Refine
Year of publication
Document Type
- Article (38)
- Part of Periodical (2)
Has Fulltext
- yes (40)
Is part of the Bibliography
- no (40)
Keywords
- Herb induced liver injury (4)
- Magnetic resonance imaging (3)
- Algorithms (2)
- Bone density (2)
- Cancer (2)
- Causality assessment (2)
- Drug hepatotoxicity (2)
- Drug induced liver injury (2)
- Hepatocellular carcinoma (2)
- Herbal hepatotoxicity (2)
- Multidetector computed tomography (2)
- Osteoporosis (2)
- Pelargonium sidoides (2)
- Spine (2)
- Tomography (x-ray computed) (2)
- 19F (1)
- Adelgidae (1)
- Age determination by skeleton (1)
- Aphids (1)
- Applied vegetation science (1)
- Artificial intelligence (1)
- Attention-Deficit/Hyperactivity Disorder (ADHD) (1)
- Biomarkers (1)
- Bone diseases, Metabolic (1)
- Bone marrow (1)
- Brain tumor (1)
- Breast tumors (1)
- Bryophyta (1)
- CIOMS (1)
- COVID-19 (1)
- CT dual-energy computed tomography (1)
- Calcium (1)
- Cancer genetics (1)
- Cancer genomics (1)
- Cell binding (1)
- Cell staining (1)
- Centers for Disease Control and Prevention (1)
- Cerebral toxoplasmosis HIV (1)
- Cinarinae (1)
- Climate-change ecology (1)
- Cohort studies (1)
- Community ecology (1)
- Computed tomography, X-ray (1)
- Contingent Negative Variation, CNV (1)
- Continuous Performance Test, CPT (1)
- Contrast agent (1)
- Council for International Organizations of Medical Sciences (1)
- Cue-P3 (1)
- CyberKnife robotic radiosurgery (1)
- DNA-PAINT (1)
- DSM (1)
- Delivery quality assurance (1)
- Diagnosis (1)
- Diagnostic imaging (1)
- Drugs (1)
- Dry Grassland Working Group (1)
- Dual-energy computed tomography (1)
- Ecological modelling (1)
- Ecological networks (1)
- Edema (1)
- Event related potentials (1)
- FBS (1)
- Festuco-Brometea (1)
- Flow cytometry (1)
- Food and Drug Administration (1)
- Genomic instability (1)
- Glioma (1)
- Hawaii Department of Health (1)
- Heart transplantation (1)
- Herbalife products (1)
- Herbs (1)
- Herniated disk (1)
- Honolulu Queen’s Medical Center (1)
- Image processing (1)
- Image processing (computer-assisted) (1)
- Immunology (1)
- Intervertebral disc displacement (1)
- Kava (1)
- Ki67 transgenic c‐myc/TGFα mice (1)
- Koelerio-Corynephoretea (1)
- Kupffer cells (1)
- Late presentation (1)
- Lipiodol (1)
- Liquid filled MicroLion ion chamber array (1)
- Macrophages (1)
- Mitomycin C (1)
- Molecular diagnostic testing (1)
- Molecular matched therapy (1)
- Molecular medicine (1)
- Molecular profiling (1)
- Mouse models (1)
- Necrotic area (1)
- Neurofeedback (1)
- Non-small cell lung cancer (1)
- Nordic aphids on conifers (1)
- Opportunistic infections (1)
- Osteoporotic fractures (1)
- OxyELITE Pro (1)
- PCP (1)
- Pelargonium sidoides questionable hepatotoxicity (1)
- Phantoms (imaging) (1)
- Pharmacovigilance (1)
- Pneumocystis jirovecii (1)
- Positron emission tomography (1)
- Pteridophyta (1)
- RNA (1)
- Radiology (1)
- Randomized Controlled Trial (1)
- Re-exposure (1)
- Registries (1)
- Response (1)
- Response control (1)
- Retrospective studies (1)
- Retrospective study (1)
- Slow Cortical Potentials, SCP (1)
- Spinal fractures (1)
- Stereotactic body radiation therapy (1)
- Survival (1)
- Sustained attention (1)
- TACE (1)
- Targeted therapy (1)
- Thorax (1)
- Tomography (1)
- Treatment (1)
- Tumor volume (1)
- Vasculitis (1)
- Virtual noncalcium reconstructions (1)
- X-ray computed (1)
- angiography (1)
- clock genes (1)
- colour images (1)
- computer-assisted (1)
- conference report (1)
- diagnostic imaging (1)
- fluorine (1)
- fragment-based screening (1)
- hepatocellular carcinoma (1)
- identification (1)
- identification keys (1)
- in vivo dosimetry (1)
- liver (1)
- multidetector computed tomography (1)
- photographs (1)
- portal vein (1)
- proteins (1)
- radiation dosage (1)
- radiation dosimetry (1)
- radiation protection (1)
