Universitätspublikationen
Refine
Document Type
- Article (15) (remove)
Language
- English (15)
Has Fulltext
- yes (15)
Is part of the Bibliography
- no (15)
Keywords
- Acute myeloid leukemia (4)
- AML (3)
- Induction chemotherapy (3)
- Survival (3)
- Chemotherapy (2)
- Intensive care treatment (2)
- induction chemotherapy (2)
- ADAMTS13 (1)
- Acute kidney failure (1)
- Antibiotic steward-ship (1)
Institute
- Medizin (15) (remove)
Objectives and Methods: Intracranial hemorrhage (ICH) in acute myeloid leukemia (AML) patients is a major concern due to the increased risk of mortality. Few studies have examined ICH specifically in newly diagnosed AML patients receiving intensive induction chemotherapy (IC) and prophylactic platelet transfusions during thrombocytopenia <10/nL. This retrospective cohort study included 423 newly diagnosed AML patients without acute promyelocytic leukemia who underwent IC between 2007 and 2019. We assessed risk factors, clinical features, and outcomes of ICH.
Results: 17 of 423 patients (4%) suffered ICH during hospital stay, and 4 patients (24%) died directly because of ICH despite routine prophylactic platelet transfusions. Patients with ICH had a negatively impacted overall survival (median OS, 20.1 vs. 104.8 months) and were more likely not to continue with curative treatment. Main risk factors were female gender, severe thrombocytopenia, and decreased fibrinogen. Patients with subsequent ICH also had laboratory signs of liver dysfunction.
Conclusions: Intracranial hemorrhage remains a potentially deadly complication with notable incidence despite prophylactic platelet substitution, suggesting that additional prophylactic interventions may be required to further reduce the frequency of ICH in high-risk patients. Unrecognized genetic factors may simultaneously predispose to AML and platelet dysfunction with ICH.
Introduction: Cancer patients tend to prefer oral instead of parenteral chemotherapy. To date, there is little evidence on the medication adherence in cancer patients. We investigated medication adherence to tyrosine kinase inhibitors in patients suffering from non-small cell lung cancer. Methods: Tyrosine kinase inhibitor adherence was measured electronically by MEMS® (medication event monitoring system) over at least six months. Adherence rates were calculated in terms of Dosing Compliance, Timing Compliance, Taking Compliance, and Drug Holidays. Patients were dichotomized as adherent when Dosing Compliance and Timing Compliance were ≥80%, Taking Compliance ranged between 90 and 110%, and <1 Drug Holiday was registered. Quality of life was assessed by two questionnaires (EORTC QLQ-C30 version 3.0, EORTC QLQ-LC13) at three time points. Adverse drug events were reported via patient diaries. Results: Out of 32 patients enrolled, data from 23 patients were evaluable. Median Dosing Compliance, Taking Compliance, and Timing Compliance adherence rates of tyrosine kinase inhibitor intake amounted to 100%, 98%, and 99%, respectively; Drug Holidays were observed in three patients. Four patients were dichotomized as non-adherent. Three of them had a twice-daily tyrosine kinase inhibitor regimen. Median quality of life scores amounted to 67 (max. 100) and remained unchanged over the study period. Fatigue and rash were the most frequently reported adverse drug events. Conclusion: Medication adherence of non-small cell lung cancer patients treated with tyrosine kinase inhibitors was extraordinarily high and is likely to support the effectiveness of tyrosine kinase inhibitor treatment and a good quality of life over a long period of time. Adherence facilitating information and education is especially relevant for patients taking tyrosine kinase inhibitors in a twice-daily regimen.
