Universitätspublikationen
Refine
Year of publication
- 2021 (32) (remove)
Document Type
- Preprint (32) (remove)
Language
- English (32) (remove)
Has Fulltext
- yes (32)
Is part of the Bibliography
- no (32)
Keywords
- 26 LncRNA (1)
- Acinetobacter baumannii (1)
- Browsertool (1)
- Cannabis (1)
- Data Analysis (1)
- Degradation (1)
- EEG (1)
- Fendrr (1)
- MRI (1)
- Proteomics (1)
- Python (1)
- Software (1)
- TMT (1)
- Translation (1)
- Wnt (1)
- aging (1)
- alpha power (1)
- amyotrophic lateral sclerosis (1)
- chronic (1)
- clinical isolates (1)
- fibroblasts (1)
- frontotemporal dementia (1)
- functional connectome acute (1)
- intracellular (1)
- lung development (1)
- phase separation (1)
- polyQ (1)
- prion-like (1)
- protein aggregation (1)
- pulsed SILAC (1)
- resting-state (1)
- short linear motif (1)
- spinocerebellar ataxia (1)
- stress granules (1)
- trafficking (1)
- triplex (1)
- white matter hyperintensity (1)
Institute
- Medizin (32) (remove)
Recently, a 15-valent (PCV15) and a 20-valent pneumococcal conjugate vaccine (PCV20) have been licensed by the US Food and Drug Administration and are under evaluation by the European Medicines Agency. PCV15 contains all serotypes of the 13-valent conjugate vaccine (PCV13) plus serotype 22F and 33F and PCV20 includes PCV13 serotypes plus serotypes 8, 10A, 11A, 12F, 15B, 22F, 33F. We investigated pneumococcal serotype distribution, secular trends and proportion of pneumonia caused by serotypes included in PCV13, PCV15, PCV20, and the 23-valent pneumococcal polysaccharide vaccine (PPV23) among adult patients with all-cause community-acquired pneumonia (CAP) between 2013 and 2019. We applied logistic mixed regression modelling to assess annual trends. Urine samples from adult patients with CAP treated in the community or hospital in Germany and included in the CAPNETZ study, a prospective multi-centre cohort study, were analysed by two serotype-specific multiplex urinary antigen detection assays (UAD1/UAD2) at Pfizer’s Vaccines Research and Development Laboratory. UAD1 detects serotypes in PCV13, UAD2 detects additional serotypes in PCV20 plus serotypes 2, 9N, 17F and 20. Out of 1,831 patients screened, urine samples with a valid UAD test result were available for 1,343 patients (73.3%). Among those patients, 829 patients (61.7%) were male, 792 patients (59.0%) were aged ≥60 years, 1038 patients (77.3%) had at least one comorbidity and 1,204 patients (89.7%) were treated in the hospital. The overall proportion of vaccine-type pneumonia among all-cause CAP for PCV13, PCV15, PCV20 and PPV23 was 7.7% (n=103), 9.1% (n=122), 12.3% (n=165) and 13.3% (n=178). Over the entire observation period, we did not observe evidence for significant annual trends in pneumococcal vaccine serotype coverage against pneumonia in adults (PCV13: OR 0.94, 95% CI 0.83-1.05; PCV15: OR 0.93, 95% CI 0.84-1.03; PCV20: OR 0.95, 95% CI 0.86-1.04; PPV23: OR 0.99, 95% CI 0.90-1.08). In conclusion, our data show that i) the infant vaccination program of PCV13, which started in Germany 2010 did not result in a relevant and sustained decrease of PCV13 serotypes in pneumonia in adults and ii) that the gap in the coverage between PCV20 and PPV23 was small and did not increase over the entire observation time.