- restoration ecology (1)
- thrombosis (1)
- γ‐H2AX (1)
Institute
- Medizin (33)
- Biochemie, Chemie und Pharmazie (1)
- Biodiversität und Klima Forschungszentrum (BiK-F) (1)
- Biowissenschaften (1)
- Geographie (1)
- Institut für Ökologie, Evolution und Diversität (1)
- Physik (1)
- Sonderforschungsbereiche / Forschungskollegs (1)
- Zentrum für Biomolekulare Magnetische Resonanz (BMRZ) (1)
Background and aim. In the fall of 2013, the US Centers for Disease Control and Prevention (CDC) published a preliminary report on a cluster of liver disease cases that emerged in Hawaii in the summer 2013. This report claimed a temporal association as sufficient evidence that OxyELITE Pro (OEP), a dietary supplement (DS) mainly for weight loss, was the cause of this mysterious cluster. However, the presented data were inconsistent and required a thorough reanalysis.
Material and methods. To further investigate the cause(s) of this cluster, we critically evaluated redacted raw clinical data of the cluster patients, as the CDC report received tremendous publicity in local and nationwide newspapers and television. This attention put regulators and physicians from the medical center in Honolulu that reported the cluster, under enormous pressure to succeed, risking biased evaluations and hasty conclusions.
Results. We noted pervasive bias in the documentation, conclusions, and public statements, also poor quality of case management. Among the cases we reviewed, many causes unrelated to any DS were evident, including decompensated liver cirrhosis, acute liver failure by acetaminophen overdose, acute cholecystitis with gallstones, resolving acute hepatitis B, acute HSV and VZV hepatitis, hepatitis E suspected after consumption of wild hog meat, and hepatotoxicity by acetaminophen or ibuprofen. Causality assessments based on the updated CIOMS scale confirmed the lack of evidence for any DS including OEP as culprit for the cluster.
Conclusions. Thus, the Hawaii liver disease cluster is now best explained by various liver diseases rather than any DS, including OEP.
The diagnosis of drug induced liver injury (DILI) is based primarily on the exclusion of alternative causes. To assess the frequency of alternative causes in initially suspected DILI cases, we searched the Medline database with the following terms: drug hepatotoxicity, drug induced liver injury, and hepatotoxic drugs. For each term, we used the first 100 publications. We reviewed references, selected those reports relevant to our study, and retrieved finally 15 publications related to DILI and alternative causes. A total of 2,906 cases of initially assumed DILI were analyzed in these 15 publications, with diagnoses missed in 14% of the cases due to overt alternative causes. In another 11%, the diagnosis of DILI could not be established because of confounding variables. Alternative diagnoses included hepatitis B, C, and E, CMV, EBV, ischemic hepatitis, autoimmune hepatitis, primary biliary cirrhosis, primary sclerosing cholangitis, hemochromatosis, Wilson’s disease, Gilbert’s syndrome, fatty liver, non alcoholic steatohepatitis, alcoholic liver diseases, cardiac and thyroid causes, rhabdomyolysis, polymyositis, postictal state, tumors, lymphomas, chlamydial and HIV infections. Causality assessment methods applied in these 15 publications were the CIOMS (Council for International Organizations of Medical Sciences) scale alone (n = 5) or combined with the Maria and Victorino (MV) scale (n = 1), the DILIN (Drug-Induced Liver Injury Network) method (n = 4), or the Naranjo scale (n = 1); the qualitative CIOMS method alone (n = 3) or combined with the MV scale (n = 1). In conclusion, alternative diagnoses are common in primarily suspected DILI cases and should be excluded early in future cases, requiring a thorough clinical and causality assessment.
