Medizin
Refine
Document Type
- Article (4) (remove)
Language
- English (4)
Has Fulltext
- yes (4)
Is part of the Bibliography
- no (4)
Keywords
Institute
- Medizin (4)
We present the case of an adult male patient with an incomplete form of Shone’s complex associated with bicuspid aortic valve and a double orifice mitral valve. Intraoperative inspection of the mitral valve showed double orifice configuration with a small, rudimentary left-sided mitral valve and a large, dominant, right-sided parachute mitral valve with Barlow-type of degeneration. The patient underwent reconstruction of both valves through a minimally invasive incision. At one year echocardiographic control both valves function normally.
Changes of left ventricular systolic function in patients undergoing coronary artery bypass grafting
(2019)
AIM: This prospective study was designed to evaluate the changes in left ventricular (LV) systolic function after coronary artery bypass grafting (CABG) in patients with both normal and abnormal pre-operative systolic function. METHODS: During the period from October 2017 to October 2018, forty-seven consecutive patients undergoing CABG were enrolled in this prospective study. Transthoracic echocardiography was performed within 1 week before CABG as well as 4 to 6 months after surgery. All measurements were made by a single experienced investigator. RESULTS: While the mean LV ejection fraction (LVEF) showed neither improvement nor significant reduction in the whole group of patients following CABG (from 54.21 ± 15.36 to 53.66 ± 11.56%, p = 0.677), significant improvement in LVEF was detected in the subgroup of patients with pre-operative LV dysfunction (from 40.05 ± 8.65 to 45.85 ± 9.04%, p = 0.008). On the other hand, there was a significant decline in LEFT in the subgroup of patients with normal pre-operative LEFT (from 64.70 ± 9.72 to 59.44 ± 9.75%, p = 0.008). As for the other parameters of systolic function, significant decrease in LV end-diastolic volume index (LVEDVI) (p = 0.001), LV end-systolic volume index (LVESVI) (p = 0.0001), wall motion score index (WMSI) (p = 0.013) and LVmass index in male patients (p = 0.011) was shown only in patients with decreased LVEF after CABG. Patients with improved postoperative LVEF (53.2% of all patients) had significantly lower baseline LVEF (p = 0.0001), higher LVESVI (0.009) and higher WMSI (p = 0.006) vs patients with worsened postoperative LVEF (38.3% of all patients). Postoperative improvement of LVEF was correlated with stabile angina, lack of preoperative myocardial infarction and smoking, higher baseline WMSI, higher LV internal diameters and indexed volumes in diastole and systole and lower baseline LVEF. In stepwise linear regression analysis the value of baseline LVEF appeared as independent predictor of improved LVEF after CABG (B = 0,836%; 95% CI 0.655-1.017; p = 0.0001). CONCLUSION: Our study showed that LVEF, internal baseline diameters and indexed volumes of LV in diastole and systole are important determinants of postoperative change in LVEF. In patients with preoperative depressed myocardial function, there is an improvement in systolic function, whereas in patients with preserved preoperative myocardial function, the decline in postoperative LVEF was detected.
The radial artery as a conduit for coronary artery bypass grafting : review of current knowledge
(2006)
The effect of coronary artery bypass grafting (CABG) lasts as long as the grafts are patent. The internal mammary artery has been considered the "golden" graft due to the superb long-term patency, exceeding 90% at 10 years. The saphenous vein grafts, unfortunately, tend to occlude with a rate of 10-15% within a year after surgery, and eventually, at 10 years after the operation, as much as 60-70% of these vein grafts are either occluded or have angiographic evidence of atherosclerosis. The search for another "arterial conduit", the radial artery, has intensified through the last 15 years in hope to provide a better graft than the saphenous vein for CABG. This article reviews the current knowledge for the radial artery as a conduit in CABG. (Anadolu Kardiyol Derg 2006; 6: 153-62)
Left ventricular non-compaction cardiomyopathy and left ventricular assist device: a word of caution
(2016)
BACKGROUND: In patients with left ventricular non-compaction (LVNC), implantation of a left ventricular assist device (LVAD) may be performed as a bridge to transplantation. In this respect, the particular characteristics of the left ventricular myocardium may represent a challenge.
CASE PRESENTATION: We report a patient with LVNC who required urgent heart transplantation for inflow cannula obstruction nine months after receiving a LVAD. LVAD parameters, echocardiography and examination of the explanted heart suggested changes of left ventricular configuration brought about by LVAD support as the most likely cause of inflow cannula obstruction.
CONCLUSIONS: We conclude that changes experienced by non-compacted myocardium during LVAD support may give rise to inflow cannula obstruction and flow reduction. Presence of LVNC mandates tight surveillance for changes in LV configuration and LVAD flow characteristics and may justify urgent transplantation listing status.