Universitätspublikationen
Refine
Document Type
- Article (2)
Language
- English (2) (remove)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- ACURATE neo (1)
- Aortic valve (1)
- Blood pressure (1)
- Body mass index (1)
- Chronic obstructive pulmonary disease (1)
- Death rates (1)
- Ejection fraction (1)
- Heart failure (1)
- Prognosis (1)
- TAVR (1)
Institute
- Medizin (2) (remove)
Aims: Patients with aortic stenosis (AS) may have concomitant heart failure (HF) that determines prognosis despite successful transcatheter aortic valve implantation (TAVI). We compared outcomes of TAVI patients with low stroke volume index (SVI) ≤35 ml/m2 body surface area in different HF classes.
Methods and results: Patients treated by transfemoral TAVI at our center (n = 1822) were classified as 1) ‘HF with preserved ejection fraction (EF)’ (HFpEF, EF ≥50%), 2) ‘HF with mid-range EF’ (HFmrEF, EF 40–49%), or 3) ‘HF with reduced EF’ (HFrEF, EF <40%). Patients with SVI >35 ml/m2 served as controls. The prevalence of cardiovascular disease and symptoms increased stepwise from controls (n = 968) to patients with HFpEF (n = 591), HFmrEF (n = 97), and HFrEF (n = 166). Mortality tended to be highest in HFrEF patients 30 days post-procedure, and it became significant after one year: 10.2% (controls), 13.5% (HFpEF), 13.4% (HFmrEF), and 23.5% (HFrEF). However, symptomatic improvement in survivors of all groups was achieved in the majority of patients without differences among groups.
Conclusions: Patients with AS and HF benefit from TAVI with respect to symptom alleviation. TAVI in patients with HFpEF and HFmrEF led to an identical, favorable post-procedural prognosis that was significantly better than that of patients with HFrEF, which remains a high-risk population.
Objectives: The SAVI-TF (Symetis ACURATE neo Valve Implantation Using Transfemoral Access) registry was initiated to study the ACURATE neo transcatheter heart valve in a large patient population treated under real-world conditions.
Background: The self-expanding, supra-annular ACURATE neo prosthesis is a transcatheter heart valve that gained the Conformité Européene mark in 2014, but only limited clinical data are available so far.
Methods: This prospective, multicenter registry enrolled 1,000 patients at 25 European centers who were followed for 1 year post-procedure.
Results: Mean patient age was 81.1 ± 5.2 years; mean logistic European System for Cardiac Operative Risk Evaluation I score, European System for Cardiac Operative Risk Evaluation II score, and Society of Thoracic Surgeons score were 18.1 ± 12.5%, 6.6 ± 7.5%, and 6.0 ± 5.6%, respectively. At 1 year, 8.0% (95% confidence interval [CI]: 6.3% to 9.7%) of patients had died, 2.3% (95% CI: 1.3% to 3.2%) had disabling strokes, and 9.9% (95% CI: 8.1% to 11.8%) had permanent pacemaker implantations. Through 1 year, 5 reinterventions (0.5%; 95% CI: 0.1% to 1.0%) were performed: 3 valve-in-valve and 2 surgical aortic valve replacements. Mean effective orifice area was 1.84 ± 0.43 cm2, mean gradient was 7.3 ± 3.7 mm Hg, and greater than mild paravalvular leakage was observed in 3.6% of patients.
Conclusions: Transfemoral implantation of the ACURATE neo prosthesis resulted in favorable 1-year clinical and echocardiographic outcomes with very low mortality and new pacemaker rates.