Recently, a 15-valent (PCV15) and a 20-valent pneumococcal conjugate vaccine (PCV20) have been licensed by the US Food and Drug Administration and are under evaluation by the European Medicines Agency. PCV15 contains all serotypes of the 13-valent conjugate vaccine (PCV13) plus serotype 22F and 33F and PCV20 includes PCV13 serotypes plus serotypes 8, 10A, 11A, 12F, 15B, 22F, 33F. We investigated pneumococcal serotype distribution, secular trends and proportion of pneumonia caused by serotypes included in PCV13, PCV15, PCV20, and the 23-valent pneumococcal polysaccharide vaccine (PPV23) among adult patients with all-cause community-acquired pneumonia (CAP) between 2013 and 2019. We applied logistic mixed regression modelling to assess annual trends. Urine samples from adult patients with CAP treated in the community or hospital in Germany and included in the CAPNETZ study, a prospective multi-centre cohort study, were analysed by two serotype-specific multiplex urinary antigen detection assays (UAD1/UAD2) at Pfizer’s Vaccines Research and Development Laboratory. UAD1 detects serotypes in PCV13, UAD2 detects additional serotypes in PCV20 plus serotypes 2, 9N, 17F and 20. Out of 1,831 patients screened, urine samples with a valid UAD test result were available for 1,343 patients (73.3%). Among those patients, 829 patients (61.7%) were male, 792 patients (59.0%) were aged ≥60 years, 1038 patients (77.3%) had at least one comorbidity and 1,204 patients (89.7%) were treated in the hospital. The overall proportion of vaccine-type pneumonia among all-cause CAP for PCV13, PCV15, PCV20 and PPV23 was 7.7% (n=103), 9.1% (n=122), 12.3% (n=165) and 13.3% (n=178). Over the entire observation period, we did not observe evidence for significant annual trends in pneumococcal vaccine serotype coverage against pneumonia in adults (PCV13: OR 0.94, 95% CI 0.83-1.05; PCV15: OR 0.93, 95% CI 0.84-1.03; PCV20: OR 0.95, 95% CI 0.86-1.04; PPV23: OR 0.99, 95% CI 0.90-1.08). In conclusion, our data show i) no decline of PCV13 serotypes in all-cause CAP between 2013-2019 mainly due to a persistently high proportion of serotype 3 suggesting no meaningful effect of childhood PCV13 vaccination on PCV13 coverage in pneumonia in adults during this time period and ii) that the gap in the coverage between PCV20 and PPV23 was small and did not increase over the entire observation time.
Adaptive threshold estimation procedures sample close to a subject’s perceptual threshold by dynamically adapting the stimulation based on the subject’s performance. Yet, perceptual thresholds not only depend on the observers’ sensory capabilities but also on any bias in terms of their expectations and response preferences, thus distorting the precision of the threshold estimates. Using the framework of signal detection theory (SDT), independent estimates of both, an observer’s sensitivity and internal processing bias can be delineated from threshold estimates. While this approach is commonly available for estimation procedures engaging the method of constant stimuli (MCS), correction procedures for adaptive methods (AM) are only scarcely applied. In this article, we introduce a new AM that takes individual biases into account, and that allows for a bias-corrected assessment of subjects’ sensitivity. This novel AM is validated with simulations and compared to a typical MCS-procedure, for which the implementation of bias correction has been previously demonstrated.
Comparing AM and MCS demonstrates the viability of the presented AM. Besides its feasibility, the results of the simulation reveal both, advantages, and limitations of the proposed AM. The procedure has considerable practical implications, in particular for the design of shaping procedures in sensory training experiments, in which task difficulty has to be constantly adapted to an observer’s performance, to improve training efficiency.
The capacity of convalescent and vaccine-elicited sera and monoclonal antibodies (mAb) to neutralize SARS-CoV-2 variants is currently of high relevance to assess the protection against infections.
We performed a cell culture-based neutralization assay focusing on authentic SARS-CoV-2 variants B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.427/B.1.429 (Epsilon), all harboring the spike substitution L452R.