Herbal hepatotoxicity is a rare but highly disputed disease because numerous confounding variables may complicate accurate causality assessment. Case evaluation is even more difficult when the WHO global introspection method (WHO method) is applied as diagnostic algorithm. This method lacks liver specificity, hepatotoxicity validation, and quantitative items, basic qualifications required for a sound evaluation of hepatotoxicity cases. Consequently, there are no data available for reliability, sensitivity, specificity, positive and negative predictive value. Its scope is also limited by the fact that it cannot discriminate between a positive and a negative causality attribution, thereby stimulating case overdiagnosing and overreporting. The WHO method ignores uncertainties regarding daily dose, temporal association, start, duration, and end of herbal use, time to onset of the adverse reaction, and course of liver values after herb discontinuation. Insufficiently considered or ignored are comedications, preexisting liver diseases, alternative explanations upon clinical assessment, and exclusion of infections by hepatitis A-C, cytomegalovirus (CMV), Epstein-Barr virus (EBV), herpes simplex virus (HSV), and varicella zoster virus (VZV). We clearly prefer as alternative the scale of CIOMS (Council for International Organizations of Medical Sciences) which is structured, quantitative, liver specific, and validated for hepatotoxicity. In conclusion, causality of herbal hepatotoxicity is best assessed by the liver specific CIOMS scale validated for hepatotoxicity rather than the obsolete WHO method that is liver unspecific and not validated for hepatotoxicity. CIOMS based assessments will ensure the correct diagnosis and exclude alternative diagnosis that may require other specific therapies.
Purpose: High precision radiosurgery demands comprehensive delivery-quality-assurance techniques. The use of a liquid-filled ion-chamber-array for robotic-radiosurgery delivery-quality-assurance was investigated and validated using several test scenarios and routine patient plans.
Methods and material: Preliminary evaluation consisted of beam profile validation and analysis of source–detector-distance and beam-incidence-angle response dependence. The delivery-quality-assurance analysis is performed in four steps: (1) Array-to-plan registration, (2) Evaluation with standard Gamma-Index criteria (local-dose-difference ⩽ 2%, distance-to-agreement ⩽ 2 mm, pass-rate ⩾ 90%), (3) Dose profile alignment and dose distribution shift until maximum pass-rate is found, and (4) Final evaluation with 1 mm distance-to-agreement criterion. Test scenarios consisted of intended phantom misalignments, dose miscalibrations, and undelivered Monitor Units. Preliminary method validation was performed on 55 clinical plans in five institutions.
Results: The 1000SRS profile measurements showed sufficient agreement compared with a microDiamond detector for all collimator sizes. The relative response changes can be up to 2.2% per 10 cm source–detector-distance change, but remains within 1% for the clinically relevant source–detector-distance range. Planned and measured dose under different beam-incidence-angles showed deviations below 1% for angles between 0° and 80°. Small-intended errors were detected by 1 mm distance-to-agreement criterion while 2 mm criteria failed to reveal some of these deviations. All analyzed delivery-quality-assurance clinical patient plans were within our tight tolerance criteria.
Conclusion: We demonstrated that a high-resolution liquid-filled ion-chamber-array can be suitable for robotic radiosurgery delivery-quality-assurance and that small errors can be detected with tight distance-to-agreement criterion. Further improvement may come from beam specific correction for incidence angle and source–detector-distance response.
In context of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), patients with certain comorbidities and high age, as well as male sex are considered to represent the risk group for severe course of disease. Corona-virus disease 2019 (COVID-19) typical CT-patterns include bilateral, peripheral ground glass opacity (GGO), septal thickening, bronchiectasis, consolidation as well as associated pleural effusion. We report a 77-year-old heart transplanted patient with confirmed COVID-19 infection and coronary heart disease, diabetes type II and other risk factors. Notably, only slight clinical symptoms were reported and repeated computed tomography (CT) scans showed an atypical course of CT findings during his hospitalization.
