Institute
Filtern
Dokumenttyp
Sprache
- Englisch (3)
Volltext vorhanden
- ja (3)
Gehört zur Bibliographie
- nein (3)
Schlagworte
- Autoimmune response (1)
- DMEK (1)
- Fuchs endothelial dystrophy (1)
- Ocular tuberculosis (1)
- Phlyctenule (1)
- Scheimpflug imaging (1)
- Scrofulous keratitis (1)
- Visual quality (1)
- cataract surgery (1)
- cataract surgery workflow (1)
Institut
- Medizin (3)
Purpose: To report a case of autoimmune keratitis in a patient with mycobacterium tuberculosis (MBT).
Methods: An 84-year-old male with pulmonary tuberculosis (TB) was admitted with chronic, non-healing bilateral ulcerations of the inferior peripheral cornea associated with stromal and subconjunctival nodules.
Results: Clinical examination revealed circumscribed peripheral corneal ulceration with whitish nodules in adjacent stromal and subconjunctival tissue. Microbiological cultures of the corneal tissue were negative for MBT and other microbial pathogens; however, enzyme-linked immunosorbent assay (ELISA) of blood and corneal samples showed significantly elevated levels of IgM and IgA against MBT. In addition to systemic anti-tuberculosis therapy, the patient was treated topically with Polyspectran® eye drops, Dexamethasone eye drops, and Bepanthen® ointment, for 2 weeks. Both eyes showed dramatic improvement after 2 weeks.
Conclusion: The present report demonstrates that MBT is able to initiate delayed autoimmune response within the corneal tissue during an intensive phase of anti-tuberculosis treatment.
Background: To determine whether there is a significant saving of time when using a digital cataract workflow for digital data transfer compared to a manual approach of biometry assessment, data export, intraocular lens calculation, and surgery time.
Methods: In total, 48 eyes of 24 patients were divided into two groups: 24 eyes were evaluated using a manual approach, whereas another 24 eyes underwent a full digital lens surgery workflow. The primary variables for comparison between both groups were the overall time as well as several time steps starting at optical biometry acquisition until the end of the surgical lens implantation. Other outcomes, such as toric intraocular lens misalignment, reduction of cylinder, surgically induced astigmatism, prediction error, and distance visual acuity were measured.
Results: Overall, the total diagnostic and surgical time was reduced from 1364.1 ± 202.6 s in the manual group to 1125.8 ± 183.2 s in the digital group (p < 0.001). The complete time of surgery declined from 756.5 ± 82.3 s to 667.3 ± 56.3 (p < 0.0005). Compared to the manual approach of biometric data export and intraocular lens calculation (76.7 ± 12.3 s) as well as the manual export of the reference image to a portable external storage device (26.8 ± 5.5 s), a highly significant saving of time was achieved (p < 0.0001).
Conclusions: Using a software-based digital approach to toric intraocular lens implantation is convenient, more efficient, and thus more economical than a manual workflow in surgery practice.
Purpose: To investigate short-term (3 months follow-up) changes in visual quality following Descemet membrane endothelial keratoplasty (DMEK) for Fuchs endothelial dystrophy (FED). Methods: In this prospective institutional case series, 51 patients that underwent DMEK for FED were included. Assessment included the Quality of Vision (QoV) questionnaire preoperatively, at 1 month, and 3 months after surgery. Secondary outcome measures were anterior segment parameters acquired by Scheimpflug imaging, corrected distance visual acuity (CDVA), and endothelial cell density (ECD). Results: Glare, hazy vision, blurred vision, and daily fluctuation in vision were the symptoms mostly reported preoperatively. All symptoms demonstrated a significant reduction of item scores for severity, frequency, and bothersome in the course after DMEK (P < 0.01). Glare and fluctuation in vision remained to some extent during the follow-up period (median score = 1). Preoperatively, corneal densitometry correlated moderately to weakly with severity of hazy vision (rs = 0.39; P = 0.03) and frequency (rs = 0.26; P = 0.02) as well as severity (rs = 0.27; P = 0.03) of blurry vision. CDVA and central corneal thickness (CCT) did not correlate with visual complains. Conclusions: Following DMEK for FED, patient-reported visual symptoms assessed by the QoV questionnaire represent a useful tool providing valuable information on the impact of DMEK on visual quality that cannot be directly estimated by morphological parameters and visual acuity only.