• search hit 5 of 5
Back to Result List

Individualized mould-based high-dose-rate brachytherapy for perinasal skin tumors: technique evaluation from a dosimetric point of view

  • Purpose: Dosimetric treatment planning evaluations concerning patient-adapted moulds for iridium-192 highdose-rate brachytherapy are presented in this report. Material and methods: Six patients with perinasal skin tumors were treated with individual moulds made of biocompatible epithetic materials with embedded plastic applicators. Treatment plans were optimized with regard to clinical requirements, and dose was calculated using standard water-based TG-43 formalism. In addition, retrospective material-dependent collapsed cone calculations according to TG-186 protocol were evaluated to quantify the limitations of TG-43 protocol for this superficial brachytherapy technique. Results: The dose-volume parameters D90, V100, and V150 of the planning target volumes (PTVs) for TG-43 dose calculations yielded 92.2% to 102.5%, 75.1% to 93.1%, and 7.4% to 41.7% of the prescribed dose, respectively. The maximum overall dose to the ipsilateral eyeball as the most affected organ at risk (OAR) varied between 8.9 and 36.4 Gy. TG-186 calculations with Hounsfield unit-based density allocation resulted in down by –6.4%, –16.7%, and –30.0% lower average D90, V100, and V150 of the PTVs, with respect to the TG-43 data. The corresponding calculated OAR doses were also lower. The model-based TG-186 dose calculations have considered reduced backscattering due to environmental air as well as the dose-to-medium influenced by the mould materials and tissue composition. The median PTV dose was robust within 0.5% for simulated variations of mould material densities in the range of 1.0 g/cm³ to 1.26 g/cm³ up to 7 mm total mould thickness. Conclusions: HDR contact BT with individual moulds is a safe modality for routine treatment of perinasal skin tumors. The technique provides good target coverage and OARs’ protection, while being robust against small variances in mould material density. Model-based dose calculations (TG-186) should complement TG-43 dose calculations for verification purpose and quality improvement.

Download full text files

Export metadata

Metadaten
Author:Christian ScherfORCiD, Jörg LicherGND, Christina Mletzko, Martin Trommel, Nikolaos TselisGND, Georgios ChatzikonstantinouORCiDGND, Markus DiefenhardtORCiDGND, Claus RödelORCiDGND, Janett KöhnGND, Ulla Ramm
URN:urn:nbn:de:hebis:30:3-629418
DOI:https://doi.org/10.5114/jcb.2021.105286
ISSN:2081-2841
Parent Title (English):Journal of contemporary brachytherapy
Publisher:Termedia
Place of publication:Poznań
Document Type:Article
Language:English
Date of Publication (online):2021/04/14
Date of first Publication:2021/04/14
Publishing Institution:Universitätsbibliothek Johann Christian Senckenberg
Release Date:2023/08/02
Tag:TG-186; TG-43; brachytherapy; individual moulds; perinasal skin cancer
Volume:13
Issue:2
Page Number:9
First Page:179
Last Page:187
HeBIS-PPN:512573069
Institutes:Medizin / Medizin
Dewey Decimal Classification:6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Sammlungen:Universitätspublikationen
Licence (German):License LogoCreative Commons - CC BY-NC-SA - Namensnennung - Nicht kommerziell - Weitergabe unter gleichen Bedingungen 4.0 International