We found that authentic SARS-CoV-2 variants harboring L452R had reduced susceptibility to convalescent and vaccine-elicited sera and mAbs. Compared to B.1, Kappa and Delta showed a reduced neutralization by convalescent sera by a factor of 5.71 and 3.64, respectively, which constitutes a 2-fold greater reduction when compared to Epsilon. BNT2b2 and mRNA1273 vaccine-elicited sera were less effective against Kappa, Delta, and Epsilon compared to B.1. No difference was observed between Kappa and Delta towards vaccine-elicited sera, whereas convalescent sera were 1.6-fold less effective against Delta, respectively. Both B.1.617 variants Kappa (+E484Q) and Delta (+T478K) were less susceptible to either casirivimab or imdevimab.
In conclusion, in contrast to the parallel circulating Kappa variant, the neutralization efficiency of convalescent and vaccine-elicited sera against Delta was moderately reduced. Delta was resistant to imdevimab, which however, might be circumvented by a combination therapy with casirivimab together.
The capacity of convalescent and vaccine-elicited sera and monoclonal antibodies (mAb) to neutralize SARS-CoV-2 variants is currently of high relevance to assess the protection against infections.
We performed a cell culture-based neutralization assay focusing on authentic SARS-CoV-2 variants B.1.617.1 (Kappa), B.1.617.2 (Delta), B.1.427/B.1.429 (Epsilon), all harboring the spike substitution L452R.
We found that authentic SARS-CoV-2 variants harboring L452R had reduced susceptibility to convalescent and vaccine-elicited sera and mAbs. Compared to B.1, Kappa and Delta showed a reduced neutralization by convalescent sera by a factor of 8.00 and 5.33, respectively, which constitutes a 2-fold greater reduction when compared to Epsilon. BNT2b2 and mRNA1273 vaccine-elicited sera were less effective against Kappa, Delta, and Epsilon compared to B.1. No difference was observed between Kappa and Delta towards vaccine-elicited sera, whereas convalescent sera were 1.5-fold less effective against Delta, respectively. Both B.1.617 variants Kappa (+E484Q) and Delta (+T478K) were less susceptible to either casirivimab or imdevimab.
In conclusion, in contrast to the parallel circulating Kappa variant, the neutralization efficiency of convalescent and vaccine-elicited sera against Delta was moderately reduced. Delta was resistant to imdevimab, which however, might be circumvented by a combination therapy with casirivimab together.
The unicellular ciliate Paramecium contains a large vegetative macronucleus with several unusual characteristics including an extremely high coding density and high polyploidy. As macronculear chromatin is devoid of heterochromatin our study characterizes the functional epigenomic organisation necessary for gene regulation and proper PolII activity. Histone marks (H3K4me3, H3K9ac, H3K27me3) revealed no narrow peaks but broad domains along gene bodies, whereas intergenic regions were devoid of nucleosomes. Our data implicates H3K4me3 levels inside ORFs to be the main factor to associate with gene expression and H3K27me3 appears to occur as a bistable domain with H3K4me3 in plastic genes. Surprisingly, silent and lowly expressed genes show low nucleosome occupancy suggesting that gene inactivation does not involve increased nucleosome occupancy and chromatin condensation. Due to a high occupancy of Pol II along highly expressed ORFs, transcriptional elongation appears to be quite different to other species. This is supported by missing heptameric repeats in the C-terminal domain of Pol II and a divergent elongation system. Our data implies that unoccupied DNA is the default state, whereas gene activation requires nucleosome recruitment together with broad domains of H3K4me3. This could represent a buffer for paused Pol II along ORFs in absence of elongation factors of higher eukaryotes.
