We present the case of an adult male patient with an incomplete form of Shone’s complex associated with bicuspid aortic valve and a double orifice mitral valve. Intraoperative inspection of the mitral valve showed double orifice configuration with a small, rudimentary left-sided mitral valve and a large, dominant, right-sided parachute mitral valve with Barlow-type of degeneration. The patient underwent reconstruction of both valves through a minimally invasive incision. At one year echocardiographic control both valves function normally.
Background: Rates of permanent pacemaker implantation (PPI) have been low using the self‐expanding ACURATE neo device, but data regarding risk factors of PPI for this specific device are scarce.
Methods: The study cohort consisted of patients (n = 1000) with severe aortic stenosis undergoing transfemoral transcatheter aortic valve implantation (TAVI) using the ACURATE neo prosthesis in our center between May 2012 and December 2019. For the present analysis, we excluded patients with previous permanent pacemaker (n = 110), high‐grade AV block prior to TAVI (n = 3), and patients requiring conversion to surgical valve replacement (n = 4) or the implantation of a second prosthesis as valve‐in‐valve (n = 15). Preexisting conduction abnormalities were determined, and the implantation depth of the prosthesis was measured on final angiography. Differences across quartiles based on the original consecutive cohort were analyzed with respect to implantation depth and PPI rate. Predictors of PPI were identified using logistic regression.
Results: The PPI rate was 10%. Preexisting AV block I°, right bundle branch block (RBBB), and the implantation depth were independent predictors of PPI. Across quartiles, the implantation depth differed significantly with lowest values in the last quartile, whereas differences of PPI rates across quartiles were not statistically significant, but showed a notable decrease in the last quartile.
Conclusion: Preexisting RBBB, AV block I°, and low implantation depth were independent predictors of PPI following TAVI using the ACURATE neo device. Instead of deliberately aiming at a high position, avoidance of a low implantation depth may represent a reasonable compromise to reduce the rate of PPI without increasing the risk of malpositioning.
Objective: To determine the impact of an exercise-based prehabilitation (EBPrehab) program on preand postoperative exercise capacity, functional capacity (FC) and quality of life (QoL) in patients awaiting elective coronary artery bypass graft surgery (CABG).
Design: A two-group randomized controlled trail.
Setting: Ambulatory prehabilitation.
Subjects: Overall 230 preoperative elective CABG-surgery patients were randomly assigned to an intervention (IG, n=88; n=27 withdrew after randomization) or control group (CG, n=115).
Intervention: IG: two-week EBPrehab including supervised aerobic exercise. CG: usual care.
Main measures: At baseline (T1), one day before surgery (T2), at the beginning (T3) and at the end of cardiac rehabilitation (T4) the following measurements were performed: cardiopulmonary exercise test, six-minute walk test (6MWT), Timed-Up-and-Go Test (TUG) and QoL (MacNew questionnaire).
Results: A total of 171 patients (IG, n=81; CG, n=90) completed the study. During EBPrehab no complications occurred. Preoperatively FC (6MWTIG: 443.0±80.1m to 493.5±75.5m, P=0.003; TUGIG: 6.9±2.0 s to 6.1±1.8 s, P=0.018) and QoL (IG: 5.1±0.9 to 5.4±0.9, P<0.001) improved significantly more in IG compared to CG. Similar effects were observed postoperatively in FC (6MWDIG: Δ-64.7m, pT1–T3=0.013; Δ+47.2m, pT1–T4<0.001; TUGIG: Δ+1.4s, pT1–T3=0.003).
Conclusions: A short-term EBPrehab is effective to improve perioperative FC and preoperative QoL in patients with stable coronary artery disease awaiting CABG-surgery.
Background. Transcatheter aortic valve implantation (TAVI) is currently recommended for patients with severe aortic stenosis at intermediate or high surgical risk. The decision process during TAVI evaluation includes a thorough benefit-risk assessment, and knowledge about long-term benefits and outcomes may improve patients’ expectation management. Objective. To evaluate patients’ perceived health status and self-reported long-term outcome more than 5 years after TAVI. Methods and Results. Demographic and procedure data were obtained from all patients treated with TAVI at our institution from 2006 to 2012. A cross-sectional survey was conducted on the patients alive, measuring health status, including the EQ-5D-5L questionnaire, and clinical outcomes. 103 patients (22.8%) were alive at a median follow-up period of 7 years (5.4–9.8). 99 (96%) of the 103 patients were included in the final analysis. The mean age at follow-up was 86.5 years ± 8.0 years, and 56.6% were female. Almost all patients (93.9%) described an improvement of their quality of life after receiving TAVI. At late follow-up, the mean utility index and EQ-VAS score were 0.80 ± 0.20 and 58.49 ± 11.49, respectively. Mobility was found to be the most frequently reported limitation (85.4%), while anxiety/depression was the least frequently reported limitation (19.8%). With respect to functional class, 64.7% were in New York Heart Association (NYHA) class III or IV, compared to 67.0% prior to TAVI (p = 0.51). Self-reported long-term outcomes revealed mainly low long-term complication rates. 74 total hospitalizations were reported after TAVI, and among those 43% for cardiovascular reasons. Within cardiovascular rehospitalizations, new pacemaker implantations were the most frequently reported (18.9%), followed by cardiac decompensation and coronary heart disease (15.6%). Conclusion. The majority of the patients described an improvement of health status after TAVI. More than five years after TAVI, the patients’ perceived health status was satisfactory, and the incidence of clinical events and hospitalizations was very low.