Platelet function (PF) plays a pivotal role in both hemostasis and thrombosis, and manual light transmission aggregometry (LTA) is considered the standard of care for platelet function testing but is an error-prone and time-consuming procedure. We aimed to test the agreement regarding maximum aggregation (MA), velocity (VEL), and lag-phase (LagP) of platelet aggregation of the automated Sysmex CS-2100i analyzer (Siemens, Germany) against the APACT 4004 (Elitech, France) in samples derived from healthy participants and patients with hemostaseologic disorders. In total, 123 patient-derived samples were investigated, including 42 patients with acetylsalicylic acid and/or clopidogrel intake and 20 patients with other hemostaseologic disorders. Both MA and VEL showed good or excellent intermethod correlation. Agreement between the testing methods was only partially achieved, and values were indicative for a systematic bias to lower measurements below a threshold of 50% MA with the CS-2100i compared to the APACT 4004. All patients with impaired PF in the APACT 4004 were successfully identified with the CS-2100i, and reference values for automated LTA are provided. Conclusively, automated LTA with the CS-2100i is a highly standardized and reliable PF testing method and represents a decisive step in the simplification of platelet function testing in clinical routine.
Objectives: Multidrug-resistant organisms (MDRO) are considered an emerging threat worldwide. Data covering the clinical impact of MDRO colonization in patients with solid malignancies, however, is widely missing. We sought to determine the impact of MDRO colonization in patients who have been diagnosed with Non-small cell lung cancer (NSCLC) who are at known high-risk for invasive infections.
Materials and methods: Patients who were screened for MDRO colonization within a 90-day period after NSCLC diagnosis of all stages were included in this single-center retrospective study.
Results: Two hundred and ninety-five patients were included of whom 24 patients (8.1%) were screened positive for MDRO colonization (MDROpos) at first diagnosis. Enterobacterales were by far the most frequent MDRO detected with a proportion of 79.2% (19/24). MDRO colonization was present across all disease stages and more present in patients with concomitant diabetes mellitus. Median overall survival was significantly inferior in the MDROpos study group with a median OS of 7.8 months (95% CI, 0.0–19.9 months) compared to a median OS of 23.9 months (95% CI, 17.6–30.1 months) in the MDROneg group in univariate (p = 0.036) and multivariate analysis (P = 0.02). Exploratory analyses suggest a higher rate of non-cancer-related-mortality in MDROpos patients compared to MDROneg patients (p = 0.002) with an increased rate of fatal infections in MDROpos patients (p = 0.0002).
Conclusions: MDRO colonization is an independent risk factor for inferior OS in patients diagnosed with NSCLC due to a higher rate of fatal infections. Empirical antibiotic treatment approaches should cover formerly detected MDR commensals in cases of (suspected) invasive infections.
Evaluation of a rapid turn-over, fully-automated ADAMTS13 activity assay: a method comparison study
(2020)
Thrombotic thrombocytopenic purpura (TTP) is a life-threatening thrombotic microangiopathy caused by severely reduced activity of the von-Willebrand factor-cleaving protease ADAMTS13, mainly caused by anti-ADAMTS-13 antibodies. Although several test systems for ADAMTS13 measurement exist, long turn-around times hamper the usability in daily practice. We performed a method comparison study for two commercially available ADAMTS13 assays and evaluated the agreement between the fully-automated rapid turn-over HemosIL AcuStar ADAMTS13 Activity assay and the manually performed TECHNOZYM ADAMTS-13 Activity assay. Twenty-four paired test samples derived from 10 consecutively recruited patients (n = 8, acquired TTP; n = 1, atypical hemolytic uremic syndrome; n = 1, control), of which nine test samples were collected in case of clinically apparent TTP and 13 samples were collected from TTP patients in clinical remission were included. Overall correlation between the TECHNOZYM and AcuStar assay was good with a Pearson R of 0.93 (p < 0.001). Agreement between the assays assessed with the Passing–Bablok analysis showed high agreement with an Intercept of − 2.56 (95% confidence interval [CI], − 5.07 to − 0.86) and Slope of 1.04 (95% CI 0.84–1.17). The absolute mean bias was 2.54% (standard difference [SD], 6.38%; 95% CI to 10.0–15.05%). Intra-method reliability was high with an absolute mean bias of − 0.13% (SD 3.21%; 95% CI to 6.42–6.16%). The observer agreement for categorial thresholds (> or < 10% ADAMTS3 activity) was kappa = 0.82 (95% CI 0.59–1.0). Conclusively, overall agreement between the testing methods was sufficient and we support previously published data suggesting the AcuStar assay being a valuable and accurate tool for ADAMTS13 activity testing and TTP diagnostics.