Highlights
• MRI and ultrasound provided significant correlations between findings suggestive of vasculitis and the final diagnosis.
• Careful selection of available imaging techniques is warranted considering the time course, location, and clinical history.
• Considering its moderate diagnostic power to distinguish tracer uptake, a holistic view of PET/CT findings is essential.
Abstract
Purpose: To assess the diagnostic value of different imaging modalities in distinguishing systemic vasculitis from other internal and immunological diseases.
Methods: This retrospective study included 134 patients with suspected vasculitis who underwent ultrasound, magnetic resonance imaging (MRI), or 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) between 01/2010 and 01/2019, finally consisting of 70 individuals with vasculitis. The main study parameter was the confirmation of the diagnosis using one of the three different imaging modalities, with the adjudicated clinical and histopathological diagnosis as the gold standard. A secondary parameter was the morphological appearance of the vessel affected by vasculitis.
Results: Patients with systemic vasculitis had myriad clinical manifestations with joint pain as the most common symptom. We found significant correlations between different imaging findings suggestive of vasculitis and the final adjudicated clinical diagnosis. In this context, on MRI, vessel wall thickening, edema, and diameter differed significantly between vasculitis and non-vasculitis groups (p < 0.05). Ultrasound revealed different findings that may serve as red flags in identifying patients with vasculitis, such as vascular occlusion or halo sign (p = 0.02 vs. non-vasculitis group). Interestingly, comparing maximal standardized uptake values from PET/CT examinations with vessel wall thickening or vessel diameter did not result in significant differences (p > 0.05).
Conclusions: We observed significant correlations between different imaging findings suggestive of vasculitis on ultrasound or MRI and the final adjudicated diagnosis. While ultrasound and MRI were considered suitable imaging methods for detecting and discriminating typical vascular changes, 18F-FDG PET/CT requires careful timing and patient selection given its moderate diagnostic accuracy.
This paper reports on Monte Carlo simulation results for future measurements of the moduli of time-like proton electromagnetic form factors, |GE | and |GM|, using the ¯pp → μ+μ− reaction at PANDA (FAIR). The electromagnetic form factors are fundamental quantities parameterizing the electric and magnetic structure of hadrons. This work estimates the statistical and total accuracy with which the form factors can be measured at PANDA, using an analysis of simulated data within the PandaRoot software framework. The most crucial background channel is ¯pp → π+π−,due to the very similar behavior of muons and pions in the detector. The suppression factors are evaluated for this and all other relevant background channels at different values of antiproton beam momentum. The signal/background separation is based on a multivariate analysis, using the Boosted Decision Trees method. An expected background subtraction is included in this study, based on realistic angular distribuations of the background contribution. Systematic uncertainties are considered and the relative total uncertainties of the form factor measurements are presented.
Chordomas are rare bone tumors with few therapeutic options. Here we show, using whole-exome and genome sequencing within a precision oncology program, that advanced chordomas (n = 11) may be characterized by genomic patterns indicative of defective homologous recombination (HR) DNA repair and alterations affecting HR-related genes, including, for example, deletions and pathogenic germline variants of BRCA2, NBN, and CHEK2. A mutational signature associated with HR deficiency was significantly enriched in 72.7% of samples and co-occurred with genomic instability. The poly(ADP-ribose) polymerase (PARP) inhibitor olaparib, which is preferentially toxic to HR-incompetent cells, led to prolonged clinical benefit in a patient with refractory chordoma, and whole-genome analysis at progression revealed a PARP1 p.T910A mutation predicted to disrupt the autoinhibitory PARP1 helical domain. These findings uncover a therapeutic opportunity in chordoma that warrants further exploration, and provide insight into the mechanisms underlying PARP inhibitor resistance.
This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95–23.01) to 2.36 μSv (IQR, 0.52–12.66) (−36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 μSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 μSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (−30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.