Aims: Patients with aortic stenosis (AS) may have concomitant heart failure (HF) that determines prognosis despite successful transcatheter aortic valve implantation (TAVI). We compared outcomes of TAVI patients with low stroke volume index (SVI) ≤35 ml/m2 body surface area in different HF classes.
Methods and results: Patients treated by transfemoral TAVI at our center (n = 1822) were classified as 1) ‘HF with preserved ejection fraction (EF)’ (HFpEF, EF ≥50%), 2) ‘HF with mid-range EF’ (HFmrEF, EF 40–49%), or 3) ‘HF with reduced EF’ (HFrEF, EF <40%). Patients with SVI >35 ml/m2 served as controls. The prevalence of cardiovascular disease and symptoms increased stepwise from controls (n = 968) to patients with HFpEF (n = 591), HFmrEF (n = 97), and HFrEF (n = 166). Mortality tended to be highest in HFrEF patients 30 days post-procedure, and it became significant after one year: 10.2% (controls), 13.5% (HFpEF), 13.4% (HFmrEF), and 23.5% (HFrEF). However, symptomatic improvement in survivors of all groups was achieved in the majority of patients without differences among groups.
Conclusions: Patients with AS and HF benefit from TAVI with respect to symptom alleviation. TAVI in patients with HFpEF and HFmrEF led to an identical, favorable post-procedural prognosis that was significantly better than that of patients with HFrEF, which remains a high-risk population.
Prevalence of non-alcoholic fatty liver disease (NAFLD) is increasing. Resulting fibrosis and portal hypertension, as a possible secondary event, may necessitate treatment. Overexpression of mouse renin in the transgenic rat model, TGR(mREN2)27, leads to spontaneous development of NAFLD. Therefore, we used TGR(mREN2)27 rats as a model of NAFLD where we hypothesized increased susceptibility and investigated fibrosis and portal hypertension and associated pathways. 12-week old TGR(mREN2)27 rats received either cholestatic (BDL) or toxic injury (CCl4 inhalation). Portal and systemic hemodynamic assessments were performed using microsphere technique with and without injection of the Janus-Kinase 2 (JAK2) inhibitor AG490 or the non-peptidic Ang(1-7) agonist, AVE0991. The extent of liver fibrosis was assessed in TGR(mREN2)27 and wild-type rats using standard techniques. Protein and mRNA levels of profibrotic, renin-angiotensin system components were assessed in liver and primary hepatic stellate cells (HSC) and hepatocytes. TGR(mREN2)27 rats developed spontaneous, but mild fibrosis and portal hypertension due to the activation of the JAK2/Arhgef1/ROCK pathway. AG490 decreased migration of HSC and portal pressure in isolated liver perfusions and in vivo. Fibrosis or portal hypertension after cholestatic (BDL) or toxic injury (CCl4) was not aggravated in TGR(mREN2)27 rats, probably due to decreased mouse renin expression in hepatocytes. Interestingly, portal hypertension was even blunted in TGR(mREN2)27 rats (with or without additional injury) by AVE0991. TGR(mREN2)27 rats are a suitable model of spontaneous liver fibrosis and portal hypertension but not with increased susceptibility to liver damage. After additional injury, the animals can be used to evaluate novel therapeutic strategies targeting Mas.
Objectives: The SAVI-TF (Symetis ACURATE neo Valve Implantation Using Transfemoral Access) registry was initiated to study the ACURATE neo transcatheter heart valve in a large patient population treated under real-world conditions.
Background: The self-expanding, supra-annular ACURATE neo prosthesis is a transcatheter heart valve that gained the Conformité Européene mark in 2014, but only limited clinical data are available so far.
Methods: This prospective, multicenter registry enrolled 1,000 patients at 25 European centers who were followed for 1 year post-procedure.
Results: Mean patient age was 81.1 ± 5.2 years; mean logistic European System for Cardiac Operative Risk Evaluation I score, European System for Cardiac Operative Risk Evaluation II score, and Society of Thoracic Surgeons score were 18.1 ± 12.5%, 6.6 ± 7.5%, and 6.0 ± 5.6%, respectively. At 1 year, 8.0% (95% confidence interval [CI]: 6.3% to 9.7%) of patients had died, 2.3% (95% CI: 1.3% to 3.2%) had disabling strokes, and 9.9% (95% CI: 8.1% to 11.8%) had permanent pacemaker implantations. Through 1 year, 5 reinterventions (0.5%; 95% CI: 0.1% to 1.0%) were performed: 3 valve-in-valve and 2 surgical aortic valve replacements. Mean effective orifice area was 1.84 ± 0.43 cm2, mean gradient was 7.3 ± 3.7 mm Hg, and greater than mild paravalvular leakage was observed in 3.6% of patients.
Conclusions: Transfemoral implantation of the ACURATE neo prosthesis resulted in favorable 1-year clinical and echocardiographic outcomes with very low mortality and new pacemaker rates.
It is now accepted that heart failure (HF) is a complex multifunctional disease rather than simply a hemodynamic dysfunction. Despite its complexity, stressed cardiomyocytes often follow conserved patterns of structural remodelling in order to adapt, survive, and regenerate. When cardiac adaptations cannot cope with mechanical, ischemic, and metabolic loads efficiently or become chronically activated, as, for example, after infection, then the ongoing structural remodelling and dedifferentiation often lead to compromised pump function and patient death. It is, therefore, of major importance to understand key events in the progression from a compensatory left ventricular (LV) systolic dysfunction to a decompensatory LV systolic dysfunction and HF. To achieve this, various animal models in combination with an “omics” toolbox can be used. These approaches will ultimately lead to the identification of an arsenal of biomarkers and therapeutic targets which have the potential to shape the medicine of the future.