white sponges (250ml IRQ 150–412.5ml) than in green sponges (150ml IQR 100-300ml), compared to reference blood loss (103ml IQR 86–162.8). For both colour types of sponges, major under- and overestimation was observed. The multivariate statistics demonstrates that fabric colours have a significant influence on estimation (p = 3.04*10−10), as well as clinician’s qualification level (p = 2.20*10−10, p = 1.54*10−08) and amount of RBL to be estimated (p < 2*10−16). Conclusion: The deviation of correct blood loss estimation was smaller with white surgical sponges compared to green sponges. In general, deviations were so severe for both types of sponges, that it appears to be advisable to refrain from visually estimating blood loss whenever possible and instead to use other techniques such as e.g. colorimetric estimation.
Background: Anemia is the most important complication during major surgery and transfusion of red blood cells is the mainstay to compensate for life threating blood loss. Therefore, accurate measurement of hemoglobin (Hb) concentration should be provided in real-time. Blood Gas Analysis (BGA) provides rapid point-of-care assessment using smaller sampling tubes compared to central laboratory (CL) services. Objective: This study aimed to investigate the accuracy of BGA hemoglobin testing as compared to CL services. Methods: Data of the ongoing LIBERAL-Trial (Liberal transfusion strategy to prevent mortality and anemia-associated ischemic events in elderly non-cardiac surgical patients, LIBERAL) was used to assess the bias for Hb level measured by BGA devices (ABL800 Flex analyzer®, GEM series® and RapidPoint 500®) and CL as the reference method. For that, we analyzed pairs of Hb level measured by CL and BGA within two hours. Furthermore, the impact of various confounding factors including age, gender, BMI, smoker status, transfusion of RBC, intraoperative hemodilution, and co-medication was elucidated. In order to ensure adequate statistical analysis, only data of participating centers providing more than 200 Hb pairs were used. Results: In total, three centers including 963 patients with 1,814 pairs of Hb measurements were analyzed. Mean bias was comparable between ABL800 Flex analyzer® and GEM series®: - 0.38 ± 0.15 g/dl whereas RapidPoint 500® showed a smaller bias (-0.09 g/dl) but greater median absolute deviation (± 0.45 g/dl). In order to avoid interference with different standard deviations caused by the different analytic devices, we focused on two centers using the same BGA technique (309 patients and 1,570 Hb pairs). A Bland-Altman analysis and LOWESS curve showed that bias decreased with smaller Hb values in absolute numbers but increased relatively. The smoker status showed the greatest reduction in bias (0.1 g/dl, p<0.001) whereas BMI (0.07 g/dl, p = 0.0178), RBC transfusion (0.06 g/dl, p<0.001), statins (0.04 g/dl, p<0.05) and beta blocker (0.03 g/dl, p = 0.02) showed a slight effect on bias. Intraoperative substitution of volume and other co-medications did not influence the bias significantly. Conclusion: Many interventions like substitution of fluids, coagulating factors or RBC units rely on the accuracy of laboratory measurement devices. Although BGA Hb testing showed a consistently stable difference to CL, our data confirm that BGA devices are associated with different bias. Therefore, we suggest that hospitals assess their individual bias before implementing BGA as valid and stable supplement to CL. However, based on the finding that bias decreased with smaller Hb values, which in turn are used for transfusion decision, we expect no unnecessary or delayed RBC transfusion, and no major impact on the LIBERAL trial performance.
Background: Conditions during blood product storage and transportation should maintain quality. The aim of this in vitro study was to investigate the effect of interruption of agitation, temporary cooling (TC), and pneumatic tube system transportation (PTST) on the aggregation ability (AA) and mitochondrial function (MF) of platelet concentrates (PC).
Study Design and Methods: A PC was divided equally into four subunits and then allocated to four test groups. The control group (I) was stored as recommended (continuous agitation, 22 ± 2°C) for 4 days. The test groups were stored without agitation (II), stored as recommended, albeit 4°C for 60 minutes on day (d)2 (III) and PTST (IV). Aggregometry was measured using Multiplate (RocheAG; ADPtest, ASPItest, TRAPtest, COLtest) and MF using Oxygraph‐2k (Oroboros Instruments). The basal and maximum mitochondrial respiratory rate (MMRR) were determined. AA and MF were measured daily in I and II and AA in III and IV on d2 after TC/PTST. Statistical analysis was performed using tests for matched observations.
Results: Eleven PCs were used. TRAP‐6 induced AA was significantly lower in II when compared to I on d4 (P = 0.015*). In III the ASPItest was significantly lower (P = 0.032*). IV showed no significant differences. The basal and MMRR were significantly reduced over 4 days in I and II (for both rates in both groups: P = <0.0001*). No significant differences occurred on d4 (P = 0.495).
Conclusion: Our results indicate that ex vivo AA and MF of PCs are unaffected, even in no‐ideal storage and transport circumstances with respect to agitation, temperature, and force.