The coronavirus SARS-CoV-2 is the cause of the ongoing COVID-19 pandemic. Most SARS-CoV-2 infections are mild or even asymptomatic. However, a small fraction of infected individuals develops severe, life-threatening disease, which is caused by an uncontrolled immune response resulting in hyperinflammation. Antiviral interventions are only effective prior to the onset of hyperinflammation. Hence, biomarkers are needed for the early identification and treatment of high-risk patients. Here, we show in a range of model systems and data from post mortem samples that SARS-CoV-2 infection results in increased levels of CD47, which is known to mediate immune escape in cancer and virus-infected cells. Systematic literature searches also indicated that known risk factors such as older age and diabetes are associated with increased CD47 levels. High CD47 levels contribute to vascular disease, vasoconstriction, and hypertension, conditions which may predispose SARS-CoV-2-infected individuals to COVID-19-related complications such as pulmonary hypertension, lung fibrosis, myocardial injury, stroke, and acute kidney injury. Hence, CD47 is a candidate biomarker for severe COVID-19. Further research will have to show whether CD47 is a reliable diagnostic marker for the early identification of COVID-19 patients requiring antiviral therapy.
Mosquito species belonging to the genus Aedes have attracted the interest of scientists and public health officers for their invasive species traits and efficient capacity of transmitting viruses affecting humans. Some of these species were brought outside their native range by human activities such as trade and tourism, and colonised new regions thanks to a unique combination of eco-physiological traits.
Considering mosquito physiological and behavioural traits to understand and predict the spatial and temporal population dynamics is thus a crucial step to develop strategies to mitigate the local densities of invasive Aedes populations.
Here, we synthesised the life cycle of four invasive Aedes species (Ae. aegypti, Ae. albopictus, Ae. japonicus and Ae. koreicus) in a single multi-scale stochastic modelling framework which we coded in the R package dynamAedes. We designed a stage-based and time-discrete stochastic model driven by temperature, photo-period and inter-specific larval competition that can be applied to three different spatial scales: punctual, local and regional. These spatial scales consider different degrees of spatial complexity and data availability, by accounting for both active and passive dispersal of mosquito species as well as for the heterogeneity of the input temperature data.
Our overarching aim was to provide a flexible, open-source and user-friendly tool rooted in the most updated knowledge on species biology which could be applied to the management of invasive Aedes populations as well as for more theoretical ecological inquiries.
The measurement of protein dynamics by proteomics to study cell remodeling has seen increased attention over the last years. This development is largely driven by a number of technological advances in proteomics methods. Pulsed stable isotope labeling in cell culture (SILAC) combined with tandem mass tag (TMT) labeling has evolved as a gold standard for profiling protein synthesis and degradation. While the experimental setup is similar to typical proteomics experiments, the data analysis proves more difficult: After peptide identification through search engines, data extraction requires either custom scripted pipelines or tedious manual table manipulations to extract the TMT-labeled heavy and light peaks of interest. To overcome this limitation, which deters researchers from using protein dynamic proteomics, we developed a user-friendly, browser-based application that allows easy and reproducible data analysis without the need for scripting experience. In addition, we provide a python package that can be implemented in established data analysis pipelines. We anticipate that this tool will ease data analysis and spark further research aimed at monitoring protein translation and degradation by proteomics.
Electrocardiograms (ECG) record the heart activity and are the most common and reliable method to detect cardiac arrhythmias, such as atrial fibrillation (AFib). Lately, many commercially available devices such as smartwatches are offering ECG monitoring. Therefore, there is increasing demand for designing deep learning models with the perspective to be physically implemented on these small portable devices with limited energy supply. In this paper, a workflow for the design of small, energy-efficient recurrent convolutional neural network (RCNN) architecture for AFib detection is proposed. However, the approach can be well generalized to every type of long time series. In contrast to previous studies, that demand thousands of additional network neurons and millions of extra model parameters, the logical steps for the generation of a CNN with only 114 trainable parameters are described. The model consists of a small segmented CNN in combination with an optimal energy classifier. The architectural decisions are made by using the energy consumption as a metric in an equally important way as the accuracy. The optimisation steps are focused on the software which can be embedded afterwards on a physical chip. Finally, a comparison with some previous relevant studies suggests that the widely used huge CNNs for similar tasks are mostly redundant and unessentially computationally expensive.